• 제목/요약/키워드: Room Control

검색결과 1,969건 처리시간 0.034초

복강경 수술 후의 반좌위가 수술직후 회복정도에 미치는 영향 (The Effects of Semi-Fowler's Position on Post-Operative Recovery in Recovery Room for Patients with Laparoscopic Abdominal Surgery)

  • 김경아;김영경
    • 성인간호학회지
    • /
    • 제16권4호
    • /
    • pp.566-574
    • /
    • 2004
  • Purpose: To find the effects of semi-Fowler's position on the post-operative recovery for patients with laparoscopic abdominal surgery in recovery room. Method: The research was performed by nonequivalent control group non-synchronized quasi-experimental design. The subjects are forty patients who had laparoscopic abdominal surgery in a hospital from Aug. thru Nov. of 2003. Post-recovery scores and $O_2$saturation degree were measured. The experimental group was place in semi fowler's position while the control group was placed in supine position. The homogeneity between the control group and experimental group was analyzed using the Chi-square, and the hypothesis were tested using t-test. Result: 1. The patients in the experimental group placed in semi fowler's position showed significant higher post-recovery scores than those in the control group who were in a supine position. 2. The patients in the experimental group who were in semi Fowler's position showed no significant higher $O_2$ saturation degree than those in the control group who were in supine position. Conclusion: Based on the results described above, it is considered that the semi-Fowler's position might be effective in enhancing the post-operative recovery score of the patients with laparoscopic abdominal surgery in recovery room.

  • PDF

수술실 간호사의 안전통제감과 간호전문직관 및 소진이 환자안전관리활동에 미치는 영향 (Influence of Safety Control, Nursing Professionalism, and Burnout on Patient Safety Management Activities among Operating Room Nurses)

  • 정해원;이우진
    • 근관절건강학회지
    • /
    • 제30권2호
    • /
    • pp.93-102
    • /
    • 2023
  • Purpose: The purpose of this study was to examine the influence of safety control, nursing professionalism, and burnout on patient safety management activities of operating room nurses. Methods: Data were collected from August 10 to September 26, 2022 from 154 operating nurses who consented to participate and have worked for more than six months in hospitals with 300 or more beds in the Seoul-Incheon area. The data were analyzed using the SPSS/WIN 26.0 program. Results: The main factors affecting patient safety management activities were safety control (β=.36, p<.001) and nursing professionalism (β=.15, p=.046). The regression model was statistically significant (F=13.49, p<.001), with explanatory power of approximately 28.6%. Conclusion: Based on these results, the aforementioned activities can be promoted by preparing and providing an operating room safety management program that can improve safety control and establish proper nursing professionalism.

Dry Room내의 온.습도 분포 해석 (Analysis of Temperature and Humidity Distribution in a Dry Room)

  • 이관수;임광옥;안강호;정영식
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.524-531
    • /
    • 2001
  • The temperature and humidity distribution in a dry room are studied numerically by using standard$\kappa-\varepsilon$ turbulence model. In order to evaluate effective heat and moisture ventilation characteristics inside the room, the heat removal capacity and moisture exhaust efficiency are introduced. An effective ventilation control is analyzed by evaluating quantitatively temperature and humidity distributions. It was found that the mean absolute humidity inside the room was almost constant with approximately 0.1905g/kg air regardless of the models and the heat generation rates. This was believed that the moisture generation by workers was relatively small. 40% improvement of the critical decay time was achieved, through the modifications of design variables.

  • PDF

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

NIC간호중재분류체계를 이용한 수술실 핵심간호중재분석 (Analysis of Core Interventions of Operating Room using Nursing Intervention Classification)

  • 이윤영;박광옥
    • 간호행정학회지
    • /
    • 제8권3호
    • /
    • pp.361-372
    • /
    • 2002
  • Purpose : The purpose of study was to identify to analysis of core nursing interventions performed by Operating Room nurses. Method : The subjects of the study were arbitrarily selected nurses(n=104) working in Operating Room. The period for data collection was 15 days from July, 15, 2002 to July, 30. 2002. The instrument for study was 486 Nursing Interventions Classification developed by McClosky & Bulechek(2000) and was translated into Korean. In 486 nursing interventions, 57 nursing interventions were selected by more than half of 47 professional nurses group of Operating Room. 57 nursing interventions were used as a secondary questionnaire. In the secondary questionnaire, labels and definitions of all 57 interventions were listed. The collected data were self reported by Operating Room nurses. The data were analysed with SPSS program. Result : In 57 nursing interventions, the 'Behavior' domain was the most frequently used. Core interventions of Operating Room were performed several times a day by more than 50% of Operating Room nurses. Core interventions of Operating Room were 16 Core interventions, 7 classes, 5 domains. In the core interventions, the 'Physiological:Complex' domain was the most frequently used. Core interventions of Operating Room were Surgical Preperation, Infection Control:Intraoperative, Surgical Precautions, Fall Prevention, Documentation, Surgical Assistance, Environmental Management:Safety, Skin Surveillance, Physical Restraint, Pressure Ulcer Prevention, Environmental Management:Comfort, Infection Protection, Presence, Emotional Support, Specimen Management, Shift Report. Conclusion : Core interventions of Operating Room have implications for nursing care practice, nursing education, nursing research, and nursing information system in Operating Room.

