• 제목/요약/키워드: Room-temperature distribution

검색결과 421건 처리시간 0.027초

Depletion Kinetics of Ground State FeO Molecules by $O_2, N_2O, and \;N_2$

  • Son, H. S.
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권6호
    • /
    • pp.583-587
    • /
    • 2000
  • Depletion kinetics of ground state FeO molecules by $0_2$, $N_2O$ and $N_2$ has been studied at room temperature. The ground state FeO molecules were generated by photolysis of a $Fe$(CO)_5$/M(O_2$, $N_2O)/He$ mixture using an unfocused weak UV laser beam. The formation of ground state FeO molecules was identified by a laser-induced fluorescence (LIF) method. The intensity distribution of those undisturbed rotational lines suggests that the rotational temperature of the ground state FeO molecules is lower than room temperature. The LIF intensities of FeO molecules at different partial pressures of $0_2$, $N_2O$ and $N_2$ were monitored as a function of the time delay between the photolysis and probe laser pulses to obtain the depletion rate constants for the ground state FeO. They were 1.7+ 0.2x $10^{-12}$, 4.8 $\pm0.4$ x $10^{-12}$, and $1.4\pm$ 0.2x $10^{-12}cm^3$molecule^{-1}s^{-1}$$ by $0_2$, $N_20$, and $N_2$, respectively.

사파이어 기판의 방향에 따른 ZnO 박막의 결정화 거동 (Sapphire orientation dependence of the crystallization of ZnO thin films)

  • 조태식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1036-1038
    • /
    • 2001
  • The sapphire orientation dependence of the crystallization of ZnO thin films has been studied using real-time synchrotron x-ray scattering. The amorphous ZnO thin films with a 2400-${\AA}$-thick were grown on sapphire(110) and sapphire(001) substrates by radio frequency magnetron sputtering at room temperature. The amorphous ZnO films were crystallization into epitaxial ZnO(002) grains both on the sapphire(110) and on the sapphire(001) substrates. The epitaxial quality, such as mosaic distribution and crystal domain size, of the ZnO grains on the sapphire(110) is high, similar to that of the ZnO grains on the sapphire(001). With increasing the annealing temperature to 600$^{\circ}C$, the mosaic distribution and the crystal domain size of ZnO(002) grains in the film normal direction was improved and decreased, respectively.

  • PDF

A Study on the Warm Deep Drawability of Sheets in Cr-Coated Die

  • Seo, Dae-Gyo;Lee, Jae-Dong;Heo, Young-Moo;Chang, Sung-Ho;Park, Yi-Chun;Kim, Heon-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.839-846
    • /
    • 2001
  • Some deep drawing characteristics at elevated temperatures were investigated for the SCPI steel sheets by using a Cr-coated die. For this investigation, six different temperatures between room temperature and 250$\^{C}$, and six different drawing ratios ranging from 2.4 to 2.9 were considered. As a result, the limiting drawing ratio, the maximum drawing force and the maximum drawing depth were found to be affected sensitively by temperature, and more stable through-thickness strain distribution was observed at elevated temperatures. Some experimental results compared favorably with theoretical results obtained by using the finite element method.

  • PDF

크롬 코팅 처리된 금형에서 박판의 온간 딥드로잉 성형성에 관한 연구 (A Study on the Warm Deep Drawing Ability of Sheets on Cr-Coating Die)

  • 공경환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.63-70
    • /
    • 1999
  • Some deep drawing characteristics to the elevated temperatures were investigated for the SCP1 steel sheets by using the Cr-coated die. For this investigations six steps of temperature ranges from room temperature to 25$0^{\circ}C$ and six kinds of drawing ratio from 2.4 to 2.9 were adopted. As a result the limiting drawing ration maximum drawing force and the maximum drawing depth were sensitively affected by the elevated temperatures and the more stable thickness strain distribution was observed to the elevated temperatures, Some experimental results were compared with analytical results using the DYNA-3D code.

  • PDF

Characteristics of the Warm Deep Drawability of a Transformation-Induced Plasticity Steel Sheet

  • 서대교;장성호;공경환
    • 소성∙가공
    • /
    • 제8권3호
    • /
    • pp.221-221
    • /
    • 1999
  • Warm deep drawability in a square cup drawing was investigated using a newly developed high-strength steel sheet with retained austenite that was transformed into martensite during formation. For this investigation, six different temperatures between room temperature and 250℃, and five different drawing ratios ranging from 2.2 to 2.6 were considered. The results showed that the maximum drawing force and the drawing depth were affected by the change in temperature, and a more stable thickness strain distribution was observed at elevated temperatures. However, blue shortness occurred at over 200℃. FEM analysis using the LS-DYNA code was used to compare the experimental results with the numerical results for the thickness strain distribution.

크롬코팅 처리된 금형에서 박판의 온간 딥드로잉 성형성에 관한 연구 (A Study on the Warm Deep Drawing Ability of Sheets on Cr-Coating Die)

  • 서대교;이재동;최치수;최이천;김헌영
    • 소성∙가공
    • /
    • 제9권2호
    • /
    • pp.186-192
    • /
    • 2000
  • Some deep drawing characteristics to the elevated temperatures were investigated for the SCPI steel sheets by using the Cr-coated die. For this investigations, six steps of temperature ranges, from room temperature to 25$0^{\circ}C$, and six kinds of drawing ratio, from 2.4 to 2.9 were adopted. As a result, the limiting drawing ratio, maximum drawing force, and the maximum drawing depth were sensitively affected by the elevated temperatures, and the more stable thickness strain distribution was observed to the elevated temperatures. Some experimental results were compared with analytical results using the DYNA-3D code.

  • PDF

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

전자유압식 분사계에 의한 초고압 디젤분무의 입경분포에 관한 연구 (A Study on the Droplet Size Distribution of Ultra High Pressure Diesel Spray on Electronic Hydraulic Fuel Injection System)

  • 장세호;안수길
    • 동력기계공학회지
    • /
    • 제2권1호
    • /
    • pp.25-30
    • /
    • 1998
  • In order to investigate the droplet size distribution and Sauter Mean Diameter in a ultra high pressure diesel spray, fuel was injected with ultra high pressure into the environments of high pressure and room temperature by an Electronic Hydraulic Fuel Injection System. Droplet size was measured with the immersion liquid sampling technique. The immersion liquid was used a mixture of water-methycellulose solution and ethanol. The Sauter Mean Diameter decreased with increasing injection pressure, with a decrease environmental pressure (back pressure) and nozzle diameter. Increasing the injection pressure makes the fuel density distribution of the spray more homogeneous. An empirical correlation was developed among injection pressure, air density, nozzle diameter and the Sauter Mean Diameter of spray droplets.

  • PDF

바닥공조 시스템이 적용된 사무공간의 거주후 성능평가 (Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System)

  • 윤성훈;장향인;정해권;최선규;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구 (Experiments on the Effective Engine Room Ventilation in a Power Car)

  • 한석윤;이진호
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF