• 제목/요약/키워드: Root canal

검색결과 891건 처리시간 0.029초

Buckling resistance, torque, and force generation during retreatment with D-RaCe, HyFlex Remover, and Mtwo retreatment files

  • Yoojin Kim ;Seok Woo Chang;Soram Oh
    • Restorative Dentistry and Endodontics
    • /
    • 제48권1호
    • /
    • pp.10.1-10.9
    • /
    • 2023
  • Objectives: This study compared the buckling resistance of 3 nickel-titanium (NiTi) retreatment file systems and the torque/force generated during retreatment. Materials and Methods: The buckling resistance was compared among the D-RaCe (DR2), HyFlex Remover, and Mtwo R25/05 retreatment systems. J-shaped canals within resin blocks were prepared with ProTaper NEXT X3 and obturated by the single-cone technique with AH Plus. After 4 weeks, 4 mm of gutta-percha in the coronal aspect was removed with Gates-Glidden drills. Retreatment was then performed using DR1 (size 30, 10% taper) followed by DR2 (size 25, 4% taper), HyFlex Remover (size 30, 7% taper), or Mtrwo R25/05 (size 25, 5% taper) (15 specimens in each group). Further apical preparation was performed with WaveOne Gold Primary. The clockwise torque and upward force generated during retreatment were recorded. After retreatment, resin blocks were examined using stereomicroscopy, and the percentage of residual filling material in the canal area was calculated. Data were analyzed using 1-way analysis of variance with the Tukey test. Results: The HyFlex Remover files exhibited the greatest buckling resistance (p < 0.05), followed by the Mtwo R25/05. The HyFlex Remover and Mtwo R25/05 files generated the highest maximum clockwise torque and upward force, respectively (p < 0.05). The DR1 and DR2 files generated the least upward force and torque (p < 0.05). The percentage of residual filling material after retreatment was not significantly different between file systems (p > 0.05). Conclusions: NiTi retreatment instruments with higher buckling resistance generated greater clockwise torque and upward force.

Effect of irrigation protocols on smear layer removal, bond strength and nanoleakage of fiber posts using a self-adhesive resin cement

  • Rodrigo Stadler Alessi;Renata Terumi Jitumori ;Bruna Fortes Bittencourt;Giovana Mongruel Gomes ;Joao Carlos Gomes
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.28.1-28.13
    • /
    • 2023
  • Objectives: This study aimed to investigate the effect of the application method of 2% chlorhexidine (CHX) and its influence on the adhesion of fiberglass posts cemented with a self-adhesive resin cement. Materials and Methods: Sixty human mandibular premolars were endodontically treated and divided into 5 groups (n = 12), according to the canal irrigant and its application method: 2 groups with conventional syringe irrigation (CSI)-2.5% sodium hypochlorite (NaOCl) (control) and 2% CHX- and 3 groups with 2% CHX irrigation/activation-by passive ultrasonic irrigation (PUI), Easy Clean file, and XP-Endo Finisher file. Two roots per group were evaluated for smear layer (SL) removal by scanning electron microscopy. For other roots, fiber posts were luted using a self-adhesive resin cement. The roots were sectioned into 6 slices for push-out bond strength (BS) (7/group) and nanoleakage (NL) (3/group). Data from SL removal were submitted to Kruskal-Wallis and Student-Newman-Keuls tests (α = 0.05). Data from BS and NL were evaluated by 2-way analysis of variance and Tukey's test (α = 0.05). Results: For SL removal and BS, the CHX irrigation/activation promoted better values than CSI with CHX (p < 0.05), but it was not significantly different from CSI with NaOCl (p > 0.05). For NL, the lowest values were obtained by the chlorhexidine irrigation/activation groups (p < 0.05). Conclusions: Active 2% CHX irrigation can be used to improve the post space cleaning and adhesion before fiber post cementation with self-adhesive resin cements.

Modified Continuous Wave Technique을 이용한 근관충전시 형성된 치근단 크기가 치근단 폐쇄에 미치는 영향 (EVALUATION OF THE INFLUENCE OF APICAL SIZES ON THE APICAL SEALING ABILITY OF THE MODIFIED CONTINUOUS WAVE TECHNIQUE)

