• 제목/요약/키워드: Room temperature distribution

검색결과 421건 처리시간 0.03초

Comparison and evaluation of 89Zr-labeled trastuzumab and Thio-trastuzumab : a potential immuno-PET probe for HER2-positive carcinomas

  • Un Chol Shin;Seoku Bae;Suk-man Kim;Min-Woo Lee;Han Sang Jin;Hyun Park;Kyo Chul Lee;Jung Young Kim;Ji Woong Lee
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.105-111
    • /
    • 2021
  • 89Zr is a positron-emitting radioisotope, which has known as well-suited radioisotope for use in a monoclonal antibody-based imaging agent for immuno-PET. The purpose of this study was to quantitatively evaluate the diagnostic ability of general trastuzumab and thio-trastuzumab as HER2 positive receptors based on Df hexadentate iron chelator. Desferrioxamine-p-SCN (Df-Bz-NCS) and desferroixamine-maleimide (Df-Mal) were purchased from Macrocyclics (Dallas, TX, USA). The trastuzumab was purchased from Roche (Schweiz), and thio-trastuzumab was obtained from professor Hyo-Jeong Hong group (Kangwon National University). The radioisotope 89Zr was produced by domestic purification system and KIRAMS using medical cyclotron (50 MeV, Scantronix). The conjugates of Df-trastuzumab and Df-thio-trastuzumab were prepared with Df-Bz-NCS and Df-Mal under basic aqueous solution (pH 8-9) at room temperature, respectively. The conjugates purified by PD-10 column were mixed with dried 89Zr chloride. 89Zr-labeled conjugates were purified and concentrated by Amicon ultra centrifugal filter. The preparation step and time of 89Zr-labeled conjugates was shorted as 4 steps within 2 hours. 89Zr-labeled conjugates showed the highly radiochemical purity of over 98%, and were very stable until 7 days by the analysis of radio-ITLC method. Each radio-labeled conjugates were also exhibited the highly stability in both PBS buffer and mouse serum. Immuno-PET imaging of 89Zr-labeled conjugates in mice bearing gastric cancer xenograft tumors with HER2 expression showed high tumor uptake in the NCI-N87 HER2-expressing. However, 89Zr-Df-Mal-thio-trastuzumab showed a relatively lower tumor-to-background ratio than 89Zr-Df-Bz-trastuzumab, as well as whole-body distribution. In the results, 89Zr-Df-Bz-trastuzumab was evaluated to have a relatively higher HER2 diagnostic ability than 89Zr-Df-Mal-thio-trastuzumab.

Tb2Bi1GaxFe5-xO12(x=0, 1)의 뫼스바우어 분광연구 (Mössbauer Study of Tb2Bi1GaxFe5-xO12(x=0, 1))

  • 박일진;김철성
    • 한국자기학회지
    • /
    • 제18권2호
    • /
    • pp.67-70
    • /
    • 2008
  • $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$(x=0, 1)의 조성을 가지는 분말 시료를 sol-gel 법과 진공봉합 열처리를 이용하여 합성하였다. x선 회절기, $M\ddot{o}ssbauer$ 분광기를 이용하여 시료의 결정구조 및 Ga 이온의 점유도에 관하여 연구하였다. XRD측정결과 $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$ (x=0, 1)의 결정구조는 Ia3d의 공간그룹을 갖는 cubic 구조이며, $Tb_2Bi_1Fe_5O_{12}$$Tb_2Bi_1Ga_1Fe_4O_{12}$의 격자상수 $a_0$는 각각 $12.497\AA$, $12.465\AA$으로 분석되었다. Rietveld 분석법을 이용하여 각 이온들이 점유하는 각각의 부격자 위치를 연구하였다. $Tb_2Bi_1Ga_1Fe_4O_{12}$ 시료의 분석결과, Tb, Bi 이온은 24c 자리에, Fe 이온은 24d, 16a 자리를 점유하였으며, 비자성 이온인 Ga 이온은 모두 16a 자리를 점유하는 것으로 분석되었다. $Tb_2Bi_1Ga_xFe_{5-x}O_{12}$(x=0, 1)의 미시적인 자기구조를 분석하기 위해 시료들의 $M\ddot{o}ssbauer$스펙트럼을 측정하였다. 상온에서의 $M\ddot{o}ssbauer$스펙트럼 측정결과 철 이온들의 흡수 면적비는 $Tb_2Bi_1Fe_5O_{12}$의 경우 24d와 16a자리에서 각각 60.8%, 39.2%로, $Tb_2Bi_1Ga_1Fe_4O_{12}$의 경우 24d와 16a자리에서 각각 74.7%, 25.3%로 분석되었다. 철 이온들의 흡수 면적비 분석을 통해 비자성이온인 Ga은 모두 16a 자리를 점유하는 것을 알 수 있었다.

