• 제목/요약/키워드: Room Unit

검색결과 703건 처리시간 0.023초

소아환자에서 대복재정맥을 통한 하대정맥도관법의 유용성 (Usefulness of Tunneled Trans-saphenous IVC Catheters for Long Term Venous Access in Pediatric Patients)

  • 김승환;김성민;오정탁;한석주;최승훈
    • Advances in pediatric surgery
    • /
    • 제12권2호
    • /
    • pp.167-174
    • /
    • 2006
  • Central venous catheter (CVC) for long-term venous access is indispensable for various reasons including hyperalimentation, frequent blood sampling, frequent IV drug use in pediatric patients. We report clinical experience of surgical neonates in whom CVC was inserted primarily via great saphenous vein into suprarenal inferior vena cava. From March 2004 to March 2006, we performed CVC insertion via saphenous vein - contralateral side to main wound - into suprarenal inferior vena cava in surgeries of neonates. 2.7Fr or 4.2Fr, single lumen, tunneled Broviac catheters (Bard Access system, Inc, Salt Lake City, Utah) were used. Skin exit site of tunneled catheter was located in ipsilateral flank area just below edge lower rib. At the end of the procedure, location of the catheter tip was confirmed by plain radiography of abdomen. We retrospectively reviewed the admission records of the patients including nursing staff charts. Nine (50.0 %) patients were male and nine (50.0%) were female. Median gestational age was 38 weeks (range, 29-42 weeks) and median birth weight was 3,105 gm (range, 1,040-3,720 gm). Median age at catheter insertion was 38.5 days (range, 1-236 days). The purpose of CVC insertion was short-and long-term hyperalimentation in nine (50.0 %) patients. CVC insertion was performed in operation room under general anesthesia in sixteen (88.9 %) patients (in these cases, CVC insertion was performed just prior to concurrent operation) and neonatal intensive care unit (NICU) under local anesthesia with adequate sedation in two (11.2%). During the admission period (total catheter-indwelling time: 553 days), CVC functioned well without any significant side effects. Transient swelling of the ipsilateral leg (n=1, 5.6 %) and transient migration of catheter tip (n=1, 5.6 %) were noted, which did not affect function of the indwelled CVC. Mean catheter-indwelling time was 30.7days (range, 3-72 days). All catheters were removed electively except two mortality case. Complications, such as thrombosis, infection, kinking or extravasation of drugs, were not observed in our study period. Tunneled trans-great saphenous vein inferior vena cava catheters are not only comparable to cervical CVCs in terms of function and complication rates, but also very beneficial in selected patients, especially those in whom cervical approach is technically impossible or contraindicated.

  • PDF

노인그룹홈의 운영과 생활환경에 관한 연구 -전주시와 광주시를 중심으로- (A Study on the Management and Living Environment of the Group-homes for the Elderly -Focusing on Jeonju and Kwangju-)

  • 안경온
    • 한국생활과학회지
    • /
    • 제18권4호
    • /
    • pp.841-855
    • /
    • 2009
  • The main objective of this study is to examine the situations of group-homes for the elderly and clarify the problems of them. This study investigates the present conditions of welfare facilities and supply conditions. 4 group-homes were surveyed in Jeonju and Kwangju cities. Data was collected through various ways including the survey conducted by facility operators, the measurement of living space, and photo-takings. The major results of this study are as follows: 1) With the introduction of nursing care insurance in 2008, the increase of the demand and supply to group-home will be expected, due to less cost for recuperation. The care of elderly in homelike atmosphere is effective to the elderly suffering from dementia. Therefore, it is proper that the supply of group-homes for dementia will be needed. 2) Group-homes for the elderly are being supplied under the standards of welfare facilities in the present. Separate supply standards, however, are needed because they are not suitable for small scale group-homes. 3) To supply Group-homes for the elderly on a one-unit basis would cause various problems such as economical unreality, personnel distribution and so on. It is necessary to supply more than two units for more efficient management. 4) The management of group-homes for the elderly is financially unstable because the operating funds heavily depend on the users or people who are connected with the facilities through private networks. Therefore, additional support is needed to settle the financial problem. It would be helpful to build the public networking that provides information about the group-home for the elderly for the public. 5) In case of the increase in the supply of the group-home in a residential area, it could be helpful to promote the group-home to the public. 6) The operators state that the main problems of group homes for the elderly lie in financial difficulties and the shortage of professionals and volunteers. The financial, personnel, and material support for personnel and the supervision of management are required for the transparency and effectiveness of the facility management. In addition, the closer network and cooperation system with the community is required. 7) The present living environments for group-homes for the elderly leave much room for improvement, considering the physical condition of the elderly. The more careful selections in the color, shape, material, and equipment of the facilities should be made for the convenience of the elderly users.

