• Title/Summary/Keyword: Robustness Control

Search Result 1,769, Processing Time 0.029 seconds

Robust model reference direct adaptive pole placement control

  • Kim, Jong-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.872-877
    • /
    • 1990
  • Robustness of a model refernece direct adaptive pole placement control for not necessarily minimum phase systems is studied subject to unmodeled dynamics and bounded disturbances. The adaptive control scheme involves two estimators for the system and the controller parameter estimation, respectively. The robustness is obtaind under some weak assumptions and by using both a normalized least-squares algorithm with dead zone and an appropriate nonlinear feedback.

  • PDF

A study on improvement of robustness in adaptive control (적응제어에 있어서의 robustness 개선을 위한 방법에 관한 연구)

  • 김홍필;민병태;양해원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.182-184
    • /
    • 1987
  • When a .epsilon.$_{1}$-modification is applied to a plant with unmodeled dynamics and bounded output disturbance, the output error seems to be relatively large. A .epsilon.$_{1}$-modification with the same switching action as in the switching a modification is proposed to reduce the output proposed adaptive control scheme is to a second-oder plant and it can be asserted that the control objective is satisfied.

  • PDF

Robust Position Control of DC Motor Using Neural Network Sliding Mode Controller (신경망 슬라이딩 모드 제어기를 이용한 직류 전동기의 강인한 위치제어)

  • 전정채;최석호;박왈서
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.122-127
    • /
    • 1998
  • Robust control for DC motor is needed according to the highest precision of industrial automation. However, when a motor control system has an effect of load disturbance, it is very difficult to guarantee the robustness of control system. The sliding mode control has robustness, but the discontinuous control law in sliding mode control with robustness leads to undesirable chattering in practice. As a method solving this problem, in this paper, neural network sliding mod control method for motor control system is presented. The proposed controller effectively can eliminate load disturbance without chattering. The effectiveness of the control scheme is verified by simulation results.

  • PDF

A study on Communication Robustness Testing for Industrial Control Devices (산업용 제어기기의 통신 견고성 시험 방안 연구)

  • Park, Kyungmi;Shin, Donghoon;Kim, WooNyon;Kim, SinKyu
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.1099-1116
    • /
    • 2019
  • Industrial control systems(ICS) are widely used in various industrial area and critical infrastructure. To mitigate security threats on ICS, the security assurance test for industrial control devices has been introduced and operating. The test includes testing of the security function of the device itself and testing of communication robustness. In this paper, we describe the security requirements of EDSA, Achilles, and Korea's TTA standard(security requirements for ICS). And also, we analyzed the characteristics of communication robustness test(CRT) of each certification. CRT verifies the device's operation of essential function while transmitting fuzzing and stress packets. Existing test methods are mostly focused on the embedded devices and are difficult to apply to various devices. We propose a method to test communication robustness which reflect the characteristics of control H/W, control S/W, field devices and network devices in ICS. In the future, we will apply the proposed communication robustness test to actual products and present solutions for arising issues.

Robust passive damper design for building structures under uncertain structural parameter environments

  • Fujita, Kohei;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.3 no.6
    • /
    • pp.805-820
    • /
    • 2012
  • An enhanced and efficient methodology is proposed for evaluating the robustness of an uncertain structure with passive dampers. Although the structural performance for seismic loads is an important design criterion in earthquake-prone countries, the structural parameters such as storey stiffnesses and damping coefficients of passive dampers are uncertain due to various factors or sources, e.g. initial manufacturing errors, material deterioration, temperature dependence. The concept of robust building design under such uncertain structural-parameter environment may be one of the most challenging issues to be tackled recently. By applying the proposed method of interval analysis and robustness evaluation for predicting the response variability accurately, the robustness of a passively controlled structure can be evaluated efficiently in terms of the so-called robustness function. An application is presented of the robustness function to the design and evaluation of passive damper systems.

