• Title/Summary/Keyword: Robot-assisted surgery

Search Result 58, Processing Time 0.023 seconds

Research on Computer-aided and Robotic-assisted Surgery of Fracture Reduction and Bone Deformity Correction under External fixation (외고정법을 이용한 컴퓨터이용 및 로봇지원 골절수술 및 골변형교 정술에 대한 연구)

  • Kim Y.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.131-134
    • /
    • 2005
  • This paper presents a computer-aided simulation and robotic-assisted execution technology of external fixation method to achieve fracture reduction and deformity correction in long bones. Combining the kinematic analysis with a graphic model of the tibia and the fixator allowed 3D simulation and visualization of the adjustments required to reduce fracture or correct bone deformity as a pre-operative planning tool. The developed robot model provided accurate deformity correction with small residual deformity based on the results of the planning. By incorporating the robot model with image-guided system and computer-aided planning, the integrated system could be useful for computer-aided pre-operative planning and robotic-assisted execution in fracture treatment and bone deformity surgery.

  • PDF

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

Impedance Model based Bilateral Control for Force reflection of a Laparoscopic Surgery Robot (복강경 수술 로봇의 힘 반향을 위한 임피던스 모델 기반의 양방향 제어)

  • Yoon, Sung-Min;Kim, Won-Jae;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.801-806
    • /
    • 2014
  • LAS (Laparoscopy Assisted Surgery) has been substituted alternatively for traditional open surgery. However, when using a commercialized robot assisted laparoscopic such as Da Vinci, surgeons have encountered some problems due to having to depend only on information by visual feedback. To solve this problem, a haptic function is required. In order to realize the haptic teleoperation system, a force feedback and bilateral control system are needed. Previous research showed that the perturbation value estimated by a SPO (Sliding Perturbation Observer) followed a reaction force that loaded on the surgical robot instrument. Thus, in this paper, the force feedback problem of surgical robots is solved through the reaction force estimation method. This paper then introduces the possibility of the haptic function realization of a laparoscopic surgery robot using a bilateral control system. For bilateral control, the master uses an impedance control and the slave uses a SMC (Sliding Mode Control). The experiment results show that a torque and force sensorless teleoperation system can be implemented using a bilateral control structure.

Robotic harvest of a latissimus dorsi flap using a single-port surgical robotic system in breast reconstruction

  • Joo, Oh Young;Song, Seung Yong;Lew, Dae Hyun;Park, Hyung Seok;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.577-582
    • /
    • 2021
  • Robot-assisted surgery is evolving to incorporate a higher number of minimally invasive techniques. There is a growing interest in robotic breast reconstruction that uses autologous tissue. Since a traditional latissimus dorsi (LD) flap leads to a long donor scar, which can be an unpleasant burden to patients, there have been many attempts to decrease the scar length using minimally invasive approaches. This study presents the case of a patient who underwent a robot-assisted nipple-sparing mastectomy followed by immediate breast reconstruction with an LD flap using a single-port robotic surgery system. With the assistance of a single-port robot, a simple docking process using a short and less visible incision is possible. Compared to multiport surgery systems, single-port robots can reduce the possibility of collision between robotic arms and provide a clear view of the medial border of the LD where the curvature of the back restricts the visual field. We recommend the use of single-port robots as a minimally invasive approach for harvesting LD flaps.

Is Robot-Assisted Surgery Really Scarless Surgery? Immediate Reconstruction with a Jejunal Free Flap for Esophageal Rupture after Robot-Assisted Thyroidectomy

  • Park, Seong Hoon;Kim, Joo Hyun;Lee, Jun Won;Jeong, Hii Sun;Lee, Dong Jin;Kim, Byung Chun;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.550-553
    • /
    • 2017
  • Esophageal perforation is a rare but potentially fatal complication of robot-assisted thyroidectomy (RAT). Herein, we report the long-term outcome of an esophageal reconstruction with a jejunal free flap for esophageal rupture after RAT. A 33-year-old woman developed subcutaneous emphysema and hoarseness on postoperative day1 following RAT. Esophageal rupture was diagnosed by computed tomography and endoscopy, and immediate surgical exploration confirmed esophageal rupture, as well as recurrent laryngeal nerve injury. We performed a jejunal free flap repair of the 8-cm defect in the esophagus. End-to-side microvascular anastomoses were created between the right external carotid artery and the jejunal branches of the superior mesenteric artery, and end-to-end anastomosis was performed between the external jugular vein and the jejunal vein. The right recurrent laryngeal nerve injury was repaired with a 4-cm nerve graft from the right ansa cervicalis. Esophagography at 1 year after surgery confirmed that there were no leaks or structures, endoscopy at 1 year confirmed the resolution of vocal cord paralysis, and there were no residual problems with swallowing or speech at a 5-year follow-up examination. RAT requires experienced surgeons with a thorough knowledge of anatomy, as well as adequate resources to quickly and competently address potentially severe complications such as esophageal rupture.