시판 와사비 페이스트 제품의 품질 특성 및 Allyl Isothiocyanate 함량 (Quality Characteristics and Allyl Isothiocyanate Contents of Commercial Wasabi Paste Products)

  • 이효경;김도희;김용석
    • 한국식품위생안전성학회지
    • /
    • 제31권6호
    • /
    • pp.426-431
    • /
    • 2016
  • 시판 와사비 페이스트 제품의 품질 특성을 비교하기 위하여 이화학적 및 미생물적 특성, 그리고 와사비의 주요 향미 성분으로서 항균 활성을 나타내는 allyl isothiocyanate 함량을 분석하였다. 와사비 제품의 pH는 $4.12{\pm}0.01{\sim}4.90{\pm}0.01$ 범위에 있었고, 총산 함량은 $0.22{\pm}0.01{\sim}0.77{\pm}0.02%$ 범위에 있었으며, 냉장유통 제품(CW1, CW2)이 상온유통 제품보다 대체로 높은 값을 나타내었다. 상온유통제품(RW1~4)의 염도는 $4.27{\pm}0.06{\sim}7.53{\pm}0.12%$로 냉장유통 제품에 비해 높았다. 가용성 고형분 함량은 상온유통 제품(RW1~4)에서 $33.00{\pm}1.00{\sim}44.67{\pm}2.08^{\circ}Brix$로 나타나 냉장유통 제품(CW1~2)의 $22.00{\pm}1.73{\sim}27.00{\pm}1.00^{\circ}Brix$보다 높게 나타났다. Sorbitol 함량은 상온유통 제품에서 $378.90{\pm}63.79{\sim}724.37{\pm}7.85mg%$로 냉장유통 제품에 비해 유의적으로 높은 함량을 나타내었다. 일반세균 수는 유통방법 또는 포장형태와 관계없이 $ND{\sim}3.65{\pm}0.23log\;CFU/g$ 범위에 있었으며, 효모와 곰팡이는 모든 시료에서 검출되지 않았다. 상온유통 제품(RW1~4)의 allyl isothiocyanate 함량은 $53.35{\pm}0.08{\sim}159.76{\pm}0.8mg%$ 범위로 냉장유통 제품(CW1 $48.19{\pm}0.15mg%$, CW2 $24.07{\pm}7.69mg%$)보다 높았다.

온도변화에 기인한 토양미생물 우점종의 변화에 관한 연구 (Dominant-species Variation of Soil Microbes by Temperate Change)

