• Title/Summary/Keyword: Roofs

Search Result 330, Processing Time 0.029 seconds

Rainfall Harvesting as an Alternative Water Supply in Water Stressed Communities in Aguata-Awka Area of Southeastern Nigeria

  • Okpoko, Ephraim;Egboka, Boniface;Anike, Luke;Okoro, Elizabeth
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.95-101
    • /
    • 2013
  • Alternative sources of water are sought in some water stressed communities in the study area. The study focuses on the Aguata-Awka area of southeastern Nigeria. Aquifers occur at great depths, and surface waters may be far from homesteads. The scarcity of water has necessitated the people to adopt various local technologies for harvesting rainfall. The local technology includes collecting rainwater from roofs and channeling the water into large underground tanks, shallow wells and surface reservoirs. Large concrete tanks of $6m{\times}6m{\times}4m$ dimensions are often built underground and can store $144m^3$ of water. Surface reservoirs built on 4 m concrete pillar supports having dimensions of $10m{\times}10m{\times}4m$ and have a storage capacity of $400m^3$. Water samples were collected at 3 different locations of Agulu, Ekwulobia, and Awka and were analyzed for their physical, chemical, and bacteriological parameters. Results indicate a range of values for pH, 5.9 to 7.1; turbidity, 0.9 to 2.7; total dissolved solids, 80 to 170 mg/L; total hardness, 4.5 to 6.4 mg/L; magnesium, 1.2 to 1.4 mg/L; bicarbonate, 19.4 to 83.6 mg/L; and sulfate, 3.6 to 6.4 mg/L. Bacteriological analysis results were negative for fecal and total coliform counts. All parameters, with the exception of pH where aluminum and galvanized iron roofs are used for collection, fall within the recommended guidelines for drinking water quality of the World Health Organization, and the Standard Organization of Nigeria, new Nigerian standards for drinking water quality. Magnesium is above the maximum permitted level for consumer acceptability of the Nigerian standards for drinking water quality. The water can be classified as fresh moderately hard and soft. The water can be described as a calcium and bicarbonate type.

A Study on Electric Capacity and CO2 by the Roof Top PV System of the Industrial Building in Korea (한국 산업용 건물지붕 적용 PV에 의한 발전량 및 CO2 분석연구)

  • Kim, Ji-Su;Lee, Eung-Jik;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.131-136
    • /
    • 2010
  • The purpose of this study is to provide foundational data for expansion of solar generation in building application, a clean energy, by introducing applicability of solar power generation system on roofs of industrial buildings and computing expected amounts of power and carbon dioxides reduction. As methodologies of this study, after reviewing 120,000 domestic factories to verify the BIPV feasibility for industrial building sthrough theoretical considerations of solar generation system, we calculated BIPV application methods and subsequent expected power generation quantity and carbon dioxide reductions through roof type analysis. we analyzed four cases of expected power generation amounts of solar batteries according to application methods, and when considering that the main type of roofs are slant roofs according to the investigation result about roof forms of domestic industrial complexes, we believe that the module angle of a slant roof around $17^{\circ}$(case3) is most suitable for the application. Finally, we came up with 517,944[TOE] as the corresponding petroleum tonnage based on this computed expected power generation amount and the amount of 1,214,836[$tCO_2$] carbon dioxide reductions by calculating them by energy sources.

A Study on the Type and Spread of Framed Structure of Gable Roof Meeting at Right Angle in the early Joseon Dynasty (조선전기 맞배직교형 건축의 유형과 전파)

  • Kim, Bue-Dyel;Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.27 no.2
    • /
    • pp.39-50
    • /
    • 2018
  • This study investigates the types and spread of framed structures of gable roofs meeting at right angle showed in old architecture and documentary paintings of houses, which were well liked in the early Joseon Dynasty. The conclusions of this study were as follows. First, the framed structure of gable roof meeting at right angle can be divided or recognized in 4 types according to their structure's size and purlin's position. Three of those types were noted to be in Seoul. Second, the framed structure of gable roofs meeting at right angle begun from the awareness of their independence from one another. Each space was divided based on their functions. Therefore, it could be extended in various forms, not only in the square plan physique but also in many different forms. And allowed free plan configuration regardless of column layouts or size of structure. Third, 5 purlins and 3 purlins crossing structure were preferred in Han-yang, the early Joseon Dynasty. It is related to the specific construction conditions of urban houses, such as the slope of land, limited land area, and economic power. Fourth, urban housing techniques were diffused throughout the country by officials who lived in Kae-gyeong and Han-yang at the end of Goryeo and early Joseon Dynasty. In other regions, framed structure of gable roof meeting at right angle households decreased, but in some regions of Gyeongsang-province, framed structure of gable roof meeting at right angle has maintained with Staggered purlin.