Traditional Korean Medicine Treatment for Sequelae After Surgery in Prostate Cancer Patients: Two Case Report (전립선암환자의 수술 후 발생한 후유증에 대한 한방치료 2례)

  • Jang, Kwon-jun;Yang, Jung-min;Hwang, Woo-seok;Lee, Beom-joon
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.5
    • /
    • pp.795-808
    • /
    • 2022
  • Objectives: The purpose of this study is to report two cases of prostate cancer patients whose side effects after surgery were treated with traditional Korean medicine. Methods: Two prostate cancer patients underwent robot-assisted laparoscopic prostatectomy, and both patients were treated with traditional Korean medicine. Subjective discomfort symptoms were evaluated using the Numerical Rating Scale. Adverse events were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 5.0. Daily life vitality was evaluated by the Eastern Cooperative Oncology Group. Results: After treatment with traditional Korean medicine, discomfort symptoms that occurred after surgery, such as frequent urination, nocturia, insomnia, and depression, all gradually improved, and Eastern Cooperative Oncology Group scores also improved from two points to one point. Additionally, there were no hematologic side effects from the traditional Korean medicine treatment. Conclusions: This case study suggests that traditional Korean medicine may contribute to the improvement of side effects caused by robot-assisted laparoscopic prostatectomy, quality of life, and immunity.

Robot assisted THA surgery using gauge based registration (게이지 정합 방법을 이용한 소형 인공고관절 수술로봇의 개발)

  • Shin, Ho-Chul;Park, Young-Bae;Yoon, Yong-San;Kwon, Dong-Soo;Lee, Jung-Ju;Won, Chung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.482-484
    • /
    • 2001
  • In orthopedics, hip arthroplasty is the operation that replaces damaged hip joint to artificial joint. In hip arthroplasty, quite better result can be achieved if robot is applied to machine cavity in bone, especially when cementless stem is used. So several kinds of robots were introduced for hip arthroplasty, but they used MRI, CT Scan, vision analysis and real time tracking of bone position for registration of robot. To overcome shortage of conventional robot surgery, gauge based registration method was proposed and small robot was designed. In this method, small robot is mounted on femur, and its position is determined by gauge registration method. Operation procedure was performed on model femur and result was analyzed. This robotic hip surgery system is expected to more adaptable in operation room.

  • PDF

Effectiveness and Safety of Robot-Assisted Brain Stereotactic Surgery: A Systematic Review (뇌정위 수술 보조 로봇 시스템의 안전성과 유효성: 체계적 문헌고찰)

  • Park, Sun-young;Jeon, Mi Hye
    • The Journal of Health Technology Assessment
    • /
    • v.6 no.2
    • /
    • pp.142-147
    • /
    • 2018
  • Objectives: The purpose of this study is to evaluate the safety and effectiveness of Robot-Assisted Brain Stereotactic Surgery with a systematic review. Methods: Electronic literature was searched using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library on 6th April 2017. Two authors screened 1218 citations. Duplicated articles of 456 excluded, the remaining 762 articles were reviewed with title and abstract. Results: A total of 8 studies were selected in this review. The device used in all studies was $ROSA^{TM}$. In one cohort study comparing the intervention ($ROSA^{TM}$) with the control (conventional stereotactic surgery), hematoma was reported no significant difference between groups. In six descriptive studies, one study reported hematoma 10% (10/100) and temporary nerve impairment 6% (6/100) using the ROSA; while five descriptive study did not report any complications. In one cohort, the localization precision were 1.2 mm in the intervention group and 1.1 mm in the control group; the localization success rate as 78.2% in the intervention group and 76.2% in the control group in one cohort; and the average time for surgery as 130 min for the intervention group and 352 min for the control group in one cohort. Four studies reported the localization success rate as 100%; two out of three articles reported the overall time for surgery as 56 min and 90 min, while one article reported the time as less than one hour in 50% of patients (50/100); two articles reported in epilepsy patients, the condition after the surgery was Engel level I in 66.2%, 75% patients, Engel level II-III in 25%, 26.5% patients, and Engel level 4 in 7.3% patients. Conclusion: Robot-Assisted Brain Stereotactic Surgery is a safe and accurate technique that can significantly reduce the time for the brain stereotactic surgery. However, further studies are needed to generalize the results.

$DaVinci^{TM}$ S robot-assisted esophagectomy in a 83-year-old patient with esophageal cancer (고령의 식도암 환자에서 다빈치 S 로봇을 이용한 식도 절제술)

  • Haam, Seok-Jin;Park, Seong-Yong;Paik, Hyo-Chae
    • Korean Journal of Bronchoesophagology
    • /
    • v.14 no.2
    • /
    • pp.53-56
    • /
    • 2008
  • The postoperative respiratory complications such as pneumonia and ARDS, are poor prognostic factors after esophagectomy in patients with esophageal cancer. To avoid these complications, there have been attempts to use minimally invasive approach. Recently introduced daVinciTM S surgical system is used in esophagectomy because of its advantages of minimal invasiveness, clear 3-dimensional imaging and precise handling of robotic arms. We report a 83-year-old esophageal cancer patient who underwent daVinciTMS robot-assisted esophagectomy, laparoscopic stomach mobilization followed by cervical esophagogastrostomy.

  • PDF