• Title/Summary/Keyword: Root fracture

Search Result 282, Processing Time 0.03 seconds

Stress Corrosion Cracking Lifetime Prediction of Spring Screw (스프링 체결나사의 응력부식균열 수명예측)

  • Koh, S.K.;Ryu, C.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.7-12
    • /
    • 2004
  • A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw.

  • PDF

Modification of Current Leak Before Break Criteria for Nuclear Piping System (원자력 발전소 배관에 대한 파단전누설 개념 적용기준의 수정)

  • Yu, Yeong-Jun;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1862-1871
    • /
    • 1996
  • The puopose of this paper is sto modify the current LBB criteria. The validity of current LBB criteria and current standard LBB analysis mehtod are evaluated using linear elastic fracture mechanics and elastic-plastic fracture mechanics. The results of evaluation demonstrate that the current LBB driteria are very conservative and some level of margins already exist in the standard LBB analysis method. Thus, the margin on load .root. and margin on crack size 2 can be eliminated to extend LBB application for the samller diameter pipe.

A Case of Root Canal Treatment and Crown Therapy on Fractured Canine Teeth of Lion (골절된 사자 견치의 근관치료 및 Crown 장착 1례)

  • 이기환;신남식;권수완;김양범;이은창;정성목;이충호;김완희;권오경
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.298-298
    • /
    • 2000
  • Seven years old male lion in Everland Zoo has three fractured canine tooth. To avoid the risk of a possible fracture with pulp exposure after restroration of largest abration defects, endodontic therapy was performed. The pulp chamber was filled with calcium hydroxide, zinc oxide cement and gutta percha. We also installed the Crown prosthesis was installed in fractured canine tooth to protect the tooth and to improve the cosmetics and function of the tooth. The lion could eat in one day and there were no any signs of dental problem. It is the obvious prophylactic procedure for wild animal is the inclusion of an oral examination at every opportunity to handle the animal. It is considered that crown prosthesis after endodontic therapy was useful for maintaining normal physiological function and for provention of additional fracture or complication.

  • PDF

Mechanics Evaluations of Stress Corrosion Cracking for Dissimilar Welds in Nuclear Piping System (원자력 배관 이종금속 용접부 웅력부식균열의 역학적 평가)

  • Park, Jun-Su;Na, Bok-Gyun;Kim, In-Yong
    • Proceedings of the KWS Conference
    • /
    • 2005.11a
    • /
    • pp.38-40
    • /
    • 2005
  • Fracture mechanics evaluation of stress corrosion cracking (SCC) in the dissimilar metal weld (DMW) for the nuclear piping system is performed; simulating the transition joint of the ferritic nozzle to austenitic safe-end fabricated with the Inconel Alloy A82/182 buttering and welds. Residual stresses in the DMW are computed by the finite element (FE) analyses Then, to investigate the SCC in the weld root under the combined residual and system operation stresses, the fracture mechanics parameters for a semi-elliptical surface crack are evaluated using the finite element alternating method (FEAM). As a result, it is found that the effect of weld residual stresses on the crack-driving forces is dominant, as high as three times or more than the operation stresses.

  • PDF

The Effect of Ganglion Impar Block for Neoplastic Perineal Pain with Coccygeal Fracture -A case report- (미골골절이 있는 암성 회음부통증 환자에 시행한 외톨이 교감신경절 차단 -증례 보고-)

  • Lee, Sung-Keun;Cha, Young-Deog;Suk, Min-Ho
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.250-253
    • /
    • 1997
  • The perineum is comprised of diverse anatomic structures with mixed sympathetic and somatic innervation. The coccyx is innervated by the coccygeal nerves and branches of the fifth sacral root. Recently, ganglion impar block has been introduced as an alternative means of managing intractable pain of sympathetic origin, coccygodynia by trauma, tenesmus and perineal hyperhydrosis. We managed a 59-year-old female patient who had suffered from perineal pain by metastasis of cervical cancer. Approach to impar ganglion through the anococcygeal ligament was impossible because her coccyx was hyperflexed anteriorly by old fracture. But we could perform ganglion impar block successfully by approach through the separation of sacrum and coccyx.

  • PDF

The Case Study on Cadmium Embrittlement Failure of High Strength Bolt (고강도 볼트 카드늄 취성파괴 사례연구)

  • Yoon, Young-In
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.769-774
    • /
    • 2010
  • It happened fractures on special bolt which supported main landing gear actuator up-lock rod of aircraft. Cracks were initiated mainly from the center hole and the external thread of the special bolt. To find out failure root causes, metallographic, fractographic analyses as well as test work were carried out. From the fractographic study by SEM work, fracture occurred by a brittle intergranular type failure. The fracture could be occurred primarily by solid-metal-induced embrittlement due to cadmium embrittler penetrated into the flaw existed after machining work for center hole and thread on the bolt during baking treatment processing to eliminate hydrogen. For its successful application, cadmium EP bolts require proper and adequate baking treatment after electroplating, and make no more drilled center hole on the bolt to prevent same failure.