Change of Vegetation and Soil Characteristics of Green Roofs in Dongguk University (동국대학교 옥상녹화 지역의 식생 및 토양특성 변화)

  • Lee, Sang-Jin;Park, Gwan-Soo;Kim, Dong-Il;Lee, Dong-Kun;Kil, Sung-Ho;Jang, Seong-Wan;Park, Beom-Hwan;Yun, Jun-Young;Jang, Kwan-Woo;Lee, Ho-Young;Kwon, Oh-Jung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.1
    • /
    • pp.193-206
    • /
    • 2013
  • This study was to provide the base data on the status of vegetations and soils in green roofs by analyzing the soil and vegetation characteristics of 4 green roofs in Dongguk University in September 2012. Sanglokwon(SW), Dongguk Hall(DH), University Library(UL), and Information and Culture Hall P(IC) were established in 2005, 2008, 2009, and 2010, respectively. The areas of green roofs were $700m^2$, $2,300m^2$, $1,240m^2$, and $640m^2$ in SW, DH, UL, and IC respectively. The investigated floras of vascular plants were 26 families, 55 genera, 65 species in Sanglokwon(SW), 53 families, 99 genera, 112 species in Dongguk Hall(DH), 43 families, 77 genera, 84 species in University Library(UL), and 41 families, 71 genera, 75 species in Information and Culture Hall P(IC), respectively. A positive correlation is shown between the number of plant species and planting area. Total nitrogen, organic matter, and potassium in soil have positive correlation with the number of plant species. The number of plant species was proportional to area and increased more than twice after planting. About a quarter of the invaded plants (including native and naturalized species) were naturalized plants. The total soil depths including vegetation soil and drainage soil at SW, DH, UL, and IC were 20cm, 10cm, 10cm, and 8cm, respectively. The depths of vegetation soil at SW, DH, UL, and IC were <7cm, <3cm, <2cm, and <2cm respectively. The soil pH in vegetation soil ranged from 5.22 to 5.36, and from 6.13 to 6.39 in drainage soil. Available-P concentration ranged from 10.17 to 189.77mg/kg in vegetation soil and from 6.70 to 81.17mg/kg in drainage soil. Carbon concentration in vegetation soil ranged from 2.93 to 9.70%, and 2.93 to 9.70% in drainage soil. Carbon contents in 20cm, 10cm, 10cm, and 8cm soil depths were $2.62kg/m^2$, $1.89kg/m^2$, $0.50kg/m^2$, and $0.53kg/m^2$ at SW, DH, UL, and IC, respectively.

The Residents' Needs for Establishing Direction Korean Rural Viewscape Houses (농촌 경관주택의 방향 설정을 위한 거주자 요구 조사)

  • Choi Byoung-Sook;Ryo Ok-Soon;Oh Chan-Ohk;Park Yoon-Ho;Chon Young-Mi
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.17-28
    • /
    • 2005
  • The purpose of this study was to find out the residents' needs fur rural houses and to suggest the policy directions for developing Korean rural viewscape houses. The subjects were 386 houses and residents. They were selected according to accessibility, area characteristics, administrative district, and village types. The data were collected by using the interview and observation method based on the questionnaire. By analyzing the residents' needs for rural houses, the following conclusions were derived: 1) In order to preserve the rural characteristic, the government should lead to establish the yard space and the exterior design factors such as wall material and color, and the shape, material, and color of roof. 2) At the same time, the government should provide the residents with the subsidy for house improvement, so that they can build the desirabe size of house and the aged remodel their houses. 3) The contemporary design model of rural Han-ok should be developed and built. 4) The new rural house model improving roof design should be developed, because present houses with slab roofs and skirt roofs spoil the harmony with the rural natural environment. 5) The direction of rural houses for viewscape was defined as to satisfy residents' needs for convenient housing lift and to harmony visual and physical factors - building form, material and color - involving Korean rural housing culture.

