• 제목/요약/키워드: Root canals

검색결과 439건 처리시간 0.027초

Endodontic treatment of maxillary lateral incisors with anatomical variations

  • Lee, Moon-Hwan;Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제38권4호
    • /
    • pp.253-257
    • /
    • 2013
  • Maxillary lateral incisors usually exhibit a single root with a single canal. However, maxillary lateral incisor teeth with unusual morphology of root canal system are frequently reported. These cases of variable root canal anatomy can be treated well by nonsurgical endodontic methods. A detailed description of root canal morphology is fundamental for successful endodontic treatment. Treatment using an operating microscope, radiographs from different angles, and cone-beam computerized tomography (CBCT) can produce more predictable endodontic outcomes.

주파수의존형 전자근관장측정기의 정확도에 관한 연구 (The accuracy of the frequency dependent type apex locator)

  • 박주현;노병덕;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF

모조 레진블락 근관에서 LightSpeed, ProTaper 및 Hybrid technique의 성형 효율 비교 (Comparison of shaping ability using LightSpeed, ProTaper and Hybrid technique in simulated root canals)

  • 강순일;곽상원;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제47권7호
    • /
    • pp.444-454
    • /
    • 2009
  • The purpose of this study was to compare the shaping abilities of LightSpeed, ProTaper-Universal, and hybrid technique using S-series of ProTaper-Universal and LigthSpeed. The 72 simulated root canals of J-shape were used and classified as flowing 3 groups according to the instrumentation methods; Group P of 24 canal blocks were prepared with ProTaper-Universal, Group L was prepared with LightSpeed, and Group H was prepared with hybrid technique (initial shaping with ProTaper-Universal SI and S2 and apical shaping with LightSpeed from #25 to #50). A second-year resident of Endodontic department prepared the resin block canals to apical size #50 (F5 in Group P). The time lapses for instrumentation and the reduction of root canal curvature after shaping were measured. The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the increased canal width and apical centering ratio. The results were as followings: Group Land H showed significant less instrumentation time than Group P (p < 0.05). The ProTaper system showed greater reduction of root canal curvature and working length diminishment than other methods (p < 0.05). LightSpeed system showed best canal curvature preserving characteristics. The Group P had greater instrumented widths at all levels examined (p < 0.05). Group L and Group H showed lower centering ratio (ability to preserve the canal center; the lower ratio means the better canal center preservation) than Group P (p < 0.05). Group H had the lowest centering ratio at the 1 mm level.

  • PDF

Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

  • Meireles, Daniely Amorin;Bastos, Mariana Mena Barreto;Marques, Andre Augusto Franco;Garcia, Lucas Da Fonseca Roberti;Sponchiado, Emilio Carlos Junior
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.167-171
    • /
    • 2013
  • Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

다양한 엔진 구동형 파일의 근관 성형 능력 비교 (SHAPING ABILITY OF NICKEL-TITANIUMROTARY FILES)

  • 박완기;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.44-50
    • /
    • 2004
  • This study compared the shaping ability of nickel-titanium rotary files with different rake angle and radial land. The nickel-titanium files used in this study were Profile(Dentsply, Maillefer, Ballaigues, Switzerland), Hero 642(Micromega, Besancon, France) and K3 (SybronEndo, Glendora, Ca, USA) file. Resin blocks substituted for root canals. 36 resin blocks were divided into 3 groups with 12 canals each The time for canal preparation was recorded. The images of pre- and postoperative resin canal were scanned and those were superimposed Amounts of canal deviation, total canal widths, inner canal widths, and outer canal widths were measured at apical 1, 2 ,3, 4, 5, 6, and 7mm levels. The amount of canal deviation was the smallest in Profile group , and the time far canal preparation was the shortest in Hero 642 group. K3 group resulted in competent characteristics in both measurements. Positive rake angle seemed to result in fast shaping of root canal and radial land guide the instrument in center of the canals and around curvatures. Radial land also tended to reduce the sense of screwing into the root canal. The proper selection of the nickel-titanium fie based on the knowledge about file design is needed for the safer, simpler and faster root canal therapy.