Fracture resistance of ceramic brackets to arch wire torsional force (토오크 양에 따른 세라믹 브라켓의 파절 저항성)

  • Han, Jung-Heum;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.293-304
    • /
    • 2007
  • The purpose of this study was to estimate the fracture resistance of commercially available ceramic brackets to torsional force exerted from arch wires and to evaluate the characteristics of bracket fracture. Methods: Lingual root torque was applied to maxillary central incisor brackets with 0.022-inch slots by means of a $022\;{\times}\;028-inch$ stainless steel arch wire. A custom designed apparatus that attached to an Instron was used to test seven types of ceramic brackets (n = 15). The torque value and torque angle at fracture were measured. In order to evaluate the characteristics of failure, fracture sites and the failure patterns of brackets were examined with a Scanning Electron Microscope. Results: Crystal structure and manufacturing process of ceramic brackets had a significant effect on fracture resistance. Monocrystalline alumina (Inspire) brackets showed significantly greater resistance to torsional force than polycrystalline alumina brackets except InVu. There was no significant difference in fracture resistance during arch wire torsional force between ceramic brackets with metal slots and those without metal slots (p > 0.05). All Clarity brackets partially fractured only at the incisal slot base and the others broke at various locations. Conclusion: The fracture resistance of all the ceramic brackets during arch wire torsion appears to be adequate for clinical use.

Foraminal Synovial Cyst Associated with Ankylosing Spondylitis

  • Kim, Heyun-Sung;Ju, Chang-Il;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.54-56
    • /
    • 2011
  • Ankylosing spondylitis (AS) is frequently associated with inflammatory lesions of the spine and continuous fatigue stress fractures; however, an association with an intraspinal synovial cyst has not been previously reported. A 55-year-old man with a five year history of AS who presented with back pain and a right radiculopathy was admitted to the hospital. Five years previously, he underwent a percutaneous vertebroplasty for an osteoporotic L1 compression fracture, and was diagnosed with AS at that time. Plain radiographs showed aggravated kyphosis and a stress fracture through the ossified posterior element, below the prior vertebroplasty. Magnetic resonance images revealed a right foraminal cystic lesion at the L2-L3 level with effacement of the nerve root. A 1.6 cm cystic lesion that appeared to arise from the L2-L3 facet joint without direct communication was excised from the L2-L3 foramen. Pathological examination confirmed synovial cyst. The patient's symptoms resolved immediately after surgery except for a mild dysesthesia of the right leg. We report herein a rare case of foraminal synovial cyst associated with AS accompanying posterior element fracture with a review of literature.

Effect of N2/Ar flow rates on Si wafer surface roughness during high speed chemical dry thinning

  • Heo, W.;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.128-128
    • /
    • 2010
  • In this study, we investigated the evolution and reduction of the surface roughness during the high-speed chemical dry thinning process of Si wafers. The direct injection of NO gas into the reactor during the supply of F radicals from NF3 remote plasmas was very effective in increasing the Si thinning rate, due to the NO-induced enhancement of the surface reaction, but resulted in the significant roughening of the thinned Si surface. However, the direct addition of Ar and N2 gas, together with NO gas, decreased the root mean square (RMS) surface roughness of the thinned Si wafer significantly. The process regime for the increasing of the thinning rate and concomitant reduction of the surface roughness was extended at higher Ar gas flow rates. In this way, Si wafer thinning rate as high as $20\;{\mu}m/min$ and very smooth surface roughness was obtained and the mechanical damage of silicon wafer was effectively removed. We also measured die fracture strength of thinned Si wafer in order to understand the effect of chemical dry thinning on removal of mechanical damage generated during mechanical grinding. The die fracture strength of the thinned Si wafers was measured using 3-point bending test and compared. The results indicated that chemical dry thinning with reduced surface roughness and removal of mechanical damage increased the die fracture strength of the thinned Si wafer.

  • PDF

A STUDY ON THE FRACTURE MODES AND FAILURE LOADS OF THE VARIOUS TYPES OF RESTORATION FOR THE ENDODONTICALLY TREATED ANTERIOR TEETH (전치부 근관충전후 수복형태에 따른 파절형태 및 파단하중에 관한 연구)

  • Park, Young-Sook;Choi, Sung-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 1982
  • An endodontically treated tooth is likely to be brittle than a vital tooth. Internal structure of the tooth has been weakened due to a significant removal of dentin by coronal access, canal preparation. There are many controversies concerning with various methods of reinforcing an intact anterior tooth that has endodontic treatment. In this experiment, 128 extracted maxillary anterior teeth were endodontically treated, and prepared with 4 methods of restorations; Composite resin filling with zinc phosphate cement, composite resin filling without zinc phosphate cement, composite resin filling with post, and metal crown with post. An Instron testing machine was used to measure the fracture loads of the specimens. The means of the failure loads for the 4 groups were compared by F-test statistically and the failure modes were observed. The results were as follows; 1. There were no statistically significant difference between the failure loads of the four methods of restoration. 2. Teeth without post were fractured in a horizontal or oblique plane through upper or middle third of the root. 3. In the posted teeth, fractures were occurred around the post. 4. In the metal crowned teeth with post, the fracture were occurred around the post or coronal area.

  • PDF