• 제목/요약/키워드: Robot's hand

검색결과 110건 처리시간 0.028초

로보트 기구학을 이용한 3차원 등편의 작업영역의 생성 (Generation of 3-dimensional isocomfort workspace using the robot kinematics)

  • 기도형
    • 대한인간공학회지
    • /
    • 제16권3호
    • /
    • pp.11-21
    • /
    • 1997
  • The purpose of this study is to obtain 3-dimensional isocomfort workspace using the robot kinematics, which is based on perceived discomfort in varying postures for manipulating four types of controls. Fifteen healthy male subjects participated in the experiment where their perceived discomfort in the given postures was measured, in which L32 orthogonal array was adopted. The shoulder flexion and adduction-abduction, elbow flexion, types of controls, and right/left hands were selected as experimental variables. The results showed that the shoulder flexion and adduction-abduction, elbow flexion, and types of controls significantly affected the perceived discomfort at .alpha. =0.01. Depending upon the types of control used, regression equations predicting perceived dis- comfort and three dimensional isocomfort workspace were suggested based on the experiemntal cata. Using the equations, driver's isocomfort workspace in his/her cabin for pushing operation was illustrated, in which the robot kinematics was employed to describe the translational relationships between the upper arm and the lower arm/hand. It was ecpected that isocomfort workspace could be used as a valuable guideline to design workplaces ergonomically.

  • PDF

대중량물 취급용 로봇을 위한 전기-공압구동기를 사용한 복합구동 방식의 개발 (Development of a control method using both electric and pneumatic actuators for a heavy load handing robot)

  • Park, S.D.;Jeong, K.W.;Youm, Y.I.
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.14-21
    • /
    • 1993
  • Pneumatic actuators have greater power to weight ratio than electric ones, but they have been rarely used as robotic actuators because of poor accuracy resulted from nonliearity of air. On the other hand, electric servo motors have glld controllability, but they have poor power to weight ratio. For the heavy load handling robot a combined actuating method was developed for vertical and horizontal axes of RISTBOT-ll which handles up to 250kgf load. In this paper, the control method is implemented and analyzed for the manufactured heavy load handling robot.

  • PDF

PUMA형 로보트 머니플레이터의 강인한 위치/힘 혼합제어 (Robust Hybrid Position/Force Control of a PUMA-Like Robot Manipulator)

  • 박재욱;이건복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.575-578
    • /
    • 1995
  • In general, the control of robot manipulator is classified into position control and force control. Position controllers give adequate performance when a manipulator is following a trajectory through space and end-effector has no contact with environment. However for most tasks performed by robot manipulator in industry, contact is made between the end-effector and manipulator's environment, so position control may not suffice. The objective of this study is to control both position of a manipulator and the contact forces generated at the hand by using a conceptually simple control law. Position and force control problem is decoupled into subtasts via taskspace formulation and inverse dynamics. Then, the position controllers are designed for the task space variable which represent tangent motion and the forte controllers are designed for the lash space variables which represent normal force.

  • PDF

뇌졸중 환자의 손 고정장치 제어를 위한 다축 힘/모멘트센서 개발 (Development of Multi-Axis Force/Moment Sensor for Stroke Patient's Hand Fixing System Control)

  • 김현민;윤정원;김갑순
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.351-356
    • /
    • 2011
  • Stroke patients should exercise for the rehabilitation of their fingers, because they can't use their hand and fingers. Their hand and fingers are fixed on the hand fixing system for rehabilitation exercise of them. But the hands clenched the fist of stroke patients are difficult to fix on it. In order to fix the hands and fingers, their palms are pressed with pressing bars and are controlled by reference force. The fixing system must have a five-axis force/moment sensor to force control. In this paper, the five-axis force/moment sensor was developed for the hand fixing system of finger-rehabilitation exercising system. The structure of the five-axis force/moment sensor was modeled, and designed using finite element method(FEM). And it was fabricated with strain-gages, then, its characteristic test was carried out. As a result, the maximum interference error is less than 2.43 %.

공공서비스 로봇의 의인화에 관한 사용자 선호 (User Preference for the Personification of Public Service Robot)

  • 김반석;김승인
    • 디지털융복합연구
    • /
    • 제18권2호
    • /
    • pp.361-366
    • /
    • 2020
  • 본 연구는 사람들의 선호를 조사하여 공공서비스 로봇에 의인화가 어떻게 적용돼야 할지 알아보는 연구이다. 공공장소에서 서비스를 제공하는 공공서비스 로봇이 도입되고 있으며 이는 앞으로도 증가할 전망이다. 적절하게 의인화된 로봇은 사용자 경험을 증진하는 효과가 있지만 지나치게 인간과 흡사한 로봇은 불쾌감을 느끼게 한다. 이에 따라 공공서비스 로봇에 요구되는 의인화 적용 기준을 마련하는 것이 필요하다. 이를 위해 설문조사와 심층 인터뷰를 진행하였다. 분석 결과 사람들은 로봇에 언어적 상호작용을 선호하며 음성의 적절한 나이는 20~30대이다. 로봇에 생체 신호는 나타나지 않는 것이 바람직하며 개인에 맞춤화된 서비스에 대한 요구가 있다는 것을 알게 되었다. 본 연구를 통해 사용자 경험을 높이는 공공서비스 로봇 디자인에 기여할 것으로 기대한다.

The influences of sex on the human emotions toward robots

  • Ben-Lamine, Mohamed-Sahbi;Shibata, Satoru;Kanya, Tanaka;Shimizu, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.191-194
    • /
    • 1995
  • This paper evaluates the influences of sex on the human emotions while coexisting with robots. When we consider human vision, robot's motion is the most important parameter which influences human emotions and must be well controlled for males and females emotions. On the other hand, when we consider human touch of sense, which is effective for cooperation transmitting mutual forces, the softness of robot is an important parameter for human emotions and must be also well controlled for males and females emotions. From these points of view, at first, we evaluate robot's motion under four different shapes of velocity pattern while handing over a cup to humans. Second, we evaluate robot's softness realized by impedance control. From the first experiment, we concluded that the conditions of choosing an adequate maximum velocity value and locating the velocity peak at the center or the first half of the duration are necessary for male's emotions. In addition, the smooth velocity decrease in the last part of the velocity pattern's duration is desired for female's emotions. From the second experiment, we concluded that females prefer lighter values of virtual impedance characteristics than males and any small increase on the heaviness of virtual impedance values is followed by the negative exponential change on human emotions.

  • PDF

복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구 (Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument)

  • 김지언;이민철;이태경;최승욱;박민규
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

이동 로봇의 장애물회피를 위한 퍼지제어기와 실시간 제어시스템 적용을 위한 저(低)복잡도 검색테이블 공유기법 (A Fuzzy Controller for Obstacle Avoidance Robots and Lower Complexity Lookup-Table Sharing Method Applicable to Real-time Control Systems)

  • 김진욱;김윤구;안진웅
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.60-69
    • /
    • 2010
  • Lookup-Table (LUT) based fuzzy controller for obstacle avoidance enhances operations faster in multiple obstacles environment. An LUT based fuzzy controller with Positive/Negative (P/N) fuzzy rule base consisting of 18 rules was introduced in our paper$^1$ and this paper shows a 50-rule P/N fuzzy controller for enhancing performance in obstacle avoidance. As a rule, the more rules are necessary, the more buffers are required. This paper suggests LUT sharing method in order to reduce LUT buffer size without significant degradation of performance. The LUT sharing method makes buffer size independent of the whole fuzzy system's complexity. Simulation using MSRDS(MicroSoft Robotics Developer Studio) evaluates the proposed method, and in order to investigate its performance, experiments are carried out to Pioneer P3-DX in the LabVIEW environment. The simulation and experiments show little difference between the fully valued LUT-based method and the LUT sharing method in operation times. On the other hand, LUT sharing method reduced its buffer size by about 95% of full valued LUT-based design.

5절링크와 짐벌기구로 구성된 병렬형 6자유도 햅틱 핸드컨트롤러의 설계 (Design of a 6-DOF Parallel Haptic Rand Controller Consisting of 5-Bar Linkages and Gimbal Mechanisms)

  • 류동석;손원선;송재복
    • 대한기계학회논문집A
    • /
    • 제27권1호
    • /
    • pp.18-25
    • /
    • 2003
  • A haptic hand controller (HHC) operated by the user’s hand can receive information on position and orientation of the hand and display force and moment generated in the virtual environment to the hand. In this paper, a 3-DOF hand controller is first presented, in which all the actuators are mounted on the fixed base by combining a 5-bar linkage and a gimbal mechanism. The 6-DOF HHC is then designed by connecting these two 3-DOF devices through a handle which consists of a screw and nut. Analysis using performance index is carried out to determine the dimensions of the device. The HHC control system consists of the high-level controller for kinematic and static analysis and the low-level controller for position sensing and motor control. The HHC used as a user interface to control the mobile robot in the virtual environment is given as a simple application.

BCI 기반 로봇 손 제어를 위한 악력 변화에 따른 EEG 분석 (EEG Analysis Following Change in Hand Grip Force Level for BCI Based Robot Arm Force Control)

  • 김동은;이태주;박승민;고광은;심귀보
    • 한국지능시스템학회논문지
    • /
    • 제23권2호
    • /
    • pp.172-177
    • /
    • 2013
  • BCI (Brain Computer Interface)는 인간의 뇌에서 측정된 EEG (Electroencephalogram)를 활용하여 의수와 같은 기기를 조종할 수 있는 좋은 방법 중 하나이다. 본 논문에서는 EEG와 힘과의 관계를 알아보고자 최대수축악력 (MVC)의 25%, 50%, 75%로 3개의 등급으로 나누어 EEG 변화를 측정하였다. 얻어진 EEG data를 FFT와 power spectrum analysis로 ${\alpha}$, ${\beta}$, ${\gamma}$파로 나누어 각 파형의 파워 값을 구한 뒤, 구해진 EEG 파워 값을 PCA와 LDA를 사용하여 특징 추출 및 분류를 하였다. 실험 결과 25%의 악력을 가할 때 보다 75%의 악력 때 더 높은 EEG 파워의 증가를 확인하였고, 왼손과 오른손은 각각 52.03%와 77.7%의 분류율을 나타내었다.