  • 박갑주;이병철;이재석;박찬선;조명환
    • 환경생물
    • /
    • 제29권1호
    • /
    • pp.52-60
    • /
    • 2011
  • 식물과 그 식물의 근권미생물과의 협력관계는 이미 오래전부터 관심을 받아왔고 지구 기후변화에 따라 식물과 그 근권미생물의 생태 및 지구환경에 대한 적응성은 막대한 지장을 받을 것으로 생각되어 왔다. 따라서 지구온난화에 따라 식물뿌리에 서식하는 근권미생물인 토양미 생물의 우점종이 어떻게 변화하는지에 대해 규명하고자 본 실험을 실시하였다. 우선 한국 식물생태계의 대표종인 소나무 (A), 잣나무 (B), 상수리나무 (C), 오리나무 (D) 를 선발하여 각각 실온인 $27^{\circ}C$$29^{\circ}C$(실온$+2^{\circ}C$), $31^{\circ}C$(실온$+4^{\circ}C$), $33^{\circ}C$(실온$+6^{\circ}C$)에서 1년 이상 성장시킨 후 이들의 뿌리토양을 무균적으로 채취하여 미생물 screening법과 colony counting을 통하여 각각의 군에서 우점종을 선별한 뒤 16S rRNA 분석에 의해 이들 각각의 우점종을 동정하였다. 그 결과 소나무 $27^{\circ}C$에서는 Bacillus cereus와 Enterobacter sp. CCBAU 15492, 소나무 $29^{\circ}C$에서는 Bacillus sp. 210_64와 Enterobacter sp. CCBAU 15492, 소나무 $31^{\circ}C$에서는 Bacillus sp. 210_64와 Enterobacter ludwigii, 소나무 $33^{\circ}C$에서는 Bacillus sp. 210_64와 Enterobacter sp. CCBAU 15492, Bacillus marisflavistrain DS6이 검출되었고, 잣나무 $27^{\circ}C$에서는 Bacillus cereus Q1, Pseudomonas sp. PR1-3, Arthrobacter woluwensisstrain CBU05/5295, 잣나무 $29^{\circ}C$에서는 Bacillus sp. G3, Pseudomonas sp. PR1-3, Bacillus sp. 210_24, 잣나무 $31^{\circ}C$에서는 Bacillus cereus Q1, Pseudomonas sp. PR1-3, 잣나무 $33^{\circ}C$에서는 Bacillus coagulans strain, Pseudomo-Dominant-species Change of Soil Microbes 59 nas sp. PR1-3, Chryseobacterium sp. COLI2, 상수리나무 $27^{\circ}C$에서는 Bacillus cereus strain B1, Pseudomonas putida strain W30, Arthrobacter woluwensis strain CBU05/5295, 상수리나무 $29^{\circ}C$에서는 Bacillus cereus strain CICC10185, Pseudomonas putida strain W30, 상수리나무 $31^{\circ}C$에서는 Bacillus cereus strain CG-T2, Pseudomonas sp. W15Feb9B, 상수리나무 $33^{\circ}C$에서는 Bacillus sp. CCBAU 51490, Arthrobacter woluwensis strain CBU05/5295, 오리나무 $27^{\circ}C$에서는 Bacillus sp. B18, Pseudomonas sp. PD 16, Enterobacter sp. CCBAU 15492, 오리나무 $29^{\circ}C$에서는 Rhodococcus erythropolis PR4, 오리나무 $31^{\circ}C$에서는 Enterobacter cloacae, Pseudomonas sp. PD 16, 오리나무 $33^{\circ}C$에서는 Bacillus subtilis strain SYH15, Pseudomonas sp. PD16을 우점종으로 동정하였다. 이 중 소나무는 $33^{\circ}C$에서 Bacillus marisflavi strain DS6가 $27{\sim}31^{\circ}C$에서는 발견되지 않다가 온도가 상승함에 따라 출현한 새로운 우점종으로 나타났고 잣나무에서는 $27^{\circ}C$에서 Bacillus cereus Q1, $29^{\circ}C$에서는 Bacillus sp. G3, $31^{\circ}C$에서는 Bacillus cereus Q1 등의 Bacillus속이 주요 우점종으로 나타났으나 온도가 가장 많이 상승한 $33^{\circ}C$에서는 Chryseobacterium sp. COLI2으로 우점종이 변한 것을 확인하였다. 본 실험은 차후 더 다양한 온도에서의 토양미생물 우점종 변화에 대한 연구가 진행되어야 할 것으로 사료되며 이들 연구결과들이 연계되어 지구온난화와 미생물의 관계, 그리고 새롭게 출현한 토양미생물과 식물간의 관계를 규명하는데 도움이 되는 데이터가 도출 될 것으로 기대된다.

