• 제목/요약/키워드: River assessment

검색결과 1,020건 처리시간 0.027초

북한강 수계 호소퇴적물 오염도 평가 (Pollution Assessment of Sediment in Lakes of Buk-han River Basin)

  • 이보미;성기선;김국회;문권영;신명철;홍정기;김갑순;유순주;허인애;노혜란
    • 한국물환경학회지
    • /
    • 제35권2호
    • /
    • pp.105-114
    • /
    • 2019
  • The objective of this study was to investigate the pollution assessment of organic matters, nutrients, and metals in sediment in major lakes (5 lakes and 17 sites) of Buk-han river using various sediment pollution assessment guidelines and indices. The concentrations of organic matters and nutrients were lower than class IV (Sediment pollution assessment guidelines of Korea) and Severe Effect Level (SEL, Sediment pollution assessment guidelines of Ontario). This results indicated that the lakes sediments were unpolluted and tolerable level for sediment dwelling organisms by organic matters and nutrients. However, several sites of Chuncheon and Soyang lakes were evaluated "heavily polluted" level by organic index (Org-index). The order of lakes by metals concentrations from the one with the highest concentration was Hwacheon, Chuncheon, Cheongpyeong, Uiam, Soyang. All lakes except Hwacheon were assessed unpolluted to marginally and tolerable level for sediment dwelling organisms by metals based on sediment pollution assessment guidelines (Korean and Ontario), indices of geoaccumulation ($I_{geo}$), pollution loading (PLI) and ecological risk (RI). In Lake Hwacheon, every investigated sites were polluted with metals, especially Hg, based on sediment pollution assessment guideline of Korea and indices ($I_{geo}$, PLI and RI). The dwelling organisms in sediment of Hwacheon Lake were likely to be severed by metals.

Estimation of River Pollution Index Using Landsat Imagery over Tamsui River, Taiwan

  • Wang, Ying Hsuan;Sohn, Hong-Gyoo
    • Ecology and Resilient Infrastructure
    • /
    • 제5권2호
    • /
    • pp.88-93
    • /
    • 2018
  • In-situ water quality sampling is used for accurate water quality assessment. However, in-situ water quality sampling offers limited samples and requires much time and intensive labors. Remote sensing approach has recently applied for water quality assessment. It has shown the advantage of offering a synoptic view but also more efficient and economical. In this study, we utilized Landsat Imagery to estimate the water quality of the Tamsui River basin, considered as one of the most important rivers located in the north of Taiwan. In order to monitor water quality of Tamsui River basin, a linear regression relation between the value of spectral radiance and four water quality parameters are investigated with 38 water sampling stations. Through the regression model, we could estimate river pollution index (RPI) from the predicted value of four water quality parameters. By using RPI, we can examine the pollution level of Tamsui River. The accuracy of RPI conversion of this study ranged from 32.2% to 68.2%.

SWAT 모형과 TOPSIS 기법을 이용한 우리나라 물이용 취약성 평가 (Parameteric Assessment of Water Use Vulnerability of South Korea using SWAT model and TOPSIS)

  • 원광재;성장현;정은성
    • 한국수자원학회논문집
    • /
    • 제48권8호
    • /
    • pp.647-657
    • /
    • 2015
  • 본 연구는 국내 12개수계인 한강, 안성천, 금강, 삽교천, 영산강, 섬진강, 탐진강, 만경강, 동진강, 낙동강, 태화강, 형산강 유역에 대한 물이용 취약성 평가를 실시하였다. SWAT(Soil and Water Assessment Tool) 모형을 이용하여 국내 12개 수계의 연유출량을 도출하였고, 각 유역별 면적 및 인구당 유출량을 비교하였다. 취약성 평가를 위해 18개 지표로 구성하였고, 물이용의 수요, 손실 및 공급의 측면으로 구분하였다. 이때의 가중치는 객관적 가중치의 적용을 위해 엔트로피(Entropy)방법을 사용하였고 정량적인 물이용 취약성 평가를 위해 다기준 의사결정기법 중 하나인 TOPSIS(Technique for Order of Preference by Similarity to Ideal Solution) 기법을 적용하였다. 그 결과, 형산강의 물이용이 가장 취약하였고, 삽교천, 동진강, 섬진강, 안성천, 만경강, 낙동강, 탐진강, 영산강, 금강, 태화강, 한강 순이었다. 본 연구 결과는 향후 기후변화 취약성 평가를 위한 지표 개발에 이용할 수 있겠다.

수질 영향평가 신뢰수준 향상을 위한 낙동강 유역 미관측 지점에서의 일사량 추정: 수정형 Angstrom모형과 투과율모형의 비교 (Estimation of Daily Solar Radiation at the Missing Point for Water Quality Impact Assessment in Nakdong River Watershed: Comparison of Modified Angstrom Model and Transmittance interpolation Model)

  • 이길하
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.219-227
    • /
    • 2012
  • Daily solar radiation is essential for water resources planning and environmental impact assessment. However, radiation data is not commonly available in Korea other than in big cities, and there has been no direct measurement for rural areas where water resources planning and environmental impact assessment is usually most needed. In general, missing radiation data is estimated from nearby regional stations within a certain distance, and this study compared two dominant methods (modified Angstrom equation and transmittance interpolation method) at six stations in Nakdong River watershed area. Two methods shows a similar level of accuracy but the transmittance interpolation method is likely to be superior in that there is no need for any measurement element since the modified Angstrom equation require the sunshine hour measurement. This study will contribute to improve water resource and water quality management in Nakdong River watershed.

