• Title/Summary/Keyword: Room fire test

검색결과 131건 처리시간 0.026초

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

안전기준을 만족하는 철도차량 내장재의 화재 열방출율 측정시험 (A Fire Test Measuring the Heat Release Rate of Railway Car Interior Materials Satisfying the Korean Safety Guideline)

  • 박원희;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.40-49
    • /
    • 2009
  • 철도차량 내장재를 설치한 화재 시험 공간(ISO 9705)에서 대규모 화재시험이 수행되었다. 여기서 사용된 내장재는 2004년 12월에 공포된 철도차량에 대한 안전기준을 만족하는 내장재이다. 화원으로는 가스버너를 이용하였으며 가스버너의 출력은 시간에 따라 증가하도록 설정하였다. 본 시험의 목적은 철도차량 내장재의 화염전파와 발화에 대한 화재 성능 평가이며, 플레시오버로 성장하는 철도차량 내장재를 포함하는 화재에 대한 여러 데이터들의 확보이다. 이 데이터들은 철도차량 내장재의 화재 성장을 예측하는 모델을 검증하고 개발하는데 사용될 것이다.

실대화재시험의 화재성능 등급분류에 관한 연구 (Study on the combustion performance's classification system for large scale fire tests)

  • 박계원;임홍순;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.99-104
    • /
    • 2008
  • The combustion properties of sandwich panels were tested and analyzed according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) test method for the purpose of establishing the classification of reaction to fire performance. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, and so on, were analyzed for specific four materials about sandwich panel systems on each 5 times, totally 20 times. Finally, elements for Classification system were suggested and evaluations for those elements were made.

  • PDF

스프링클러 반응시간 예측에 대한 화재모델의 비교 (A Comparison of the Prediction of Sprinkler Response Time Applying Fire Models)

  • 김종훈;김운형;이수경
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.46-52
    • /
    • 2001
  • To evaluate the usability of compartment fire models for predicting sprinkler response time, fire experiment was conducted and measured sprinkler response time. The experimental data was compared with zone model "FASTLite"and field model "FDS"and field Model "SMARTFIRE" A Compartment fire conducted in a 2.4 m by 3.6 m by 2.4 m ISO 9705 room and measured H.R.R was approximately 100.3 kW. In test, Sprinkler activation temperature used is $72^{\circ}c$ and responded at 198s. The output of FASTLite, SMARTFIRE and, FDS for this fire scenario were 209s, 183s, and 192s, respectively. As a results, prediction using FDS model approached to that of test very closely and other models showed good approximated results also.

  • PDF

룸코너 실험을 이용한 공동구 케이블 화재 시 수평·수직 방향 온도 분석에 관한 연구 (Study on Horizontal and Vertical Temperature Analysis of Cable Fire in Common Duct using Room Corner Experiment)

  • 김재엽;민세홍
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.634-643
    • /
    • 2023
  • 연구목적:지하공동구 화재는 꾸준히 발생하고 있으며, 화재로 인한 재산 및 인명피해 중 특히 재산피해의 비중이 더 크다. 공동구에서 발생하는 케이블 화재는 수직으로 빠르게 확산되어 큰 위험을 초래할 수 있으며 본 논문은 실험을 통해 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 연구방법:지하공동구 케이블 화재의 특성을 분석하기 위해 룸코너 실험을 통해 열방출율 및 온도변화를 측정하여 케이블 화재의 수직 및 수평 방향 전파에 대하여 정량적으로 비교·분석하였다. 연구결과:룸코너 실험(ISO 9705)을 통해 각 데이터 로거 Point 온도변화를 비교하여, 화재 진행 시 1단 케이블 중앙 Point 기준 수평방향과 수직방향으로의 착화온도 도달시간이 각각 589초, 536초로 수직방향 화재 전파가 53초 빠르다는 것을 확인할 수 있었다. 화재의 수직전파가 수평전파보다 상대적으로 빠르게 진행된다는 것을 증명하였고, 각 층 케이블 트레이별 화재 수평 전파 속도를 비교하여, 3단 케이블은 2단 케이블의 3.4배, 2단 케이블은 1단 케이블의 1.5배 빠른 속도로 진행되어 상방향에 위치한 케이블일수록 화재 확산 속도가 상대적으로 빠르며 화재 크기는 커진다는 것을 알 수 있었다. 결론:본 연구에서는 케이블 화재의 위험성을 파악하고 룸코너 실험의 결과를 바탕으로 케이블 화재 시 화재 수직전파의 위험성에 대해 분석하였다. 화재 확산을 막기 위한 연구와 화재 수직방향 전파를 예방하기 위한 소방 대응정책 등이 필요하며, 본 연구 논문의 시험 결과로 공동구 및 기타 화재 위험성 평가에 활용되기를 기대한다.

