• 제목/요약/키워드: Room Natural Mode

검색결과 15건 처리시간 0.023초

공조기 덕트 내의 자연대류가 실내 유입유량에 미치는 영향 (The Effect of Flow Rate into Room by Natural Convection in Air Conditioner Duct)

  • 공태우;정한식;정효민
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.160-166
    • /
    • 2001
  • A numerical analysis has been performed for natural convection in an air conditioner duct system. The governing equations were solved a finite volume method using a SIMPLE algorithm. In the calculation mode of duct, the room temperature was preserved at $25.0^{\circ}C$ and duct wall temperature had a temperature of 15, 20.0, 22.5, 23.75, 26.25, 27.5 30 and $35^{\circ}C$. The results of velocity vectors and contours have been represented for various parameters. Based on the numerical data, the relationships between temperature difference and flow rate into room was represented. In the case of $T_\gamma>T_\omega$, the equation for temperature difference and flow rate was $Q=0.0285\triangleT^0.4005$, and in the case of $T_\gamma>T_\omega$, the equation was $Q=0.0099\triangleT^0.4752$. The duct system has an important relation to room temperature and duct wall temperature.

  • PDF

기존의 엔진룸을 이용한 신규 개발 디젤 엔진의 지지계 결정에 관한 연구 (A Study on the Decision of the Mount for the Newly Developed Diesel Engine using the Existing Engine Room)

  • 김규철;김주연;안상호
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.75-85
    • /
    • 1998
  • This paper presents the procedures and technique of the decision on the decision on the mount in a diesel engine development newly. To assess the vibration chara- cteristics of the engine plus transmission, their inertia moments are calculated for three engine versions. i.e., NA(Naturally Aspirated), TC(Turbocharged) and TCI(Turbocharged and Intercooled). These data are used to determine the mount layout and stiffness values affecting the noise quality of an engine as well as a vehicle. The main purpose of this paper is to design the mount rubber having the optimal stiffness characteristics through the investigation of the calculation results and the mount conditions when an engine is installed in a vehicle using the existing engine mount room. Thus, this paper describes the optimal mount positions, rubber stiffnesses, natural frequency, mode shapes and so on using ADAMS program to apply the newly developed engines to three different vehicles.

  • PDF

Free vibration analysis of laminated composite beam under room and high temperatures

  • Cunedioglu, Yusuf;Beylergil, Bertan
    • Structural Engineering and Mechanics
    • /
    • 제51권1호
    • /
    • pp.111-130
    • /
    • 2014
  • The aim of this study is to investigate the effects of the beam aspect ratio(L/h), hole diameter, hole location and stacking layer sequence ($[0/45/-45/90]_s$, $[45/0/-45/90]_s$ and $[90/45/-45/0]_s$) on natural frequencies of glass/epoxy perforated beams under room and high (40, 60, 80, and $100^{\circ}C$) temperatures for the common clamped-free boundary conditions (cantilever beam). The first three out of plane bending free vibration of symmetric laminated beams is studied by Timoshenko's first order shear deformation theory. For the numerical analyses, ANSYS 13.0 software package is utilized. The results show that the hole diameter, stacking layer sequence and hole location have important effect especially on the second and third mode natural frequency values for the short beams and the high temperatures affects the natural frequency values significantly. The results are presented in tabular and graphical form.

카를로스 히메네즈의 'House and Studio'에 보이는 생장성(生長性)의 지역적 의미에 관한 연구 (Study on the meaning of Architectural Growth in Carlos Jim$\acute{e}$nez's "House and Studio")

  • 안준석
    • 한국농촌건축학회논문집
    • /
    • 제14권2호
    • /
    • pp.11-18
    • /
    • 2012
  • Carlos Jimenez's 'House and Studio' was self-designed to fully function as both a home and workplace. Since its establishment in 1983, the installation has been continuously updated for almost 30 years solely under the guidance of the owner's life occurrences and routine needs. The additions and alterations succeeding the building's erection were executed to incorporate small yet symbolic fragments of the resident's memories and life episodes. The particularity of the 'House and Studio' can be compared with other residential remodeling and expansion projects in regards to certain key aspects. These means of comparison include, but are not limited to, building strictly under the direction of a master plan of development vs. allowing natural adaptations that comply with the resident's needs, rapid development vs. gradual advancement, the ornamenting by exposing showy features vs. the enhancing by addition of modest natural components, sustainability vs. sustenance, systematic room divisions vs. ambiguous spatial organization, possession as a materialized asset vs. preservation as a recollection of memories, and finally the recognition as one example of signature architecture vs. the witnessing of a maturing animated shelter. The given propositions can be further explained with the comprehension of Erich Fromm's theory of the 'Having' mode and 'Being' mode, two mechanisms that categorize the essence of human life. The 'Having' mode is described by the human greed for wealth, power, and influence, whereas the 'Being' mode is comprised of compassion, joy, and productivity. Fromm's thesis applies to the general sense of human life, but the ideas can be narrowed to accommodate the architectural standpoint. In architecture, the 'Having' mode can be translated to be the conspicuous form-oriented and self-contained object. The 'Being' mode, on the other hand, is transposed as the more natural form, incorporating the needs of the owner before commercialization. The growth of Jimenez's 'House and Studio' can be perceived as an architectural suggestion to the overcoming of human indifference caused by fixation on the 'Having' mode.

