• Title/Summary/Keyword: Road-effect zone

Search Result 57, Processing Time 0.022 seconds

Computational Flow Analysis on Wind Profile Change Projected to a Wind Turbine Behind Saemangeum Seawall (새만금 방조제에 의한 풍력터빈 입사풍 변화의 전산유동해석)

  • Woo, Sang-Woo;Kim, Hyun-Goo
    • New & Renewable Energy
    • /
    • v.9 no.1
    • /
    • pp.6-11
    • /
    • 2013
  • Jeollabuk-do has announced a future plan for the Saemangeum Wind Farm which includes the installation of fourteen wind turbines in a single line, located 500m back from the Saemangeum Seawall. It is anticipated as a positive effect that, for sea breeze blowing toward land, the average wind speed could be accelerated and the wind speed distribution could be uniformized by dint of the seawall, an upstream structure of the turbines. At the same time it is also anticipated as a negative effect that the strength of wind turbulence could be increased due to the flow separation generated at the back end of the seawall. According to the results of the computational fluid dynamics analysis of this paper, it has been observed that, at the 50m zone on the road surface located at the uppermost part of the Saemangeum Seawall, the average wind speed has been accelerated by approximately 6~7% and that wind shear has been decreased by 70%, but this positive effect disappears in the zone situated beyond the 100m from the back end of the seawall. It has also been observed that flow separation exists to a limited extent only below the bottom of the blade-sweeping circle and, furthermore, does not extend very far downstream of the wind. As a conclusion, it can be said that the seawall neither positively nor negatively affects the proposed Saemangeum Seawall Wind Farm layout.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.

A study on the development of muti-media system for road guideline (길안내를 위한 멀티미디어 개발에 관한 연구)

  • Jung Ho-Young;Lee In-Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.97-107
    • /
    • 2004
  • As one of the most serious urban problems, routine city traffic congestion causes not only unpleasantness but also damage with increases of road tolls. Recently, many TDM plans are being improved along with plans to more effectively utilize established facilities and maximize the effect. To achieve the purpose of Intelligent Transport Systems(ITS). Recently, the core of ITS is Advanced Traveler information Systems (ATIS.) that are activity researched. A development of various muti-media system is very important of road guideline. First of all a business processing for offering travel information and give a consideration to the United states of various muti-media systems.

  • PDF

Comparative Study of Truck Traffic System Management for Reducing Air Pollution Impact - Forcusing on Sihwa National Industrail Complex, Siheung City - (교통체계개선에 의한 화물교통 대기오염영향 저감방안 - 시흥시 시화국가산업단지를 중심으로 -)

  • Lee, Hee-Kwan;Kim, Hyung-Chul;Kwon, Woo-Taeg
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2006
  • The factor of air pollution in a large industrial city is not only manufactories but also, activities related to trucks. Sihwa National Industrial Complex is located in Siheung City; due to the industries, more diverse activities related to trucks occur in Siheung City than other cities. In particular, the new residential area in Siheung City is close to the industrial complex; so, the damage of this residential area is expected that it would be more serious and vulnerable than other areas. The aim of this study is to analyze influence of the air pollution by a truck in Siheung City. ISCST3 Model and Arc View program were used for this study and Siheung City was divided into 1,000 meter by 1,000 meter grid to analyze. Furthermore, this study suggested two reduction controls of air pollution in Siheung City, and analyzed the results from these reduction managements. The results of the present condition showed that residences located in north of Sihwa Industrial Complex are influenced by air pollution material. Furthermore, air pollution by trucks has affected on the residents which is near the road in Siheung City. Therefore, this study suggested two reduction controls by the Traffic System Management. The first alternative plan is setting the truck traffic limitation zone in the road that is located in south of resident areas and many trucks traffic. Next, the second alternative plan is setting freight truck way on the most traffic road to enter the industrial complex. The reduction effect of the first alternative is good on the residential area. And, the second alternate about freight truck way is divided passenger cars into trucks. Therefore, there are increase of average speed and decrease of average concentration, and spatial reduction effects found in wide areas.

Research on the relationship between the thermal characteristics and the type of land cover in Beijing urban area by ASTER data

  • Zhu, QiJiang;Zhang, Xin;Bai, Xianghua
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.277-279
    • /
    • 2003
  • The study utilizes remote sensing as the main monitoring means. With different spatial high-resolution, multichannel ASTER remote sensing image as the main information in Beijing city zone; with regional border and statistical data as auxiliary factor a study between the thermal space distribution character and the underground medium is analyzed based on the GIS logical algorithm and synthetic analysis technology. Results show thermal forming mechanism and the rule of distribution is mainly related to the underground medium and the change of the city distribution. Different underground medium has different degree and intensity influence on the thermal space distribution. Furthermore, urban greenbelt and water areas can reduce the thermal effect and large-scale greenbelt creates green island effect. In addition, Road net, residential area, population density, heat resources and so on have some positive effect on the thermal distribution, which increase the local temperature and intensity on the other hand. It is important to study the thermal distribution and its related factors, which contributes to the plan, construction and development of the city.

  • PDF

Applications of Improved Low-Flow Mortar Type Grouting Method for Road Safety and Constructability in Dangerous Steep Slopes (급경사지 붕괴 위험지역의 도로 안전 및 시공성을 고려한 개선된 저유동 몰탈형 그라우팅공법 적용성 분석)

  • Choi, Gisung;Kim, Seokhyun;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.409-415
    • /
    • 2020
  • Low-flow mortar injection method grouting technology was selected and the traffic area was preserved as much as possible in order to secure safety for road traffic when the outflow and subsidence of landfill occurred due to ground-water, and etc. In particular, the current existing method was newly improved since there are risks of damage such as hydraulic fracturing at the lower part of the road, spilling of soil particles on steep slopes, and bumps on the road due to excessive injection pressure during construction. This study was carried out at the site of reinforcement work on the road as a maintenance work for the danger zone for collapse of the steep slope of the 00 hill, which was ordered from the 00 city 00 province. The improved low-flow mortar type grouting method adopted a new automated grouting management system and especially, it composites the method for grouting conditions decision by high-pressure pre-grouting test and injection technology by AGS-controlled and studied about grouting effect analysis by using new technology. By applying the improved low-flow mortar type grouting method, it was possible to lay the groundwork for road maintenance work such as the prevention of subsidence of old roads, uneven subsidence of buildings and civil engineering structures, and of soil leakage of ground-water spills. Furthermore, the possibility of application on future grouting work not only for just construction that prevents subsidence of old roads but also for various buildings and civil engineering structures such as railroads, subways, bridges, underground structures, and boulder stone and limestone areas was confirmed.

Analysis of the Characteristics of Road and Transportation Safety Facilities Affecting Pedestrian Traffic Accidents around School Zones: Using Spatial Poisson Model (어린이보호구역 내 도로 및 교통안전시설이 보행자 교통사고에 미치는 영향 분석: 공간포아송모형을 이용하여)

  • Ko, Dong-Won;Park, Seung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.11
    • /
    • pp.213-223
    • /
    • 2021
  • It is very important to build a safe walking environment for children because children are more likely to be exposed to traffic accidents than adults due to their behavioral and physical characteristics. Therefore, this study analyzed the characteristics of road and transportation safety facilities that affect pedestrian traffic accidents around school zones using spatial poisson regression. The pedestrian-vehicle crash data in Seoul 2016-2018 was provided by the Traffic Accident Analysis System(TAAS). The main analysis results are as follow; First, the more intersections and the higher percentage of neighborhood roads in the school zone, the higher the risk of pedestrian traffic accidents. Second, the pedestrian push button was found to reduce the occurrence of pedestrian traffic accidents. Third, except for the pedestrian push button, none of the transportation safety facilities considered in this study were effective in reducing the risk of pedestrian traffic accidents. On the other hand, if not only the improvement of physical facilities but also non-physical factors such traffic safety education are supported, the effect for reducing traffic pedestrian traffic accidents in the school zone is expected to be further maximized.

Finite Element Analysis for Fracture Resistance of Fiber-reinforced Asphalt Concrete (유한요소해석을 통한 섬유보강 아스팔트의 파괴거동특성 분석)