산소 호흡을 이용한 뇌의 관류 자기공명영상 (Perfusion RRI of the Brain Using Oxygen Inhalation)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.113-119
    • /
    • 2000
  • 목적 : 산소호흡을 이용한 뇌의 관류 자기공명영상의 임상적용 가능성을 알고자 하였다. 대상 및 방법 정상 성인 지원자 2명과 3명의 환자, 각각 모야모야병 환자 1명, 뇌경색환자 1명, 뇌수막종 환자 1명을 대상으로 하였으며, 1.5 Tesla의 자기공명영상 장치를 이용하여 뇌의 자화율 대조 (susceptibility contrast) echo planar image (EPI) 방법으로 뇌영역을 10 slice씩 25회(검사시간은 검사당 1.6초) 영상을 얻었다. 검사자는 안면마스크를 착용한 상태로 스캔 시작 8초 후부터 35초가지 산소 15 liter/min를 실내 공기와 혼합되어 흡입되도록 하였다. 획득된 영상을 Magnetom Vision (Siemens Medical Systems, Erlangen, Germany)의 VB31C 프로그램을 이용하여 산소투여전(3골 번째 검사)과, 산소투여 후의 초기 (12-18 번째 검사)와 후기(19-25 번째 검사) 군으로 나누었다. 초기 및 후기 군과 산소투여전 군의 신호차이는 Z-score 0.7 내지 1.0으로 하여 여러번 영상후 처리를 반복하여 difference map을 얻어서, T1 강조영상에 중첩시켜 관류 영상을 얻었다. 모야모야병 환자는 추가로 Gd-DTPA를 0.1 mmol/kg급속주사 후 동일한 방법으로 관류 영상을 얻어 산소호흡에 의한 관류 영상과 비교하였다. 결과 : 산소 공급 후에 시행한 자화율 대조 EPI 방법으로 2명의 지원자와 각각 1예의 모야모야병, 뇌경색, 뇌수막종 증례에서 혈류 분포를 반영하는 관류 영상을 얻을 수 있었다. 모야모야병 1예의 산소 호흡에 의한 관류 영상은 Gd-DTPA투여후의 관류 영상과 유사한 양상을 보였다. 결론 : 산소호흡을 이용한 자화율 대조 EPI 방법은 향후 뇌의 관류 자기공명영상 방법으로 적용이 가능하리라고 생각된다.

  • PDF

스마트폰 어플리케이션을 활용한 전문심폐소생술 시뮬레이션 재학습이 간호사의 지식 및 교육 만족도에 미치는 효과 (The Effects of an Advanced Cardiac Life Support Training via Smartphone's Simulation Application on Nurses' Knowledge and Learning Satisfaction)

  • 표미연;김정연;손주온;이은숙;김향숙;김계옥;박혜정;김민주;안기현;양정란;유준희;김영아;김효진;최모나
    • 임상간호연구
    • /
    • 제18권2호
    • /
    • pp.228-238
    • /
    • 2012
  • Purpose: The purpose of this study was to examine how an Advanced Cardiac Life Support (ACLS) simulation application via smartphone effects nurses' ACLS knowledge and learning satisfaction. Methods: The participants were selected from nurses in medical Intensive Care Unit (ICU), surgical ICU and emergency room. The experimental group consists of fifty nurses who were self-learned with ACLS simulation application via smartphone and the control group of seventy-one nurses who used traditional learning materials. Outcome variables included nurses' knowledge and learning satisfaction which were collected before and after the intervention. Results: The scores of ACLS knowledge were higher in the control group compared to the experimental group (p=.001) while learning satisfaction showed no statistical difference (p=.444). In learning satisfaction, the experimental group showed higher interest than the control group (p=.019) while the control group rated higher on the item, 'the contents of education was reliable' (p=.007). Conclusion: ACLS knowledge score was graded higher in control group that used traditional learning method than the experimental group that used the smartphone application. This study showed that training with the new material significantly increased nurses' interest in ACLS education. Hence, more applications for smartphones should be developed to provide self-learning environment for nurses and improve care quality.

