• Title/Summary/Keyword: Roof green unit system

Search Result 5, Processing Time 0.02 seconds

Thermal Property of the Roof Green Unit System Using Artificial Lightweight Soil Recycled with Bottom Ash (바텀애시 재활용 인공토양 적용 옥상녹화 유니트 시스템의 열특성)

  • Yoo, Jong-Su;Lee, Jong-Chan;Oh, Chang-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.49-55
    • /
    • 2020
  • In this study, the surface temperature of the roof green system using ALSRBA(Artificial Lightweight Soil Recycled with Bottom Ash) was measured in each season and the thermal property of the ALSRBA was investigated. As a result, it was certified that ALSBRA has superior thermal property than the usual artificial soil. In addition, The daily temperature range in each season was measured to investigate the thermal isolation property of EUS(Existing Unit System) and DUS(Developed Unit System). The result showed that the thermal isolation effect of EUS was lower than that of SPSS(Site-Place-Soil System), but thermal isolation effect of DUS was similar to that of SPSS because DUS has continuous ALSBRA layer by removing unit barrier.

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet (엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • According to the increment of urban buildings, the demand of eco-environment space will be also increased. Therefore, the artificial ground green system on a roof will be supplied gradually. In this study, the concept of simplification, unification and prefabrication was widely applied to supply green system. Consequently, the box unit system with a continuous soil layer was developed, and adhesive property, wind resistance and insulation property of this system were evaluated for site application. As a results of adhesive property and wind resistance test, comparing with design wind pressure and wind velocity, this system was safe at the height of 100m building located in urban. In addition, results of temperature measurement for 120 days showed 17% higher insulation property at daytime and 45% higher insulation property at night than normal box unit system owing to continuous soil layer.

Present Condition and Preferences on Well-being Elements in Apartments (아파트의 웰빙요소 도입현황과 선호도)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2007
  • The purposes of this study were to summarize the concept of well-being and well-being apartment, to grasp the present condition of apartments which were introduced with well-being elements, and to find out the consumer preferences on well-being elements for apartment planning. Library and internet surveys were performed to summarize the concept of well-being and well-being apartment and to grasp the present condition of apartments which were introduced with well-being elements. Questionnaire survey was carried out from 2nd to 22nd of June 2005, to investigate the preferences on well-being elements for apartment planning. The respondents were 250 residents who are from thirties to fifties and living in urban area. As results, respondents think that 'living for health of body and mind' about concept of well-being and 'certificated apartments by green building rating system' or 'apartments introduced ecological factor' about concept of well-being apartment. They answered that 'yes' about 'Do you have intention to buy well-being apartment?'. The elements in aspect of complex planning having the preference were revealed that promenade for complex design, ecological garden or walking space for landscape design, outdoor exercise space for outdoor design, and security system for foundation equipment. The elements having the preference in aspect of public facilities were fitness room for sports & health facility and study room for cultural facility. The preferred elements in aspect of building and unit design were roof garden for building design, multi-functional room for unit floor plan, natural surface material for interior surface, ventilation system for indoor environment, control system for home automation, and food waste machine for home electronics.

A Study of Potential Buyers' Consciousness of Single-Family Housing in Ulsan (단독주택에 대한 울산시 거주자의 주의식 연구)

  • Kim, Ji-Suk;Yang, Se-Hwa
    • Journal of Families and Better Life
    • /
    • v.28 no.6
    • /
    • pp.35-46
    • /
    • 2010
  • The purpose of the study was to identify the potential buyers' consciousness of single-family housing to provide useful data to help future single-family housing supplies in Ulsan. The study selected residents in Ulsan, who were over twenty and had an interest in living in a single-family housing. A survey was conducted from September 11, 2008 to September 25, 2008. The sample consisted of 364 persons who are currently live in Ulsan metropolitan area. The results are as following. About two thirds of the sample had the desire to live in a single-family housing. Moving into a single-family housing had financial preparation as the greatest issue. When moving into a single-family housing, the convenience of the residential district was the greatest consideration, whether or not it is a green environment, pollution level, etc. The potential buyers valued environment-friendly features and also had a very strong desire to own their own house. Many of them wanted to design and build their own single-family housing within a budget of 100-200 million KRW. In terms of the location, there was a higher preference for the riverside or lakeside rural areas outside the city. In terms of size, the preference was less than $330m^2$, which includes $99-132m^2$ for residential. When considering a single-family housing the direction was the most important feature, along with eco-friendly and safer materials and equipments. When building the single-family housing the potential buyers considered the community spaces first with a preference for having three bedrooms and two bathrooms. For the exterior, they wanted a unique shape of roof and there were high preferences for brown and beige colors. In terms of housing complexes, the potential buyers preferred individual unit types over complexes. If they preferred housing complexes, they wanted the cluster form complex with about 10-30 units. The complex also required a park-like setting with a guard system, which shows that convenience and safety were the most important features. In terms of complex management, they considered environmental management as the most important feature. The potential buyers were willing to pay belw 200,000 KRW, which showed their desire to minimize financial burdens.