  • PDF

LRB, FPS 지진격리시스템의 지진응답특성 비교연구 (Seismic Response Comparative Evaluation Study on Floor Isolation using LRB and FPS in Main Control Room of Nuclear Power Plant)

  • 이경진;함경원
    • 한국지진공학회논문집
    • /
    • 제13권4호
    • /
    • pp.15-23
    • /
    • 2009
  • 본 연구에서는 원전 주제어실의 층 지진격리시스템에 대한 지진동 저감성능과 적용성을 평가하기 위해서 실험연구를 수행하였다. 층 지진격리시스템에 적용하기 위해서 납-고무 베어링(LRB)과 마찰진자장치(FPS)를 설계하고 제작하였다. 제어 캐비닛과 액세스 플로어로 구성된 원전 주제어실 부분 실험모형을 제작하여 납-고무 베어링과 마찰진자장치를 각각 설치하여 진동대 실험을 수행하여 지진응답특성을 비교, 평가하였다. 실험을 위해서 원전 주제어실의 운전기준지진(OBE)과 안전정지지진(SSE)의 수평방향 층응답 스펙트럼을 이용하여 인공지진 시간이력을 만들어서 진동대 실험에 사용하였다. 입력지진에 대한 실험모형의 지진응답은 마찰진자장치를 적용한 경우 상대적으로 우수한 지진동 저감특성을 나타냈다.

원전 주제어실 3차원 층 지진격리시스템의 진동대 실험 연구 (Shaking Table Experimental Study on 3-Dimensional Floor Isolation in Main Control Room of Nuclear Power Plant)

  • 이경진;함경원;서용표;윤현도
    • 한국지진공학회논문집
    • /
    • 제12권1호
    • /
    • pp.57-66
    • /
    • 2008
  • 본 연구에서는 원전 주제어실의 3차원 층 지진격리시스템에 대한 지진동 저감성능과 적용성을 평가하기 위해서 실험연구를 수행하였다. 3차원 층 지진격리시스템에 적용하기 위해서 마찰진자시스템과 에어 스프링을 설계하고 제작하였다. 제어 캐비닛과 액세스 플로어, 격자 프레임, 4개의 마찰진자와 에어 스프링으로 구성된 원전 주제어실 부분 실험모형을 2종류 제작하여 층 지진격리시스템의 원전 적용성을 평가하였다. 실험을 위해서 원전 주제어실의 운전기준지진(OBE)과 안전정지지진(SSE)의 수직방향, 수평방향 층 응답 스펙트럼을 이용하여 인공지진 시간이력을 만들어서 진동대 실험에 사용하였다. 입력지진에 대한 실험모형의 지진응답은 비 지진격리에 비해 3차원 층 지진격리시스템을 적용한 경우, 우수한 지진동 저감특성을 나타냈다

모바일 키 및 RCU에 기반한 공유공간 출입관리 시스템 개발 (Development ofn Sharing Space Access Management System based on Mobile Key and RCU(Room Control Unit))

  • 정상중
    • 융합신호처리학회논문지
    • /
    • 제21권4호
    • /
    • pp.202-208
    • /
    • 2020
  • 최근 코로나 19로 인해 비대면의 중요성이 강조되고 있으며, 공유공간의 이용 부분에 대하여도 확대되고 있다. 공유공간 출입관리에 언텍트 체크인 기술을 이용하면 대기시간을 감소시키며, 근무자의 효율을 최적화함에 따라서 운영비 절감효과가 발생한다. 본 논문에서는 모바일 키 및 RCU(Room Control Unit)에 기반한 공유공간 출입관리 시스템을 제안하여 모바일 키를 사용하여 시설에 대한 출입을 진행하고, RCU를 사용하여 시설에 대한 모니터링을 제안한다. 제안시스템은 공유 숙박, 임대 분야(레지던스, 분양형 호텔), 공유 오피스 등을 대상으로 특정 요일과 시간에 일회성 방문자가 있는 경우, 그에 맞는 비밀번호를 모바일 플랫폼 기반으로 전달함으로써 기존 비밀번호에 대한 노출 및 열쇠 전달 등의 불편함을 줄일 수 있는 현장적응형 시스템으로 지원한다. 제안 통합시스템의 동작을 시험하기 위해 사용자의 예약, 입실, 퇴실 등의 상태를 전반적으로 파악하기 위한 시나리오에 따라 테스트를 시행하였으며, 테스트의 신뢰성을 위해 성능지표를 설정하여 각 항목에 대한 100%의 성공률을 도출하였다.

화학공장의 소방안전을 위한 원격감시 제어시스템 개발 (The Development of a remote monitoring and control system for a Fire Protection of Chemical Factory)

  • 김형준
    • 한국응용과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.151-160
    • /
    • 2009
  • At this study, we are developing a possible control system through remote monitoring for fire protection in various chemical factory facilities. It's possible to do real time confirmation of a normal operation presence of the various equipment installed in a chemical factory through the internet network at a fire fighting head office, an area fire department and a chemical factory situation room using this remote monitoring control system. When occurring, abnormal operation is the remote monitoring control system, which can check this immediately and notify the situation room administrator. After it was tested using developed remote monitoring control system, the remote monitoring for which the internet network was used confirmed possible.

대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량 (A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.