항암 화학요법 환자의 피로 관련 요인 (Factors Related to Fatigue in Cancer Patients Receiving Chemotherapy)

  • 정은자;정영;박미영
    • Journal of Hospice and Palliative Care
    • /
    • 제7권2호
    • /
    • pp.179-188
    • /
    • 2004
  • 목적: 본 연구는 항암 화학요법을 받는 암 환자가 경험하게 되는 피로 정도와 관련 요인을 파악하여 화학 요법을 받는 암 환자의 피로 완화를 위한 간호 중재를 위한 기초 자료를 제공하기 위해 시도되었다. 방법: 2002년 8월 8일부터 10월 2일까지 광주 지역의 한 대학 부속 병원 외래 주사실과 병동에 입원하여 화학 요법을 받는 만 20세 이상의 90명의 환자를 대상으로 하였다. 수집된 자료는 SPSS v10.0 통계 프로그램을 이용하여 분석하였고, 빈도 및 t-검정, 분산분석, 피어슨의 상관관계 분석, 다중회귀 분석하였다. 결과: 1. 대상자의 전체 평균 피로 점수는 5.24점이었고 환자 형태별로 볼 때 외래 환자에서의 평균 피로점수가 평균 4.75점, 입원 환자의 평균 피로 점수는 6.22점으로 유의한 차이를 보였으며, 피로는 신체적 증상 점수와 비교적 높은 정도의 정적 상관관계를 갖는 것으로 나타났고, 오심, 구토, 식욕저하, 동통, 외모변화, 기동성장애의 6개 항목에서 피로와 유의한 상관관계를 보였다. 2. 대상자의 피로는 수면 양상 중 낮잠 여부와 유의한 차이를 보였고 낮잠을 자는 군에서 자지 않는 군보다 피로를 적게 경험하는 것으로 나타났으며, 기분 점수와 유의한 정적상관관계를 갖는 것으로 나타났으며, 불안, 혼돈, 우울, 기운, 분노 항목에서 모두 유의한 상관관계를 보였다. 3. 대상자의 피로는 전이여부, 화학요법 주기, 과거 수술 여부, 과거 방사선 치료 여부에서 유의한 차이를 보였으며, 피로정도는 헤마토크릿치의 감소, 체중감소군에서 유의한 부적 상관관계를 보였고, 영적 안녕은 피로와 유의한 상관관계를 보이지 않았다. 단계적 다중 회귀분석 결과 기동성 장애, 식욕저하, 분노 변수가 전체 피로의 51.6%를 설명하였다. 결론: 암환자의 피로완화를 위한 간호중재로써 신체적 증상에 대한 간호중재가 비중있게 적용되어야 할 것이며, 심리적 고통을 경험하는 암환자에 대한 간호중재를 계획함에 있어서도 영적 안녕상태 증진을 위한 방안모색이 필요하리라 본다.

  • PDF

액체전해액의 함량에 따른 리튬이온전지 코인셀의 전기화학적 특성 연구 (Effect of Electrolyte Amounts on Electrochemical Properties of Coin-Type Lithium-Ion Cells)

  • 윤별희;한태영;김석우;진다희;이용민;유명현
    • 전기화학회지
    • /
    • 제21권2호
    • /
    • pp.39-46
    • /
    • 2018
  • 많은 실험실 기반의 리튬이차전지 실험결과는 코인셀로부터 얻어진다. 이는 조립의 용이성, 저렴한 가격, 실험 결과의 우수한 재연성 등에 기인한다. 코인셀은 케이스(case), 가스켓(gasket), 스페이서(spacer disk), 스프링(wave spring)로 구성되어 있으며, 이러한 구조적인 특성으로 인하여 코인셀은 상용화된 파우치, 각형 및 원통형 전지에 비하여 전극 무게 대비 많은 양의 전해질을 포함하게 된다. 하지만 과량의 전해액이 셀의 성능에 미치는 영향에 대한 연구는 현재까지 이루어지지 않은 상황이다. 본 연구에서는 액체 전해액의 양을 다르게 제어하여 코인셀에 미치는 영향을 알아보고자 하였다. 전해액의 양은 전극 용량 대비 30, $100mg\;mAh^{-1}$(전해액의 양/전극용량)로 제어하였으며, 조립된 셀의 전해액 함량에 따른 전기화학적 특성을 확인하기 위해 초기 충 방전 곡선과 상온 ($25^{\circ}C$), 고온 ($60^{\circ}C$) 및 고전압(4.5 V)에서의 수명특성평가를 진행하였다. $30mg\;mAh^{-1}$의 전해액을 포함하는 단위 전지의 경우, 고온 및 고전압 조건에서 $100mg\;mAh^{-1}$의 경우에 비해 매우 우수한 방전 용량 유지 특성을 나타내었다. 전자는 후자보다 더 큰 내부저항 증가를 보였으며, 이를 통해 전해액의 양이 전지의 방전 용량 유지 특성에 매우 큰 영향을 미치고 있음을 확인하였다.