  • Baek, Jongeun;Yoo, Pyeong Jun
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • PURPOSES : In this study, a fracture-based finite element (FE) model is proposed to evaluate the fracture behavior of fiber-reinforced asphalt (FRA) concrete under various interface conditions. METHODS : A fracture-based FE model was developed to simulate a double-edge notched tension (DENT) test. A cohesive zone model (CZM) and linear viscoelastic model were implemented to model the fracture behavior and viscous behavior of the FRA concrete, respectively. Three models were developed to characterize the behavior of interfacial bonding between the fiber reinforcement and surrounding materials. In the first model, the fracture property of the asphalt concrete was modified to study the effect of fiber reinforcement. In the second model, spring elements were used to simulated the fiber reinforcement. In the third method, bar and spring elements, based on a nonlinear bond-slip model, were used to simulate the fiber reinforcement and interfacial bonding conditions. The performance of the FRA in resisting crack development under various interfacial conditions was evaluated. RESULTS : The elastic modulus of the fibers was not sensitive to the behavior of the FRA in the DENT test before crack initiation. After crack development, the fracture resistance of the FRA was found to have enhanced considerably as the elastic modulus of the fibers increased from 450 MPa to 900 MPa. When the adhesion between the fibers and asphalt concrete was sufficiently high, the fiber reinforcement was effective. It means that the interfacial bonding conditions affect the fracture resistance of the FRA significantly. CONCLUSIONS : The bar/spring element models were more effective in representing the local behavior of the fibers and interfacial bonding than the fracture energy approach. The reinforcement effect is more significant after crack initiation, as the fibers can be pulled out sufficiently. Both the elastic modulus of the fiber reinforcement and the interfacial bonding were significant in controlling crack development in the FRA.

Numerical sensitivity analysis for the reinforcement effect of a curvature of a tunnel floor on soft grounds (연약지반에 위치한 터널 바닥부 곡률의 보강효과에 대한 수치해석적 민감도 분석)

  • You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.2
    • /
    • pp.61-76
    • /
    • 2021
  • As the number of existing road tunnels increases every year, collapse and floor heaving accidents occur frequently during construction. The collapse among tunnel accidents dominates, so that studies related to the floor heaving are relatively insufficient. Accordingly, many studies to reinforce the lower part of the tunnel have been conducted, but the analysis on the effect of the curvature of the tunnel floor is insufficient. Therefore, in this study, the effects of the upper analysis area height and the coefficient of lateral earth pressure of the tunnel located on a tuff deterioration zone with a large rock cover, as well as the floor curvature, were examined through sensitivity analysis. As a result of the analysis, it turned out that the overall stability of the tunnel increases as the floor curvature increases, the coefficient of lateral earth pressure decreases, and the upper analysis region increases.

Distribution Model of the Wintering Red-crowned Crane and White-naped Crane in Cheorwon, Korea (철원지역에서 월동하는 두루미와 재두루미의 서식밀도모델)

  • Yoo, Seung-Hwa;Lee, Ki-Sup;Kim, Hwa-Jung;Hur, Wee-Haeng;Kim, Jin-Han;Park, Chong-Hwa
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.4
    • /
    • pp.282-291
    • /
    • 2014
  • This study was conducted to make distribution model of the Red-crowned Crane and the White-naped Crane according to the anthropogenic and natural factors affecting distribution of crane in Cheorwon, Korea. It was investigated that the impact power and its range of the indirect anthropogenic influence to feeding flock density in cranes from the road, residential area, military facilities, civilian control zone (CCZ), greenhouse and natural influence such as roosting site and available feeding area. Available feeding area is the most important factor for the crane's feeding site selection. The feeding flock density of the cranes near the residential area was lower than that of area far from the area, and tended to increase within 2.5 km distance. The increasing tendencies of feeding flock density from military facilities and high traffic volume road were similar, but the density in military facilities increased within 800 m, and the density from high traffic volume road increased within 2 km. These results suggested that residential area, military facilities and the road with high traffic volume had significant effect on foraging densities to the certain range. As the distance from the road with low traffic volume and roosting site increased, feeding flock density tended to decrease. The density of Red-crowned crane and White-naped crane inside the CCZ were respectively higher than those of outside the CCZ, especially for the Red-crowned crane. As a result, density of Red crowned cranes inside the CCZ was 5.2 times higher than that of outside, while that of white-naped cranes was 2.2 times bigger. If the density of greenhouse is lower than $40km^{-2}$, crane's feeding flock density in the low greenhouses density area was higher than that of high greenhouses density area. However, there was no difference in the feeding flock density if the density of the green houses is higher than $40km^{-2}$. The model for the Red-crowned Crane was related with available feeding area, distance from residential area, civilian control zone and distance from high traffic road. The model of the White-naped Crane was related with available feeding area, distance from roosting site and distance from lake. Finally, the estimated feeding flock density of cranes significantly correlated with density model according to the natural and anthropogenic factors.