• Title/Summary/Keyword: Room-temperature distribution

Search Result 422, Processing Time 0.022 seconds

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.

M ssbauer effect of ${Ni_{1-x}}{Cd_x}{FeAlO_4}$ (${Ni_{1-x}}{Cd_x}{FeAlO_4}$의 Mossbauer 효과)

  • Ko, Jeong-Dae;Hong, Sung-Rak
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.859-862
    • /
    • 2001
  • The crystal structure and magnetic properties of the $Ni_{1-x} Cd_xFeAlO_4$(0$\leq$x$\leq$0.5) have been investigated by means of X-ray diffractometry and Mossbauer spectroscopy. The samples($0\leq$x$\leq$0.5) have been prepared by the ceramic sintering method. The X-ray diffraction pattern shows that the crystal structure of the samples is a cubic spinel type. The lattice constant has been found by extrapolation using the Nelson- Riley function and it increases slightly from $8.321{\AA}$ to $8.410{\AA}$ with Cd concentration. The Mossbauer spectra for x<0.4 show a superposition of two sextets and a paramagnetic doublet at room temperature. The cation distribution for x=0 was determined to be $[Fe_{0.75}Al_{0.25}]^A[NiFe_{0.25}Al_{0.75}^BO_4$. The superparamagnetic doublet for x< 0.4 seems to be due to A1 ion in tetrahedral site by the superparamagnetic clustering effect.

  • PDF

A Study on The Performance of Ventilation and Thermal Environment for a Combined Type Diffuser in a Residential Space (거주공간에 대한 급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • In this study, the combined-type diffuser developed by the Authors, in a previous study, was applied to a residential space. The performance of a ventilation and thermal environment, created by the use of a combined-type diffuser was compared to the pan-type diffuser widely used in apartment houses. In cooling conditions, because of the relatively high air flow rate of ceiling cassette-type air conditioners, the characteristics of airflow distribution in a room were governed by the air conditioner's airflow. In heating conditions, because of the low air flow rate of the diffuser, the characteristics of airflow distribution were governed by the buoyancy effect created by cold external walls and a hot floor. In terms of the Air Diffusion Performance Index (ADPI), which is a thermal environmental index, the result of a combined-type diffuser was greater than a pan-type diffuser in both of cooling and heating conditions. Consequently, the combined-type diffuser showed equal or superior ventilation and thermal environment performance compared to a pan-type diffuser.

Comparision of Spray Angles of Pintle-Type Gasoline Injector with Different Measuring Methods (측정방법에 따른 핀틀형 가솔린 인젝터의 분무각 비교)

  • Kim, K.J.;Rhim, J.H.;No, S.Y.;Moon, B.S.;Kim, J.Y.;Kang, K.G.
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.9-16
    • /
    • 1999
  • Spray angle, a parameter which is most commonly used to evaluate. spray distribution, is important because it affects the axial and radial distribution of the fuel. Spray angles were measured and compared for the pintle-type gasoline fuel injector with n-heptane as a test fuel with the three different measuring techniques, i.e. digital image processing, shadowgraphy and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35MPa into the room temperature and atmospheric pressure environment. In digital image processing method, the transmittance level greatly influences the spray angle with the axial distance from the injector. From the experimental results by the shadowgraphy technique, it is obvious that the spray angle vary during the injection period. The results of spray angle from the spray patternator show that there exist the different spray angles in the different areas. The spray angles increase with the increase in the injection pressure for the three measurement techniques considered in this study. The spray angle is widely different, especially in the near region from the injector, according to the measurement techniques used in this experimental work.