A Backstepping Control of LSM Drive Systems Using Adaptive Modified Recurrent Laguerre OPNNUO

  • Lin, Chih-Hong
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.598-609
    • /
    • 2016
  • The good control performance of permanent magnet linear synchronous motor (LSM) drive systems is difficult to achieve using linear controllers because of uncertainty effects, such as fictitious forces. A backstepping control system using adaptive modified recurrent Laguerre orthogonal polynomial neural network uncertainty observer (OPNNUO) is proposed to increase the robustness of LSM drive systems. First, a field-oriented mechanism is applied to formulate a dynamic equation for an LSM drive system. Second, a backstepping approach is proposed to control the motion of the LSM drive system. With the proposed backstepping control system, the mover position of the LSM drive achieves good transient control performance and robustness. As the LSM drive system is prone to nonlinear and time-varying uncertainties, an adaptive modified recurrent Laguerre OPNNUO is proposed to estimate lumped uncertainties and thereby enhance the robustness of the LSM drive system. The on-line parameter training methodology of the modified recurrent Laguerre OPNN is based on the Lyapunov stability theorem. Furthermore, two optimal learning rates of the modified recurrent Laguerre OPNN are derived to accelerate parameter convergence. Finally, the effectiveness of the proposed control system is verified by experimental results.

The Generator Excitation Control Based on the Quasi-sliding Mode Pseudo-variable Structure Control

  • Hu, Jian;Fu, Lijun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1474-1482
    • /
    • 2018
  • As an essential means of generator voltage regulation, excitation control plays an important role in controlling the stability of the power system. Therefore, the reasonable design of an excitation controller can help improve the system stability. In order to raise the robustness of the generator exciting system under outside interference and parametric perturbation and eliminate chattering in the sliding mode control, this paper presents a generator excitation control based on the quasi-sliding mode pseudo-variable structure control. A mathematical model of the synchronous generator is established by selecting its power, speed and voltage deviation as state variables. Then, according to the existing conditions of the quasi-sliding mode, a quasi-sliding mode pseudo-variable structure controller is designed, and the parameters of the controller are obtained with the method of pole configuration. Simulations show that compared with the existing methods, the proposed method is not only useful for accurate voltage regulation, but also beneficial to improving the robustness of the system at a time when perturbance happens in the system.

A Tracking Controller for Robot Manipulator Using Sliding Mode Control (슬라이딩 모드를 이용한 로봇 메니플레이터의 추적제어기)

  • 이정훈;이주장;윤명중;권우현
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.5-12
    • /
    • 1996
  • In this paper, we design a Continuous Variable Structure Controller which can control robot manipulators to follow the desired planned trajectory with accuracy and robustness, and improve continuity and robustness of variable structure control, based on disturbance observer. We also analyze the stability the proposed algorithm and then verify the usefulness and performance through simulation stuies.

  • PDF

The robustness of continuous self tuning controller for retarded system

  • Lee, Bongkuk;Huh, Uk Youl
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1930-1933
    • /
    • 1991
  • In this paper, the robustness of self turning controller on the continuous time-delay system is investigated. The polynomial identification method using continuous time exponentially weighted least square algorithm is used for estimating the time.-delay system parameters. The pole-zero and pole placement method are adopted for the control algorithm. On considering the control weighting factor and reliability filter the effect of unmodeled dynamics of the plant are examined by the simulation.

  • PDF

Flow Control of ATM Networks Using $H_{\ifty}$ Method ($H_{\ifty}$ 이론을 이용한 ATM 망의 흐름 제어)

  • Gang, Tae-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.8
    • /
    • pp.617-622
    • /
    • 2000
  • In this paper proposed is an $H_{\ifty}$ based flow controller for the ATM networks. The round trip time-delay uncertainty is taken into account and robustness of the proposed controller is analyzed. Maximum allowable time-delay uncertainties are computed with different weightings on performance and robustness. And discussed is a time-domain implementation method of the proposed controller. Time domain simulation with realistic environment demonstrates that the performance of the proposed controller is much better than that of conventional one.

  • PDF