비자성 이온 Ga, In이 치환된 유화물 스피넬의 뫼스바우어 분광학 연구 (The Effect of Non Magnetic ion Substitution for the FeCr2-xMxS4(M=Ga, In) by Mossbauer Spectroscopy)

  • 손배순;김삼진;김철성
    • 한국자기학회지
    • /
    • 제16권1호
    • /
    • pp.6-10
    • /
    • 2006
  • 단일상 $FeCr_{2-x}M_xS_4$ (M=Ga, In; x=0.1, 0.3)에 대하여 x-선 회절기(XRD), 진동 시료 자화율 측정기(VSM), 뫼스바우어 분광기를 이용하여 비자성 이온의 치환효과를 연구하였다. 결정구조는 Rietveld프로그램을 이용하여 공간그룹이 Fd3m[Fe, Ga, In(8a); Cr, Ga, In(160); S(32e) (u, u, u)]인 입방 스피넬 구조임을 확인하였다. 비자성 이온 Ga이 치환된 시료의 경우, Ga이 치환 될수록 격자상수가 10.007에서 $9.996\;{\AA}$,으로 감소하는 반면, In이 치환된 시료의 경우, In이 치환 될수록 격자상수가 10.029에서 $10.092\;{\AA}$로 증가함을 확인하였다 VSM측정 결과 Ga과 In이 치환 될수록 Neel온도는 각각 180에서 188K, 173에서 160K로 변화하였는데, 이것은 격자상수의 변화에 따른 사면체 자리(A자리)와 팔면체 자리(B 자리)의 초교환 상호작용 세기의 변화로 해석 할 수 있었다 $4.2K\~300K$의 온도범위에 걸쳐서 뫼스바우어 스펙트럼을 분석한 결과 Fe이온이 각각 A자리와 B자리에 점유함을 확인 할 수 있었다. 이것은 비자성 이온 Ga과 In 이 A자리의 Fe이온의 비대칭적인 전하 분포를 야기시키는 것으로 해석할 수 있었다. 또한 Cr-S의 결합거리를 비교해 본 결과, $FeCr_{2-x}Ga_xS_4$(x=0.3)와 RFeCr_{2-x}In_xS_4$ (x=0.3)가 각각 2.41, $2.43\;{\AA}$$FeCr_{2-x}Ga_xS_4$(x=0.3)의 결합거리가 작아 공유 결합력이 커짐에 따라 비대칭적인 전하 분포를 유도함으로 해석할 수 있다. 이는 큰 전기 사중극자를 유도하는 결과와 일치함을 알 수 있었다.

사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구 (An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation)

  • 정미화
    • 한국직업건강간호학회지
    • /
    • 제3권호
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • HPLC를 이용한 아족시스트로빈과 이미다클로프리드, 메타벤즈티아주론의 토양 잔류분석 숙련도시험 (Proficiency Testing for the HPLC Analysis of Azoxystrobin, Imidacloprid and Methabenzthiazuron Residues in Soil)

    • 김찬섭;손경애;길근환;임건재
      • 농약과학회지
      • /
      • 제19권3호
      • /
      • pp.218-229
      • /
      • 2015
    • 농약등록 잔류시험 연구기관의 측정 능력 향상 및 신뢰도 향상을 위해 잔류분석 숙련도 시험을 실시하였다. 시험은 2012년 11월에 토양시료를 사용하여 수행되었다. 토양은 채취 후 습토상태로 5년간 보관하여 농약의 잔류수준이 매우 낮을 것으로 기대되는 밭토양을 사용하였다. Azoxystrobin과 imidacloprid, methabenzthiazuron을 토양잔류시험의 실내시험 토양시료 조제방법과 동일하게 처리하여 분배 포장하였고, 그 중 일부를 임의로 선정하여 시료의 균질도와 상온에서의 안정성을 확인하였다. 시험참여기관마다 3종 농약이 두 수준으로 처리된 토양시료 2점을 제공하였는데 그 중 하나는 모든 기관에 동일한 농도로 처리된 평가용이었고, 기관별로 다른 농도의 시료는 확인용으로 사용하였다. 아울러 대상농약성분의 정량을 방해하는 성분의 확인과 회수율시험 등에 사용하고, 필요한 경우 matrix-matched 표준용액을 사용할 수 있도록 무처리 토양과 3종 농약의 표준용액(농도 10 mg/L)을 제공하였다. 대상기관중 48개 기관이 결과를 제출하였고 제출된 분석결과의 중앙값을 잔류농약에 대한 설정값으로 사용하였다. 합목적 (fitness-for purpose) 표준편차는 토양잔류시험의 변이계수 허용한계 20%를 적용하여 계산하였다. 개별성분에 대한 평가에는 Z-score를 적용하였고, 3종 농약에 대한 전체적인 평가는 Z-score의 절대값의 평균으로 하였다. Z-score의 절대값이 2 이하로 적합하다고 평가된 기관은 농약별로는 azoxystrobin 48개, imidacloprid와 methabenzthiazuron은 46개 기관이었고 전체적 평가결과는 48개 기관 모두가 적합하였다. 따라서 본 숙련도시험결과 잔류시험 연구기관 대부분의 잔류분석 수행능력은 적절한 것으로 판단되었다.