저장중 벼, 현미 및 백미에서의 마디발동물 군집의 환이 (Ecological Successions of Arthropod Communities in Stored Rough Rice, Polished Rice and Brown Rice)

  • 류문일;조혜원;김영배
    • 한국응용곤충학회지
    • /
    • 제29권1호
    • /
    • pp.31-42
    • /
    • 1990
  • 벼, 현미 및 백미를 실내에 저장하면서 저곡생태계의 구성, 군집의 천이 및 이에 따르는 군집의 에너지 변환 양상을 1987년 2월부터 1988년 11월까지 조사하였다. 곡물의 온도 변화는 약 4주간의 시차를 두고 저장실의 온도 변화에 따랐다. 벼, 현미, 백미의 함수량은 실내 상대습도가 39-90% 의 범위에서 변화하였음에도 각각 12.7 $\pm$ 0.4, 13.1 $\pm$ 0.4, 및 13.5 $\pm$ 0.3%로 안정된 수준에 있었다. 마다발동물의 군집천이는 벼, 현미, 백미에서 각각 다르게 나타났다. 벼의 경우 우점종이 가루민다드미벌레에서 어물다드미벌레로 천이하였다. 현미 및 백미의 정우에는 밀가루줄명나방에서 쌀바구미, 미동정 기생충, Anisopteromalus calandrae Howard와 거짓쌀도둑의 우점으로, 다시 쌀바구미로 천이하였다. 그러나 백미에서는 호미와는 달리 다드미벌레목 2종의 일시적인 우점 현상이 관찰되었다. 대체적으로 벼에서의 군집은 현미냐 백미에서의 군집에 비해 단순하게 구성되었으며 불안정하였다. 천립중의 약화는 벼와 백미의 경우에는 관찰할 수 없었으나 현미의 경우 마디발동물의 활동이 활발했던 시기에 다소 감소하였다. 그러나 회분함량은 현미, 백미 및 벼에서 공히 증가한 자취를 불 수 없어 저장기간 중 곡물생태계의 에너지의 손실은 미미하였단 것으로 판단되었다.

  • PDF

Quantitative Light-Induced Fluorescence-Digital과 Cariview의 우식예측 연구에 대한 활용도 평가 (Applicability Evaluation of Quantitative Light-Induced Fluorescence-Digital and Cariview in Cries Prediction Study)

  • 이수영;임순연;배현숙
    • 치위생과학회지
    • /
    • 제13권4호
    • /
    • pp.403-409
    • /
    • 2013
  • 본 연구는 초기우식 진단장비인 QLF-D와 새로운 치아우식활성 검사법인 Cariview를 우식예측 연구에 활용할 수 있는지를 평가하기 위하여, 만 3세 아동 57명을 대상으로 구강검사를 실시한 후 우식경험도를 분석하고 이들 간의 상관성을 평가하여 다음과 같은 결과를 얻었다. 1. 연구대상자의 우식경험도 조사 결과, 우식경험유치지수는 평균 1.84였으며, QLF-D를 이용한 분석 결과는 치면 세균막 부착에 대한 점수가 1.47이었고, 연구대상자 당 평균 1개 정도의 초기우식병소($0.96{\pm}1.21$)가 있는 것으로 나타났다. 또한 Cariview 검사에서 산생성능은 평균 27.52로 나타났고, 연구대상자 중 68%가 저위험군에 속하는 것으로 파악되었다. 2. 우식경험유치지수와 초기우식병소 개수의 상관계수가 0.617, 치면세균막 부착정도(SPS)와는 상관계수가 0.500으로 비교적 강한 상관관계를 확인할 수 있었고(p<0.01), 우식경험유치지수와 Cariview 결과(0.286) 간에는 유의한 양의 상관관계가 나타났다(p<0.05). 그러나 우식유치지수, 우식경험충전유치지수에서는 Cariview 점수와의 상관관계를 확인할 수 없었다. 이상의 결과를 종합해보면, QLF-D를 이용하여 분석한 치면세균막 점수와 초기우식병소는 우식예측에 가장 중요한 영향을 주는 과거 우식경험에 높은 상관성을 보였으므로, 초기우식병소 탐지와 치면세균막 부착 정도를 동시에 파악할 수 있는 QLF-D는 우식예측 연구에 유용한 장비로 활용할 수 있을 것이다.