주파수의존 근관장 측정기가 습윤한 근관내에서 근첨을 인지하게 되는 원리에 관한 연구 (A STUDY ON THE MECHANISM BY WHICH THE FREQUENCY-DEPENDENT APEX LOCATOR DETECTS THE APEX OF THE ROOT IN MOIST CANALS)

  • 박한수;유현미;오태석
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.676-681
    • /
    • 1998
  • The purpose of this study is to explain theoretically the mechanism of the frequency-dependent apex locator which can detect the apex of the root in moist canals with blood or other conductible canal irrigants. The frequency-dependent apex locator is based on measuring the ratio of the two impedances of the two alternating currents with different frequencies. We analyzed the changes of the ratio between the two impedances by using differential calculus. Our analysis shows that : 1. When the file is in the moist canal, the ratio between the two impedances is almost constant. 2. As the file approaches the apex of the root, the ratio decreases sharply. By this mechanism, the frequency-dependent apex locator can detect the apex of the-root quite accurately in moist canals.

  • PDF

Tricalcium phosphate와 Vitapex가 치근단 조직에 미치는 영향에 관한 실험적 연구 (THE EFFECT OF THE TRICALCIUM PHOSPHATE AND VITAPEX ON THE DOGS' PERIAPICAL TISSUES)

  • 최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.71-84
    • /
    • 1989
  • The purpose of this study was to evaluate the effect of tricalcium phosphate and Vitapex on the dogs' periapical tissues. Twenty mandibular premolars from 5 healthy dogs were used for this study. After the animals were anesthetized intramuscularly, pulp chambers were open and pulp tissue was extirpated with a barbed broach and H-file. Then the working length of the root canal was measured with H-file and pulp tissue was completely removed. Before the actual canal filling, the root canals of twenty teeth have been experimentally infected with opening the pulp chamber for 5 weeks. Periapical radiographs of the experimental teeth were taken to monitor the periapical pathological condition. Each root apex of 20 premolars was perforated with engine reamer and the root canals were enlarged with No. 30-60 H-files. They were divided into treated as follows. Control group: The root canal was filled with gutta-percha. Experimental group 1: The canal was dried with sterile paper points and mixture of tricalcium phosphate and physiological saline was overfilled beyond the root apex with a lentulo spiral. Then the root canal was filled gutta-percha and lateral condensation and the pulp chamber was filled with Caviton. Experimental group 2: The root canals were overfilled with Vitapex and were treated in the same manner as those in experimental group 1 At 1,2,3, and 8 weeks after experiment, the periapical tissues including the alveolar bone were fixed with 10% formalin solution for I week and decalcified with Plank-Rycho solution for 5 weeks. The specimens were embedded in paraffin and serial sections were cut into a thickness of 6 ${\mu}m$ at the plane of the root apex. Hematoxyline-eosin and Masson's trichrome stain were made for the histo-pathological examinations. The results were as follows: 1. Ingrowth of collagen fiber was observed from 1 week in control group and experimental groups. 2. The rate of bone formation of experimental group 1 was accelerated more than that of experimental group 2. 3. Resorption of cementum was seen in control group, but apposition of cementum was seen in experimental groups.

  • PDF

근관치료시(根管治療時) 근단공(根端孔)의 위치(位置)에 관(關)한 X-선학적(線學的) 고찰(考察) (RADIOGRAPHIC STUDY OF THE POSITION OF APICAL FORAMEN IN ENDODONTIC THERAPY.)

  • 임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제5권1호
    • /
    • pp.35-40
    • /
    • 1979
  • The author observed thy actual position of apical foramen and the radiographic appearance of files when the files were filled through canals to the external surface of apical foramen in 280 canals of extracted teeth. All the teeth were radiographed by bisecting technic and once again Walton's projection was employed on mandibular molars. The results were as followings. 1. Sixty five percents of 280 canals were actually classed as having foramina deviant from true apex of root. 2. 160 of 280 canals(Fifty seven percents) appeared to be filled short of apex on the radiograph. 3. When Walton's projection was employed to open up two mesial canals of mandibular molars and compared to straight-on projection, twelve of 120 canals Ten percent appeared to be different in radiographic appearence.

  • PDF

Assessment of endodontically treated teeth by using different radiographic methods: an ex vivo comparison between CBCT and other radiographic techniques

  • Demiralp, Kemal Ozgur;Kamburoglu, Kivanc;Gungor, Kahraman;Yuksel, Selcen;Demiralp, Gokcen;Ucok, Ozlem
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.129-137
    • /
    • 2012
  • Purpose: To compare different radiographic methods for assessing endodontically treated teeth. Materials and Methods: Root canal treatments were applied in 120 extracted mandibular teeth, which were divided into four groups: (1) ideal root canal treatment (60 teeth), (2) insufficient lateral condensation (20 teeth), (3) root canals filled short of the apex (20 teeth), (4) overfilled root canal treatment (20 teeth). The teeth were imaged using intraoral film, panoramic film, digital intraoral systems (CCD and PSP), CCD obtained with portable X-ray source, digital panoramic, and CBCT images obtained at 0.3 $mm^3$ and 0.2 $mm^3$ voxel size. Images were evaluated separately by three observers, twice. Kappa coefficients were calculated. The percentage of correct readings obtained from each modality was calculated and compared using a t-test (p<0.05). Results: The intra-observer kappa for each observer ranged between 0.327 and 0.849. The inter-observer kappa for each observer for both readings ranged between 0.312 and 0.749. For the ideal root canal treatment group, CBCT with 0.2 $mm^3$ voxel images revealed the best results. For insufficient lateral condensation, the best readings were found with periapical film followed by CCD and PSP. The assessment of teeth with root canals filled short of the apex showed the highest percentage of correct readings by CBCT and CCD. For the overfilled canal treatment group, PSP images and conventional periapical film radiographs had the best scores. Conclusion: CBCT was found to be successful in the assessment of teeth with ideal root canal treatment and teeth with canals filled short of the apex.

엔진구동형 NiTi 파일의 근관성형효과 비교 (A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS)

  • 김보혜;최경규;박상혁;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.88-95
    • /
    • 2010
  • 이 연구의 목적은 4가지 엔진구동형 NiTi 기구의 근관성형력을 비교하는 것이다. 32개의 투명레진모형을 사용하여 파일의 단면도가 S자 형태이고 "single length"방법으로 근관성형을 시행하는 Mtwo와 crown-down 방법으로 근관성형을 하는 Profile, ProTaper Universal 및 K3로 근관성형을 하였다 (n = 8). 모든 근관은 한사람의 술자가 근단공 크기가 #30이 될 때까지 성형하였다. 기구 사용 전과 후 근관 모양을 디지털 영상을 기록하였고, 컴퓨터 영상 분석 프로그램(Expression Scanner와 Adobe Photoshop CS)으로 평가하였다. 다음과 같은 결론을 얻었다. 근첨으로부터 1, 2, 3, 4, 5, 6, 7 mm 떨어진 부위의 내측과 외측으로 삭제된 레진 양을 측정하였고, 자료는 SPSS법으로 비교 분석하였다. 1. 근관형성 시간은 Mtwo가 84.50초로 가장 짧았으며, 총 작업시간은 K3가 269.37초로 가장 길었다(p < 0.05). 2. 기구의 변형과 파절은 모든 구동형 NiTi 파일에서 발생하지 않았다. 3. 근관 내측 폭경의 변화는 Profile이 1, 2 mm 부위를 제외한 다른 부위에서 가장 적었으며, ProTaper Universal은 모든 부위에서 가장 많았다(p < 0.05). 4. 근관 외측 폭경의 변화는 Mtwo이 1 mm 부위를 제외한 모든 부위에서 가장 적었으며, Profile은 3, 4 mm 부위에서 가장 많았다(p < 0.05). ProTaper Universal와 K3는 1, 2, 6, 7 mm 부위에서 가장 많았다(p < 0.05). 5. 근관중심변위율(centering ratio)은 Profile이 1, 4, 5, 6 mm 부위에서 가장 적었다(p < 0.05). 이상의 결과, 구동성 NiTi 파일을 이용한 만곡 근관의 근관형성은 치경부는 ProTaper와 같은 삭제력이 높은 파일을 사용하는 것이 근관 입구를 효과적으로 넓히고 더 나은 taper를 형성하며, 근단부는 Profile과 같은 근관 중심 변위가 적은 파일을 사용하는 것이 근관형성 시간을 단축하고 근단부의 근관 변형(transportation)을 줄일 수 있다고 판단된다.