Comparative Evaluation of Cool Surface Ratio in University Campus: A Case Study of KNU and UC Davis (대학 캠퍼스의 쿨표면 비율 비교평가: 경북대학교와 UC Davis를 사례로)

  • Hwang, Young-Seok;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.117-127
    • /
    • 2015
  • The cool surface ratio could be used as a proxy of the overall thermal environment contributing to heat islands in urban area. This research proposes a comparative evaluation framework in an objective and quantitative way for measuring cool surface ratios. Two university campuses (Kyungpook National University: KNU, South Korea and UC Davis: University of California, Davis, USA) were selected as case study sites in order to monitor cool surface condition. Google Earth combined with digital maps realistically identified the major type of cool surfaces such as cool roofs and water bodies in the study area. Cool surfaces were sparsely identified over the KNU campus while the UC Davis campus was heavily covered by cool surfaces such as cool roofs and water bodies, resulting in almost four times more first-grade cool surfaces, as compared to KNU. It is confirmed that standard remote sensing technology can offer the viable method of measuring and comparing the campus-wide cool surface condition. It is anticipated that this research output could be used as a valuable reference to initiate a nation-wide cool surface strategy since objective evidence has been provided based on area-wide measurement for the cool surface in the two university context.

Wind Pressure Spectra for Circular Closed and Open Dome Roofs (원형 밀폐 및 개방형 돔 지붕의 풍압 스펙트럼)

  • Cheon, Dong-jin;Kim, Yong-Chul;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • Wind tunnel tests were conducted to analyze the wind fluctuating pressures on a circular closed and open dome roof with a low span rise. Two dome models with various geometric parameters (height/span ratios and open ratios) were used for fixed span rise ratio dome and wind pressure spectrum were analyzed. The applicability was examined in comparison with the spectral model proposed in the previous studies. The analysis results show that the wind pressure spectrum of open dome roof tends to increase power in the high frequency range and the second peak is found in the area different from the closed dome roof. In addition, according to the comparison analysis with the previous proposed spectral model, it was found that it is not applicable to the closed and open dome roofs with low rise ratio due to the different peak frequencies.

Estimation of the Available Green Roof Area using Geo-Spatial Data (공간정보를 이용한 옥상녹화 가용면적 추정)

  • Ahn, Ji-Yeon;Jung, Tae-Woong;Koo, Jee-hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.5
    • /
    • pp.11-17
    • /
    • 2016
  • The purposes of this research are to estimate area of greenable roof and to monitor maintaining of green roofs using World-View 2 images. The contents of this research are development of World-View 2 application technologies for estimation of green roof area and development of monitoring and maintaining of green roofs using World-View 2 images. The available green roof areas in Gwangjin-gu Seoul, a case for this study, were estimated using digital maps and World-View 2 images. The available green roof area is approximately 12.17% ($2,153,700m^2$) of the total area, and the roof vegetation accounts for 0.46% ($80,660m^2$) of the total area. For verification of the extracted roof vegetation, Vworld 3D Desktop map service was applied. The study results may be used as a decision-making tool by the government and local governments in determining the feasibility of green roof projects. In addition, the project implementer may periodically monitor to see whether roof greening has maintained for efficient management of projects, and a vast amount of World-View 2 images may be regularly used before and after the projects to contribute to sharing of satellite images information.

A Study on the Urban Heat Simulation Model Incorporating the Climate Changes (기후변화가 반영된 도시 열환경 시뮬레이션 모델의 연구)

  • Kang, Jonghwa;Kim, Wansoo;Yun, Jeongim;Lee, Joosung;Kim, Seogcheol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.697-707
    • /
    • 2018
  • A fast running model comprising the climate change effects is proposed for urban heat environment simulations so as to be used in urban heat island studies and/or the urban planning practices. By combining Hot City Model, a high resolution urban temperature prediction model utilizing the Lagrangian particle tracing technique, and the numerical weather simulation data which are constructed up to year of 2100 under the climate change scenarios, an efficient model is constructed for simulating the future urban heat environments. It is applicable to whole city as well as to a small block area of an urban region, with the computation time being relatively short, requiring the practically manageable amount of the computational resources. The heat environments of the entire metropolitan Seoul area in South Korea are investigated with the aid of the model for the present time and for the future. The results showed that the urban temperature gradually increase up to a significant level in the future. The possible effects of green roofs on the buildings are also studied, and we observe that green roofs don't lower the urban temperature efficiently while making the temperature fields become more homogeneous.

Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof (평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서)

  • Ryu, Taek Hyoung;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.