  • 류무현;정일영;이승종;신수정;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.66-75
    • /
    • 2008
  • 본 연구에서는 근관형성의 치근단 크기가 근관 충전의 치근단 폐쇄에 미치는 영향에 대해 알아보고자 하였다. 36개의 단근관, 단근치를 대상으로 3가지 치근단 크기 (Master apical file : #25, #40, #60)에 따라 3가지 실험군으로 나누어 $Profile^{(R)}$$LightSpeed^{(R)}$를 이용하여 근관을 확대하고, Modified continuous wave technique으로 근관충전을 시행하였다. 미세누출의 측정을 위해 실험군당 10개의 치아를 1주일간 India ink에 넣어 색소 침투를 일으키고 치아를 투명화시켜 미세누출의 정도를 측정하였다. 미세누출에 치근단 크기가 미치는 영향을 분석하기 위하여 Kruskal-Wallis one-way ANOVA를 시행하였고, 사후 검정을 위하여 Student-Newman-Keuls method를 시행하였다. 또한, 치아 단면의 형태를 관찰하기 위하여 색소 침투까지 실행된 각 실험군당 2개의 치아를 근첨 1 mm에서 4 mm까지 1 mm간격으로 수평 절단하고 사진 촬영하였다. 각 실험군에서 측정된 미세누출양을 Krustal-Wallis one-way ANOVA에서 분석한 결과 치근단 크기는 유의성 있게 (P < 0.05) 미세누출에 영향을 미쳤으며 치근단 크기가 클수록 미세누출의 평균간과 표준편차 값은 감소하는 경향을 보였다. Student-Newman-Keuls method를 통한 사후 검정에서 치근단 크기가 #25 - #40, #25 - #60에서 유의 한 차이를 보였으며 #40 - #60간에는 통계적인 유의차는 없었다. 단면형태에서는 대부분의 치아에서 난원형의 근관 형태를 관찰 할 수 있었고, 치근단의 크기가 작을수록 성형된 근관에 불규칙한 내면이 존재하였고 gutta-percha나 sealer로 충전되지 않는 recess의 면적이 증가함을 알 수 있었으며 이러한 recess는 미세누출의 통로가 됨을 확인 할 수 있었다. 본 연구 결과, Modified continuous wave technique으로 근관충전시 근관 형성된 치근단 크기가 커질수록 보다 일관되고 성공적 인 결과를 예상할 수 있는 근관충전을 시행할 수 있음을 알 수 있었다.

차아염소산나트륨과 클로르헥시딘의 반응침전물 형성방지를 위한 여러 가지 근관세척 방법의 비교 (THE COMPARISON OF DIFFERENT CANAL IRRIGATION METHODS TO PREVENT REACTION PRECIPITATE BETWEEN SODIUM HYPOCHLORITE AND CHLORHEXIDINE)

  • 최문선;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제35권2호
    • /
    • pp.80-87
    • /
    • 2010
  • 이 실험의 목적은 NaOCl과 CHX의 혼합사용 시, 발생하는 침전물의 형성을 막기 위해 두 용액간의 접촉을 줄일 수 있는 여러 가지 방법을 비교하고, 관찰된 침전물의 원소를 분석하는 것이다. 발거된 50개의 단근치를 사용하였으며 2.5% NaOCl을 이용하여 .04 taper ProFile #40까지 근관형성 하였다. 치아는 다음과 같은 근관세척 방법에 따라 4개의 실험군과 1개의 대조군으로 나누었다; 대조군: 2.5% NaOCl, 1군: 2.5% NaOCl + 2% CHX, 2군: 2.5% NaOCl + paper points + 2% CHX, 3군: 2.5% NaOCl + .04/#45 근관확대 + 2% CHX, 4군: 2.5% NaOCl +95% alcohol+ 2% CHX. 근관세척 후 치아를 양분하고 치관부, 중간부, 치근부 세부위로 나누어 전계 방사형 주사 전자현미경을 통하여 잔사 비율, 개방 상아세관 비율, 상아세관 내 물질의 원소분석을 시행하였다. 실험결과, 실험군 사이에 잔사비율과 개방된 상아세관 비율 비교에서 통계학 적으로 유의할 만한 차이는 나타나지 않았다. 1 군의 한 시편에서 C의 함유량이 높게 나타났으며 N과 Cl도 함께 검출되어 para-chloraniline으로 추정되며, 1 군의 다른 시편과 나머지 실험군에서는 O, P, C, Ca의 순으로 함유량이 높은 것으로 나타나 수산화인회석으로 추정된다. NaOCl 세척 후 바로 CHX 세척을 한 군에서 PCA로 의심되는 물질이 검출된 바, 두 용액의 직접적인 접촉을 피하기 위해 주의가 필요하며, 본 실험에 사용된 여러 근관 세척방법 이용 시 침전물의 형성을 예방할 수 있을 것이다.