    가스크로마토그래피를 이용한 토양 중 프로사이미돈과 클로르피리포스, 메톨라클로르의 잔류분석 숙련도시험 (Proficiency Testing for the Gas-chromatographic Analysis of Procymidone, Chlorpyrifos and Metolachlor Residues in Soil)

    • 김찬섭;손경애;길근환;김진배;홍수명;권혜영
      • 농약과학회지
      • /
      • 제17권2호
      • /
      • pp.94-106
      • /
      • 2013
    • 농약등록 잔류시험 연구기관의 측정 능력 향상 및 신뢰도 향상을 위해 잔류분석 숙련도 시험을 실시하였다. 시험은 2011년 10월에 토양시료를 사용하여 수행되었다. 토양은 채취 후 습토상태로 5년간 보관하여 농약의 잔류수준이 매우 낮을 것으로 기대되는 밭토양을 사용하였다. Chlorpyrifos와 metolachlor, procymidone을 토양잔류시험의 실내시험 토양시료 조제방법과 유사하게 처리하여 분배 포장하였고, 그 중 일부를 임의로 선정하여 시료의 균질도와 상온에서의 안정성을 확인하였다. 시험참여기관마다 3종 농약이 두 수준으로 처리된 토양시료 2점을 배분하였는데 그 중 하나는 모든 기관에 동일한 농도로 처리된 평가용이었고, 기관별로 다른 농도의 시료는 확인용으로 사용하였다. 아울러 대상농약성분의 정량을 방해하는 성분의 확인과 회수율시험 등에 사용할 수 있도록 무처리 토양과 3종 농약의 표준용액(농도 10 mg/L)을 제공하였다. 대상기관 중 47개 기관이 결과를 제출하였고 제출된 분석결과의 중앙값을 잔류농약에 대한 설정값으로 사용하였다. 합목적(fitness-for purpose) 표준편차는 토양잔류시험의 변이계수 허용한계 20%를 적용하여 계산하였다. 개별성분에 대한 평가에는 Z-score를 적용하였고, 3종 농약에 대한 전체적인 평가는 Z-score의 절대값의 평균으로 하였다. Z-score의 절대값이 2 이하로 적합하다고 평가된 기관은 chlorpyrifos와 procymidone의 경우 44개, metolachlor는 40개 기관이었다. 따라서 본 숙련도시험결과 잔류시험 연구기관 대부분의 잔류분석 수행능력은 적절한 것으로 판단되었다.

    어견류의 Trypsin활성 저해물질의 분포와 가공중의 변화 3. 염건조기 가공저장중의 TI 및 단백질품질변화 (Distribution of Trypsin Indigestible Substrate(TI) in Seafoods and Its Changes during Processing 3. Changes in TI and Protein Quality of Salted and Dried Yellow Corvenia(Pseudosciaena manchurica) during Processing and Storage)