  • PDF

Complexes of Manganese, Cobalt and Zinc with Dibasic Organic Acids in Aqueous, Ethanol-Water and Acetone-Water Solutions (망간, 코발트 및 아연과 2 염기 유기산 사이의 착물)

  • Sang Up Choi;Dong Jae Lee
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.31-39
    • /
    • 1974
  • Solutions of $Mn^{++}, Co^{++} and Zn^{++}$ were mixed with various dibasic organic acids in the presence of cation exchange resin at room temperature. The distribution ratios of the metal ions between resin and solution were measured, using radioactive metal ions as tracer. From the observed variation of the distribution ratios with acid anion concentrations, it was concluded that $Mn^{++}, Co^{++}$ and $Zn^{++}$ formed one-to-one complexes with succinate, malonate, o-phthalate and tartrate ions in aqueous, 20 % ethanol-water and 20 % acetone-water solutions. The results of the present investigation indicated that the relative stabilities of the complexes increased in the order: $Mn^{++} < Co^{++} < Zn^{++} complexes, Succinate < malonate < o-phthalate < tartrate complexes, Aqueous < mixed solvent systems.$

  • PDF

Changes of Microbiological Distribution in Food Waste for Animal Feed (동물 사료화를 위한 음식물 쓰레기의 미생물 분포 변화)

  • 김판경;박승춘;김명희;오태광;손천배
    • Journal of Veterinary Clinics
    • /
    • v.15 no.1
    • /
    • pp.156-161
    • /
    • 1998
  • This study investigated the microbiological changes and distribution of bacteria producing enzyme in order to change food wastes to animal feed during 6 days at room temperature. Food wastes were divided as follows: one is untreated food wastes containing 80% water content and another wastes containing 40% water content adiusted by wheat bran. During the fermentation of food wastes, Lactobacillus sp. and Streptococcus sp. were grown the top position among investigated microorganisms in both of food wastes. Numbers of total microorganisms were much more than untreated wastes during fermentation of flood wastes with 40% water content. But, Streptococcus sp. and Enterobacteriaceae from 4 to 6 days were not detected in treated wastes with 40% water contents. This fact indicated that the adiustment of water content in food waste was effective in fermentation. However, the numbers of microorganisms producing pretense were low in both treated and untreated food wastes. These results suggested that flood wastes should be treated as food wastes with 40% water content to maintain a lot of fermentative microorganisms such as Lactobacillus sp., Streptococcus sp. and yeasts together with pretense to make final animal feed.

  • PDF

The Theory of Smoke Movement by a Fire in an Enclosure (밀폐공간에서의 화재에 의한 연기의 유동 이론)

  • 노재성;유홍선
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.5-9
    • /
    • 1996
  • In foreign country such as U.S.A and Japan, considerable research has been done regarding the spread of smoke in room of fire involvement by using computer. But, in our country it has not been. So, this paper presents a detailed qualitative description of phenomena which occures during typical fire scenarios through numerical analysis. This research, in the view of field model, is focused on finding out the smoke movement and temperature distribution. And it is planned to analyze governing equation including smoke diffusion equation by numerical analysis with finite volume method and non-staggered grid system. The SIMPLE method for pressure-velocity couple and power-law scheme for convection terms are used. It shows that a plume is formed, hot plume is formed, hot plume gases impinge on the ceiling and they spread across it. then, it eventually reaches the bounding walls of the enclosure. It takes 60s for smoke to fill the enclosure.

  • PDF

FRETTING WEAR OF A SPRING SUPPORTED TUBE SUBJECTED TO TRANSVERSE VIBRATION

  • Kim, Hyung-Kyu;Yoon, Kyung-Ho;Lee, Young-Ho;Ha, Jae-Wook;Kim, Seock-Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.195-196
    • /
    • 2002
  • Studied is fretting wear behaviour of transversely vibrating tube which is supported by springs and dimples. This simulates the fuel rod fretting due to flow-induced vibration in a nuclear reactor. The contact between spacer grid springs and fuel cladding tubes arc brought into focus in this paper. From the mechanical viewpoint, a concave contact shape of spring is considered to perform a wider distribution of the contact stress. Sliding/impacting experiments are conducted in air at room temperature with the conditions of positive contact force and gap existence to accommodate the mechanical condition between the fuel rod and the grid spring during reactor operation. It is found that wear region is separated and wear volume becomes larger as the supporting condition becomes poorer. Spring and dimple cause similar wear.

  • PDF

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.