음향모드를 고려한 공동주택 중량충격음 소음해석 (Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode)

  • 문대호;박홍근;황재승;홍건호;임주혁
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

임펄스응답적분법을 이용한 잔향시간의 측정방법이 규준화 바닥충격음레벨에 미치는 영향 (Effect of the Measuring Method of Reverberation Time Using Impulse Response Method on the Normalized Impact Sound Pressure Level)

  • 이주원;권영필
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.34-39
    • /
    • 2006
  • For the evaluation of the normalized impact sound pressure level, the reverberation time of the receiving room should be measured. This paper deals with the effect of the time constant of FFT analyzer and the measuring points on reverberation time. It is found that the time constant should be in the range between 10 ms and 35 ms. While the effect of measuring points on the reverberation time is significant when the bandwidth is narrow it is negligible in the evaluation of the normalized impact sound pressure level.

규준화 바닥충격음레벨 측정시 잔향시간의 편차요인 분석 (Analysis of the Deviation Factor in a Reverberation Time to Measuring the Normalized Impact Sound Pressure Level)

  • 이주원;홍병국;이동훈;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.509-512
    • /
    • 2004
  • 규준화 바닥충격음레벨 평가시 잔향시간은 흡음력 보정을 위해서 필수적으로 고려해야 할 사항이다. 그러나, 잔향시간의 측정 편차가 심하기 때문에 이로 인해 규준화 바닥충격음레벨이 5dB 이상씩 변동하는 경우가 생긴다. 잔향시간 측정 편차의 원인은 실의 형상에 따른 고유모드 분포로 설명할 수 있으며, 측정시 계측기에서의 원인, 특히 동특성에 따라 측정 편차가 심하다는 것을 실험을 통해 알 수 있었다. 또한, 잔향곡선은 직선적인 형태일 경우에 정확한 측정이 가능하나, 저주파수 대역에서는 잔향곡선에 요철이 많이 생기므로 측정 데이터들을 이용하여 잔향시간을 산출할 때 세심한 주의가 요구된다.

  • PDF

창호지의 흡음성능에 관한 실험적 연구 (Sound Absorption Performance of Korean Traditional Window Papers)

  • 최은석;이태강;김항;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2006
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to he standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound absorption characteristics according to difference in thickness and finishing method of window paper and those in sound absorption characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

Characterization of the UV Oxidation of Raw Natural Rubber Thin Film Using Image and FT-IR Analysis

  • Kim, Ik-Sik;Lee, Bok-Won;Sohn, Kyung-Suk;Yoon, Joohoe;Lee, Jung-Hun
    • Elastomers and Composites
    • /
    • 제51권1호
    • /
    • pp.1-9
    • /
    • 2016
  • Characterization of the UV oxidation for raw natural rubber (NR) was investigated in controlled conditions through image and FT-IR analysis. The UV oxidation was performed on a thin film of natural rubber coated on a KBr window at 254 nm and room temperature to exclude the thermal oxidation. Before or after exposure to UV light, image of the NR thin film was observed at a right or tilted angle. FT-IR absorption spectra were measured in transmission mode with the UV irradiation time. The UV oxidation of NR was examined by the changes of absorption peaks at 3425, 1717, 1084, 1477, 1377, and $833cm^{-1}$ which were assigned to hydroxyl group (-OH), carbonyl group (-C=O), carbon-oxygen bond (-C-O), methylene group $(-CH_2-)$, methyl group $(-CH_3)$, and cis-methine group $(cis-CCH_3=CH-)$, respectively. During the initial exposure period, the results indicated that the appearance of carbonyl group was directly related to the reduction of cis-methine group containing carbon-carbon double bond (-C=C-). Most of aldehydes or ketones from carbon-carbon double bonds were formed very fast by chain scission. A lot of long wide cracks with one orientation at regular intervals which resulted in consecutive chain scission were observed by image analysis. During all exposure periods, on the other hand, it was considered that the continuous increment of hydroxyl and carbonyl group was closely related to the decrement of methylene and methyl group in the allylic position. Therefore, two possible mechanisms for the UV oxidation of NR were suggested.