소규모 주거 공간 실물화재실험을 통한 적재 가연물의 연소특성 분석 (An Analysis of Combustion Characteristics of Residential Facilities through Real Fire Tests in a Small Residential Space)

  • 양소연;문민호;원정훈
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.73-79
    • /
    • 2022
  • In this study, real fire tests were performed on representative combustibles of residential facilities to analyze the fire behavior and combustion characteristics in a small residential space. The considered combustibles were a sofa, a combination of a desk and a chair, and a combination of a mattress and an electric mat. A compartment space fire test was performed using the room corner test equipment prescribed in the KS F ISO 9705 specification. Three real fire tests were conducted by placing the combustible material inside a small compartment with insulation and finishing materials and by igniting the combustible material. Results showed that the peak heat release rate and peak smoke production rate occurred in the combination of the mattress and electric mat. Furthermore, from the result of the fire rate analysis, it was estimated that the fire risk of the mattress and electric mat combination was the highest, followed by the sofa and thedesk and chair combination.

Bond behavior of PP fiber-reinforced cinder concrete after fire exposure

  • Cai, Bin;Wu, Ansheng;Fu, Feng
    • Computers and Concrete
    • /
    • 제26권2호
    • /
    • pp.115-125
    • /
    • 2020
  • To reduce the damage of concrete in fire, a new type of lightweight cinder aggregate concrete was developed due to the excellent fire resistance of cinder. To further enhance its fire resistance, Polypropylene (PP) Fibers which can enhance the fire resistance of concrete were also used in this type of concrete. However, the bond behavior of this new type of concrete after fire exposure is still unknown. To investigate its bond behavior, 185 specimens were heated up to 22, 200, 400, 600 or 800℃ for 2 h duration respectively, which is followed by subsequent compressive and tensile tests at room temperature. The concrete-rebar bond strength of C30 PP fiber-reinforced cinder concrete was subsequently investigated through pull-out tests after fire exposure. The microstructures of the PP fiber-reinforced cinder concrete and the status of the PP fibre at different temperature were inspected using an advanced scanning electron microscopy, aiming to understand the mechanism of the bonding deterioration under high temperature. The effects of rebar diameter and bond length on the bond strength of PP fiber-reinforced cinder concrete were investigated based on the test results. The bond-slip relation of PP fiber-reinforced cinder concrete after exposure at different temperature was derived based on the test results.

공동주택 내부 공간의 잔향시간 특성 조사 연구 (A Study on the Reverberation Time Characteristics of Inside Space of Apartment Buildings)

  • 정정호;이병권;전진용
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.291-298
    • /
    • 2015
  • In this study, the reverberation time of apartment living room was measured and distribution of the reverberation time was analyzed. In addition, sound field characteristics of mock-up test room similar with living room and timber structured bedroom was investigated with addition of furniture and sound absorption material. Average reverberation time of unfurnished apartment unit was 1.11 s, and reverberation time in 630 Hz~2000 Hz bands were longer than 1.2 s. It was found that from the field measurement results, reverberation time characteristic of furnished apartment living room was uniform in most of frequency bands. Averaged reverberation time of furnished living room was 0.48 s and the reverberation time of bedroom was 0.44 s. Standardized sound pressure level correction values were calculated from the average reverberation time of furnished and unfurnished apartment units. The correction value of unfurnished living room was −3.4 dB and that of furnished living room was 0.2 dB. Measured reverberation time of furnished and unfurnished apartment units indicated that reference reverberation time; 0.5 s, in KS and ISO standards is reasonable also in Korean residential environment.

수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms)

  • 정정호;이병권;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구 (A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire)

  • 진승현;김혜원;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF