• 제목/요약/키워드: Robot calibration

검색결과 208건 처리시간 0.028초

원형 물체를 이용한 로봇/카메라 자세의 능동보정 (Active Calibration of the Robot/camera Pose using Cylindrical Objects)

  • 한만용;김병화;김국헌;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제5권3호
    • /
    • pp.314-323
    • /
    • 1999
  • This paper introduces a methodology of active calibration of a camera pose (orientation and position) using the images of cylindrical objects that are going to be manipulated. This active calibration method is different from the passive calibration where a specific pattern needs to be located at a certain position. In the active calibration, a camera attached on the robot captures images of objects that are going to be manipulated. That is, the prespecified position and orientation data of the cylindrical object are transformed into the camera pose through the two consecutive image frames. An ellipse can be extracted from each image frame, which is defined as a circular-feature matrix. Therefore, two circular-feature matrices and motion parameters between the two ellipses are enough for the active calibration process. This active calibration scheme is very effective for the precise control of a mobile/task robot that needs to be calibrated dynamically. To verify the effectiveness of active calibration, fundamental experiments are peformed.

  • PDF

선형 반복법에 의한 이동로봇의 동시 보정 (Simultaneous Mobile Robot Calibration using Iterative Linear Method)

  • 김영용;정문호
    • 한국전자통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.793-800
    • /
    • 2015
  • 이동 로봇 Pan-Tilt 기구부에 장착된 스테레오 카메라의 Head-Eye 보정 및 Wheel 보정을 동시에 수행하는 방법을 제안한다. 카메라가 이동로봇의 고정형 기구부에 장착되어있는 경우를 고려한 기존의 방법들은 최근 일반적인 이러한 시스템에 적용될 수 없다. 이러한 문제점을 해결하기 위하여 본 논문에서는 기존 방법을 바탕으로 한 선형 반복적인 방법을 고안하였다. 이것은 동시보정을 통한 효율성뿐만 아니라 정확도 면에서도 만족할만한 결과를 얻었다. 그리고 비선형 최적화 기법을 통해 보다 높은 정확도의 보정을 구현했다.

렌즈왜곡효과를 보상하는 새로운 Hand-eye 보정기법 (A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect)

  • 정회범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.596-601
    • /
    • 2000
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

  • PDF

로보트 성능측정 및 Calibration 시스템 (Robot performance test and calibration systme)

  • 김문상;유형석;장현상;허재범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.596-601
    • /
    • 1990
  • When using robot manipulator to carry out autonomous tasks, the positioning accuracy of the robot manipulator relative to a reference coordinate frame is of greate importance. The task program, which is generated by off-line CAD-system and used in actual robot positioning, may cause serious amount of the absolute positioning error of the robot manipulator. In this study, a robot performance test and calibration algorithms are proposed in order to improve the absolute positioning accuracy of the robot end effector. Experiments were also carried out by utilizing the HYUNDAI Robot AE 7601 and KIM2-Tester, a three dimensional measurement system, which is developed in Robotics & Fluid Power Control Lab. at Korea Institute of Science and Technology.

  • PDF

신경회로망을 이용한 산업용 로봇의 역보정에 관한연구 (A Study on the Inverse Calibration of Industrial Robot Using Neural Networks)

  • 서운학
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.108-115
    • /
    • 1999
  • This paper proposes the robot inverse calibration method using a neural networks. A highorder networks called Pi-Sigma networks has been used. The Pi-Sigma networks uses linear summing units in the hidden layer and product unit in output layer. The inverse calibration model which compensates the difference of joint variables only between measuring value and analytic value about the desired pose(position orientation) of a robot is proposed. The compensated values are determined by using the weights obtained from the learning process of the neural networks previously. To prove the reasonableness the SCARA type direct drive robot(4-DOF) and anthropomorphic robot(6-DOF) are simulated. It shows that the proposed calibration method can reduce the errors of the joint variables from $\pm$3 to $\pm$0.1.

  • PDF

3차원 로봇 레이저 스캐닝 시스템의 모델링과 캘리브레이션 (Modeling and Calibration of a 3D Robot Laser Scanning System)

  • 이종광;윤지섭;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제11권1호
    • /
    • pp.34-40
    • /
    • 2005
  • In this paper, we describe the modeling for the 3D robot laser scanning system consisting of a laser stripe projector, camera, and 5-DOF robot and propose its calibration method. Nonlinear radial distortion in the camera model is considered for improving the calibration accuracy. The 3D range data is calculated using the optical triangulation principle which uses the geometrical relationship between the camera and the laser stripe plane. For optimal estimation of the system model parameters, real-coded genetic algorithm is applied in the calibration process. Experimental results show that the constructed system is able to measure the 3D position within about 1mm error. The proposed scheme could be applied to the kinematically dissimilar robot system without losing the generality and has a potential for recognition for the unknown environment.

레이저 슬릿광을 이용한 3차원 계측 장치에 관한 연구 (A Study for the 3-Dimensional Measurement System using Laser Slit-Ray)

  • 김선일;정재문;양윤모
    • 전자공학회논문지B
    • /
    • 제29B권2호
    • /
    • pp.27-39
    • /
    • 1992
  • 3 Dimensional measurement system using camera and laser slit-ray is studied. Precise calibration technique in this system is suggested. Calibration is accomplished with calibration die, calibration block and robot. For obtaining calibration parameters, the equations are solved using least square error method from a great many calibration points to reduce measuring error. Continuous measurement is possible for the object which is larger than one frame of camera. The efficiency and usability are proved by applying to the tire profile measuring system which measures tire profile using robot and this system.

  • PDF

Off-line programming sysytem을 위한 로보트운동계의 calibration (Calibration of robot kinematics for the off-line programming system)

  • 김문상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.511-517
    • /
    • 1988
  • Movement order program of robot operating program is generally made by teach-in method. Therefore in most cases it is sufficient as long as the robot system shows a reguired repeatability for the working conditions. But the trend in the robot application moves to the automatic generation of the working programs. A mathematical robot model similar to the reality is necessary for the analysis of the kinematic transformation of the robot system. The purposes of this paper are to make a better describing form and to suggest an automatic algorithm for kinematic parameter identification.

  • PDF