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Fontenele, Rocharles Cavalcante;Mancini, Arthur Xavier Maseti;Freitas, Deborah Queiroz;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups(P>0.05). Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

유치와 영구치의 외상 양상 및 치료에 대한 후향적 연구 (A Retrospective Study of the Pattern and Treatment of Traumatic Dental Injury to Primary and Permanent Teeth)

  • 김유정;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제41권4호
    • /
    • pp.314-321
    • /
    • 2014
  • 본 연구는 치아 외상의 양상과 외상 후 초진 시기의 지연이 치료에 미치는 영향에 대해 알아보고자, 2009년 1월부터 2013년 12월까지 전남대학교 치과병원 소아치과에 치아 외상을 주소로 내원한 환자 378명(외상 치아 940개)을 대상으로 기록을 조사하여 다음과 같은 결과를 얻었다. 외상의 빈도는 남자가 여자보다 2배 더 높았다. 전체 외상의 원인은 넘어짐(36.5%)이 가장 많았고, 상악 중절치(66.9%)가 가장 많이 영향을 받았다. 유치에서 가장 흔한 외상 유형은 아탈구(43.9%)였고, 영구치에서는 단순 치관파절(30.9%)이었다. 전체 환자의 10%만이 외상 후 1시간 이내에 치과에 내원하였다. 유치에서 가장 흔한 초진 시 처치는 경과관찰(53.2%)이었고, 영구치는 근관치료(27.3%)였다. 영구치에서 초진 시기의 경과에 따라 근관치료 비율은 증가하였다. 이는 외상 후 초진 시기가 늦어질수록 치수가 생활력을 잃을 가능성이 높아진다는 것을 알려준다.

열연화주입형 gutta percha와 resilon의 유변학적 특성 (Rheological characterization of thermoplasticized injectable gutta percha and resilon)

  • 장주혜;백승호;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.377-384
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 열연화주입형 gutta percha와 resilon의 온도 변화에 따른 점탄성 변화를 관찰하고 조작성을 비교하기 위함이다. 연구 재료 및 방법: Obtura-II 시스템을 이용하여 세 종류의 gutta percha와 resilon을 $140^{\circ}C$$200^{\circ}C$로 가열한 후 사출 온도를 측정하였다. 점도계를 이용하여 온도 변화에 따른 재료들의 점탄성 특성(전단탄성계수, G'; 전단점성계수, G"; 손실 탄젠트, tan${\delta}$; 복소점도, ${\eta}^*$)을 관찰하였다. 점도계와 차동주사열측정기(DSC)로 재료들의 상전이 온도를 측정하였고 가압법으로 $60^{\circ}C$$40^{\circ}C$에서 재료들의 점조도를 비교하였다. 결과: 세 종의 gutta perchas는 온도에 따라 서로 다른 점탄성 특성을 나타냈다. $40-50^{\circ}C$에서 연화된 재료의 고체화 상변이가 일어났고, 점도계와 DSC로 측정된 상변이 시작 온도는 유사하였다. 상변이 시작 온도와 가압 시 점조도는 재료들마다 차이를 보였다(p < 0.05). Resilon은 gutta percha와 비슷한 유변학적 특성을 보였다. 결론: 열연화된 근관충전재는 냉각과정 동안 유변학적 특성의 변화를 나타냈고 재료들마다 서로 다른 점탄성 특성은 근관 내주입 시와 충전 시 서로 다른 조작성을 보임을 알 수 있다.

소아에서의 Garre 골수염 (GARRE'S OSTEOMYELITIS IN CHILDREN)

  • 우세은;김영진;김현정;남순현
    • 대한소아치과학회지
    • /
    • 제38권4호
    • /
    • pp.413-420
    • /
    • 2011
  • Garre 골수염은 혈류 순환 및 영양 공급의 장애로 골이 괴사되거나, 세균 감염이 증가되면 발생한다. Garre 골수염은 치수나 치주 감염에서 시작된 치성계 감염과 이의 진행에 따른 골막 하 농양이 주요 원인이 되며, 외상으로 인한 악골의 복합 골절시 2차 감염, 국소적인 치은의 외상에 의해서도 발생할 수 있다. 상악에서보다 하악에서 많이 발생되며 호발 부위는 하악 제1대구치이다. 임상증상으로 이환 부위의 하악골은 팽창되어 있으나 구강점막은 정상적 색조를 가지며 안면 불균형을 나타낸다. 방사선사진 상 심한 우식증을 가진 치아의 치근단 병소를 관찰할 수 있으며, 자극을 받는 골조직 부위의 치밀골 증가로 골수강은 좁아지거나 폐쇄되며 외양이 불규칙하게 나타난다. 치료 방법으로는 항생제의 투여, 원인치의 발치 또는 근관치료, 절개 및 배농술 등이 알려져 있다. 본 증례는 15세 이하의 소아환자에서 악골 골수염이 발생한 경우, 장기적인 항생제 투여나 항생제 투여 및 근관 치료를 병용하여 성공적으로 치료된 증례이다. 소아 환자의 경우 성인에 비하여 증상이 경미하므로 주의 깊은 병력 청취와 임상 검사를 통한 진단이 요구되며, 증상이 사라진 경우에도 재발을 방지하기 위하여 장기간의 추적 검사가 요구된다.

Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교 (Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block)

  • 윤민정;송민주;신수정;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.59-65
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 서로 다른 기하학적 형태를 가진 3가지 Ni-Ti 파일, 즉 K3, NRT, Profle을 사용하여 레진 블록으로 제작된 만곡 근관에서의 apical transportation 양상 및 working length 변화를 서로 비교하는 것이다. 연구 재료 및 방법: 실험 방법은 30개의 레진 블록을 Schneider technque을 사용하여 만곡도 측정 후 각 group당 임의로 10개씩 배분하였다. 이를 각 Ni-Ti 파일을 사용하여 crown down technique으로 근관 성형하였다. 이의 분석을 위해 double radiograph superimposition method (Backman CA 1992)를 사용하고, 분석의 정확성과 일관성을 위해 특별히 고안된 jig, digital X-ray 및 apical transportation의 측정 시 CAD/CAM software를 이용하였다. Apical transportation 양은 '근단공-0.5 mm'부위로부터 0, 1, 3, 5 mm에서 측정 하였으며, working length 변화는 근관 성형 전후의 working length 변화를 측정하였다. 또 통계 처리는 각 group의 apical transportation 양과 working length 변화를 Kruskal-Wallis One Way Analysis로 분석 후 다중 비교는 Mann-Whitney U-test를 사용하였다. 결과: 각 group간 working lengh 변화 및 0, 1, 3 mm 부위에서의 apical transportation 측정 값 사이에는 유의할만한 차이가 관찰되지 않았으나(p = 0.924), 5 mm 부위에서는 K3와 Profile사이에 유의할 만한 차이가 있었다(p = 0.027). 결론: 서로 다른 기하학적인 형태를 가진 3가지 Ni-Ti 파일의 apical transportation 및 working length 변화 정도 평가시, 본 연구의 범위 내에서는 3가지 파일 모두 유의할 만한 차이를 보이지 않은 가운데 본래의 근관 형태를 잘 유지한다고 할 수 있다.

주사침 말단의 형상과 위치, 세척액 주입속도가 치근단에 작용하는 압력에 미치는 영향 (Effect of needle tip design and position, and irrigant flow rate on apical pressure)

  • 이창하;조설아;임범순;이인복
    • 대한치과재료학회지
    • /
    • 제45권4호
    • /
    • pp.275-286
    • /
    • 2018
  • 본 연구에서는 근관 내의 주사침 말단의 위치, 근관 세척액의 주입 속도, 주사침 말단의 형상이 근관 세척 시 발생하는 치근단 압력에 미치는 영향을 평가하고자 하였다. 5개의 사람 하악 소구치에 근관 와동 형성 후 #35(0.06 taper) 니켈-티타늄 회전식 기구로 근관을 형성하였다. 주사침 말단의 형상에 따라 구분되는 notched, side-vented, flat 3가지 종류의 주사침을 근단 협착부로부터 치관 방향으로 1, 3, 5 mm 거리가 되는 지점(주사침 말단의 위치)에 위치시켰다. 각 군에 대하여 세척액 주입 속도는 0.05, 0.1, 0.2, 0.3 ml/s로 변화시키면서 치근단 압력을 측정하였다. 나머지 조건이 동일한 경우 주사침 말단의 위치가 감소할수록, 세척액 주입 속도가 증가할수록 치근단 압력은 유의하게 증가하였다(p<0.05). 주사침 말단의 위치와 세척액 주입 속도가 동일한 조건 하에서 side-vented 주사침이 가장 낮은 치근단 압력을 보였고, notched, flat 주사침 순서로 치근단 압력이 유의하게 증가하였다(p<0.05). 주사침 말단의 위치가 1 mm인 군 또는 세척액 주입 속도가 0.1 ml/s 이상인 군에서는 나머지 조건에 관계없이 모든 경우에서 중심정맥압(5.88mmHg)보다 높은 치근단 압력을 나타냈다. Flat 주사침은 세척액 주입 속도와 주사침 말단의 위치에 따른 치근단 압력의 급격한 증가로 인해 임상에서 사용이 추천되지 않으며, 안전하고 효율적인 근관 세척을 수행하기 위해서는 근단 협착부로부터 치관 방향으로 3 mm 떨어진 지점에 주사침 말단을 위치시키고 0.05 ml/s 이하의 세척액 주입 속도로 근관 세척액을 적용해야 할 것이다.