    • 이강호;권혜란;유홍수
      • 한국수산과학회지
      • /
      • 제17권2호
      • /
      • pp.109-116
      • /
      • 1984
    • 염장방법을 달리하여 만든 염건조기의 단백질 품질을 평가하기 위하여, 실온저장 중의 트립신 활성저해물의 함량과 시험관적 단백질 개산소화율(in vitro apparent protein digestibility)의 변화를 측정하였으며, 병행하여 유효성 라이신의 보유양과 비효소적 갈변도의 변화도 분석 비교하여 각 실험결과에 대한 상관성을 검토하였다. 트립신 활성저해물의 함량은 저장 중 점차 증가하였으며, 저장 57일후에는 가공 직후에 비하여 $1.5{\sim}2$배에까지 증가하였다. 가공방법별로 비교하였을 때 $25\%$ 염수에 간하여 건조한 것이 TI함량으로 0.21mg/g solid로써 가장 적었고, $10\%$ 고형식염으로 간한 것은 0.30mg/g solid로써 가장 많았다. 시험관적 단백질 소화율에 있어서는, $25\%$ 염수로써 간하여 건조한 것을 제외하면, 모든 시료가 30일까지는 TI함량의 증가와 더불어 유의적으로 저하하였다. 저장 57일 후의 시험관적 소화율은 $25\%$ 염수로 간하여 건조한 것에서는 불과 $4\%$의 감소를 나타내었다. 전 저장기간을 통하여 비효소적 갈변색소는 유효성 라이신양의 감소 및 시험관적 단백질소화율의 저하와 더불어 증가하였다. 염장방법을 달리한 염건조기 제품 중에서는 $25\%$ 염수로써 간하여 건조한 것이 가장 낮은 갈변화율과 유효성 라이신의 감소를 보였다. 따라서 라이신의 실효화와 비효소적 갈변색소의 증가는 염건조기의 단백질 품질에 가장 주요한 영향인자임을 알 수 있었다.

    • PDF

    총담관결찰후 집토끼 Paneth세포의 변화에 대한 면역전자현미경적 연구 (Immunoelectron Microscopic Study on the Paneth Cell of Rabbit after the Common Bile Duct Ligation)

    • 박경호;조휘동;양남길;안의태;고정식;김진국
      • Applied Microscopy
      • /
      • 제24권2호
      • /
      • pp.78-92
      • /
      • 1994
    • Lysozyme has been reported to be present in the secretory granules of the Paneth cell, and lysozyme immunoreactivity has been detected by immunogold method in Paneth cells of the intestine of human, mouse and rat. The present study was aimed at clarifying the intracellular distribution and changes of the lysozyme immunoreactivity in rabbit Paneth cell after common bile duct ligation of rabbit, using the electron microscope immunogold technique. Healthy adult rabbits weighing about 2kg body weight were divided into normal and bile duct ligated groups. Common bile duct ligation was performed aseptically under ether anesthesia. Experimental animals were sacrificed on the 1st, the 3rd, the 5th, the 7th and the 14th day after the operation. Mucosal specimens from the intestinal gland of ileum were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde, followed by 1% osmium tetroxide, embedded in araldite mixture, cut with LKB-V ultratome. Ultrathin sections were placed on parlodion coated nickel grids (200mesh). The section-bearing grids were floated upside down on the added substance in a moist chamber at room temperature except for the primary antibody step, which was at $4^{\circ}C$. Sections were etched with a saturated solution of sodium m-periodate for 60min. After etching, sections were pretreated with 0.02M tris buffered saline (TBS), pH 8.4, with 1% bovine serum albumin (BSA, Sigma) for 60min, then treated polyclonal rabbit anti-human lysozyme (Dakipatts) diluted 1 : 50 in TBS with 0.1% BSA for 20hr. Subsequently, grids were incubated 60min in biotinylated goat anti rabbit IgG (Amersham) diluted 1 : 100 in TBS with 0.1% BSA. After this, sections were incubated 60min on streptavidin gold G10 (Amersham) diluted 1 : 50 in TBS with 0.1% BSA. After each step, the grids were briefly rinsed with TBS with 0.1% BSA. After the strepavidin gold step, the sections were jet washed with distilled water. Counterstain of the sections performed by uranyl acetate and lead citrate, and observed with JEM 100 CX II electron microscope. Observed results were as follow; 1. Secretory granules of mouse Paneth cells have a lysozyme immunoreactivity and also eosinophil leucocyte of rabbit applied for the positive-control stain, are well labeld with gold particles. 2. Normal rabbit Paneth cells have a lysozyme immunoreactivity restricted on the secretory granules. 3. Amount lysosomes containing myelin figures in the Paneth cells were significantly increased from 5th day after the common bile duct ligation. 4. Immunoreactivity of Paneth cell secretory granules were more activated on the 3rd day after the common bile duct ligation as compared with those of the normal animal. But the lysozyme immunoreactivity were decreased from the 5th day after the common bile duct ligation. 5. Considering the above finding, lysozyme contained Paneth cell are affected following of common bile duct ligation, whereas lysosomes containing myelin-figure do not exhibit any immunoreactive relationship with those of secretory granules.

    • PDF