낙동강 하구둑 건설 전·후의 기상환경 변화 특성 (Characteristics of Meteorological Environment Variation Before and After Construction of Nak-dong River Estuary Barrage)

  • 전병일
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.135-145
    • /
    • 2005
  • This study was conducted to investigate the characteristics of meteorological environment variation before and after construction of Nak-dong river estuary barrage. We used meteorological data(air temperature, precipitation, relative humidity, visibility, wind) at Gimhae airport meteorological station. The construction of river estuary barrage can change climate at the neighboring districts and influence human's health and vegetable. The construction of Nakdong river estuary barrage brought rise of temperature, decrease of relative humidity and increase of poor visibility frequency.

홍천강 유역에 서식하는 멸종위기종 수달의 개체군변이분석을 통한 생태모니터링 연구 (Long-term population monitoring with population viability analysis of river otter in Korea)

  • 이상돈
    • 환경영향평가
    • /
    • 제22권5호
    • /
    • pp.525-528
    • /
    • 2013
  • River otter(Lutra lutra) are listed as endangered species and Natural monument in Korea, and this study examined the possibility of extinct of river otter in Hongchon river using with the application of Population Viability Analysis (PVA) technique. In Hongchon river areas population was estimated 9 individuals for the last 1999-2005 years and PVA analysis was done for the next 10 years using the average population of 9. Using the initial population the river otter was estimated 30% of extinct for the next 10 years. This estimation was quite low considering water pollution and construction of highways. Also PVA only used population size lacking in other life history information. Nonetheless river otter population can be in risk of extinction if the current construction of crossovers, cement bank are maintained. Long term information regarding life history needs essential.

친환경 소하천의 수리적 안정성 분석에 관한 연구 (A Study on Hydraulic Stable Analysis of The Natural Small River)

  • 김태경;이경훈;선병진;최천호
    • 환경영향평가
    • /
    • 제16권3호
    • /
    • pp.187-194
    • /
    • 2007
  • It started road constructions around river in 1990s. These maintenances concentrate on city river. Because river lives no living things and men don't come near there. But in spite of these river environment go to rack, river maintenances still keep on using preexistence method since 1990s. Only a part of city river environment maintenances consider environmental ability of passive river, river maintenance of a purpose of flood control still don't consider in the concrete. Because propulsion device that consider environment ability of passive river and possible application techniques don't complete. In accordance, A natural river maintenance needs absolutly a series of river projects. Because a natural river maintenance prevents a damage of environment ability. This study is to assume the flood really happened and to carry out the flood damage simulation needed in overflow simulation about the inundated zone. Also, This study examine unstable part about the hydraulic characteristic as velocities, stream power, shear, hydraulic depth, flow area in basin. And this study applied the HEC-RAS(river analysis system) model to predict flood overflow in youngsan river basin. Project flood is used the return period 100 year and inputed data that was calculated in intensity figures of illumination.

Landsat TM 영상자료를 이용한 대청호의 영양상태 평가 (Assessment of Trophic State for Daecheong reservoir Using Landsat TM Imagery Data)

  • 한의정;김태근;정동환;천세억;김신조;유순주;황종연;김태승;김명희
    • 환경영향평가
    • /
    • 제7권1호
    • /
    • pp.81-91
    • /
    • 1998
  • The objective of this study was to use remotely sensed data, combined with in situ data, for the assessment of trophic state for Daecheong reservoir. Three Landsat TM(Thematic Mapper) imagery data were processed to portray trophic state conditions. The remotely sensed data and the measured data were obtained on 20 June 1995. Regression models have been developed between the chlorophyll-a concentration and reflectance which was converted to Landsat TM digital data. The regression model was determined based on the correlation coefficient which was higher than 0.7 and was applied to the entire study area to generate a distribution map of chlorophyll-a and trophic state. The equation, providing estimates of chlorophyll-a concentration, represented the year-to-year spatial variation of trophic zones in the reservoir. Satellite remote sensing data derived from Landsat TM had been successfully used for trophic slate mapping in Daecheong reservoir.

  • PDF

하천수 열원 열펌프 시스템의 성능 특성 및 경제성 평가 (Performance Characteristics and Economic Assessment of a River Water: Source Heat Pump System)

  • 박차식;정태훈;박홍희;김용찬
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.621-628
    • /
    • 2009
  • The objectives of this study are to analyze the performance of a river water-source heat pump and to carry out economic assessment for the heat pump. The COP of the river water-source heat pump was 3-21% higher than that of the air-source heat pump because river water provides stable operating temperature compared with air temperature throughout the year. The economic analysis was carried out by comparing the initial and operating cost of the river water-source heat pump with those of the conventional air-source heat pump. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.5 years when the capacity of the river water-source heat pump was larger than 10 RT.

열원에 따른 열펌프의 성능 비교 및 경제성 평가 (Performance Characteristics and Economic Assessment of Heat Pump Systems with the Various Heat Source)

  • 박차식;박경우;권오경
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2011
  • The objectives of this study are to analyze the performance of a heat pump system with the various heat source and to carry out economic assessment for the heat pump system. The COP of the river water and ground source heat pump system was 20% higher than that of the air source heat pump system because river water and geothermal provide stable operating temperature compared with air temperature throughout the year. In addition, the economic assessment of a heat pump system using air, river water, and geothermal as a heat source was carried out. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.3 and 4.5 years, respectively when the capacity of the river water and ground source heat pump was larger than 10 RT.