$\alpha-Fe_2O_3$ 박막에서 스핀 재 정렬에 관한 연구 (The Spin Reorientations in $\alpha-Fe_2O_3$ Thin Film)

  • 서정철;이호선
    • 한국자기학회지
    • /
    • 제11권1호
    • /
    • pp.21-25
    • /
    • 2001
  • Si 기판 위에 $\alpha$-Fe$_2$O$_3$ 박막을 pulsed laser deposition system으로 제조하여 결정학적 및 자기적 성질을 X선 회절 및 Mossbauer 분광법을 사용하여 연구하였다. 박막의 제조조건은 laser의 출력 5.128 W/$cm^2$, 산소의 압력 0.1 torr, 기판의 온도 30$0^{\circ}C$에서 가장 이상적이었으며 이를 공기 중 80$0^{\circ}C$에서 1일간 열처리하였다. 입자는 크기는 길이 200~300nm, 폭 70-150 nm정도의 타원체로 기판에 비스듬히 누운 형태를 취하고 있으며 결정은 육방정계 형태의 corundum 구조로서 결정상수는 a = 5.03 0.05 $\AA$, c = 13.73$\pm$0.05 $\AA$로 측정되었다. 원자의 스핀 방향은 감마선 방향(기판에 수직 방향)에 대하여 평균적으로 Morin 변환 이하에서는 38$^{\circ}$, 그 이상에서는 48$^{\circ}$의 각을 이루며 특정한 방향을 선호하고있는 것으로 나타났다. Morin 변환은 200 K에서 실온가지 넓은 온도 범위에서 일어나며, c-축에 대한 원자의 스핀 방향은 48$^{\circ}$에서 80$^{\circ}$정도의 변화만이 관측되었다.

  • PDF

용탕단조법에 의한 AC8A/$Al_2O_3$ 복합재료의 기계적 성질에 관한 연구 (A Study on the Mechanical Properties of AC8A/$Al_2O_3$ Composites.)

  • 김기배;김경민;조순형;윤의박
    • 한국주조공학회지
    • /
    • 제11권6호
    • /
    • pp.475-481
    • /
    • 1991
  • In this study the fabrication technology and mechanical properties of AC8A/$Al_2O_3$ Composites by squeeze casting process were investigated to develope for application as the piston materials that require good friction, wear resistance, and thermal stability. AC8A/$Al_2O_3$ composistes without a porosity and the break of preform were fabricated at the melt temperature of $740^{\circ}C$, the preform temperature of $500^{\circ}C$, and mold temperature of $400^{\circ}C$ under the applied pressure of $1200kg/cm^2$ as the results of the observation of microstructures. As the results of this study, the tensile strength of AC8A/$Al_2O_3$ composites was not increased linearly with $Al_2O_3$ volume fraction and so it seemed not to agree with the rule of mixture, which had been used often in metal matrix composite. Also the tensile strength after thermal fatigue test was little different from that before the test. Consequently it was thought that AC8A/$Al_2O_3$ composites fabricated under our experimental conditions had a good thermal stability and subsequently a good interface bonding. Wear rate(i.e., volume loss per unit sliding distance) of AC8A/$Al_2O_3$ composites was decreased with $Al_2O_3$ volume fraction and the sliding speed at both room temperature and $250^{\circ}C$ and so there was a good correlation between wear rate and hardness. Also the wear rate of AC/8A20% $Al_2O_3$ composities was obtained the value of $1.65cm^3/cm$ at sliding speed of 1.14m/sec as compared with about $3.0\;{\times}10^{-8}cm^3/cm$ hyereutectie Al-Si alloy(Al-16%Si-2%Cu-1%Fe-1%Ni), which applied presently for piston materials. The wear behavior of $Al_2O_3$ composites was observed to a type of abrasive wear by the SEM view of wear surface.

  • PDF