Watershed Management Plan through Water Quality Monitoring for Main Branches of 4 Water Systems in Chungcheongnamdo (충청남도 4대수계 주요 지류하천 수질 모니터링을 통한 유역 관리 방안)

  • Park, Sanghyun;Kim, Hongsu;Cho, Byunguk;Moon, Eunho;Choi, Jinha
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.2
    • /
    • pp.163-172
    • /
    • 2016
  • This study aimed to develop a plan for effective performance of a watershed through correct identification of a river watershed by using the flowrate of the river and water quality data, which is the basis for the establishment of the water environment policy. The target river for water quality improvement was selected based on the monitoring result for 4 water systems in Chungcheongnamdo province in the recent 3 years. The result of analysis for the distribution of discharge capacity by a pollution source group for the water quality improvement target river showed that most of the target river has a high discharge capacity in the water system for living and livestock. Analysis for the density of the total discharge capacity of the whole watershed of Chungcheongnamdo indicated that the river that needs water quality improvement has high BOD concentration and high discharge load density at the point that this river is located. Thus, for efficient watershed management through selection and concentration, Chungcheongnamdo needs to improve the target river in priority. Stepwise planning is also required to establish and execute the water quality improvement in order to satisfy said target water quality, and establish the index for the water improvement rate for its evaluation.

WATER RESOURCES POLICY AND CONFLICT RESOLUTION IN SOUTH KOREA : WIN-WIN STRATEGY

  • Choi, Yearn-Hong;Lee, Tae-Sam
    • Water Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.231-241
    • /
    • 2001
  • Since South Korea has uneven rainfall and deteriorating water quality, it is imperative to create a comprehensive water resources policy and management. This paper is to adopt a win-win policy for upstream-downstream local governments that have been in water rights-related disputer or conflicts in the process of allocating water and maintaining water quality. The Win-Win Policy can be an integrated river-basin approach. We define the win-win policy, introduce the win-win case of Delaware River and Colorado River in the United States, and suggest the win-win policy for Nakdong River in South Korea. Nakdong River is chosen for this paper because it has more serious problems in preserving water quantity and maintaining water quality.

  • PDF

Occurrence of Perchlorate in Drinking Water in Korea (국내 주요 정수장 수돗물의 퍼클로레이트 검출현황)

  • Kim, Hyun-koo;Kim, Joung-hwa;Lee, Youn-hee
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.822-828
    • /
    • 2007
  • Perchlorate is an unregulated contaminant but recently many cases of perchlorate contamination have been reported in the US. In Japan, also, a couple of contamination incidents caused by perchlorate occurred. Against this backdrop, investigation on perchlorate was urgent for Korea. Accordingly, perchlorate investigation in tap water and river water was conducted one time a week for seven consecutive weeks at major water sources of Korea including Han River, Guem River, Yeong-san River, and Nak-dong River. Perchlorate was not found at Han River, Guem River, and Yeong-san River. However, all the 4 tap water samples in Nak-dong River recorded high level of perchlorate. Among others, NT1 located at Daegu posted the highest value of $22.3{\mu}g/L$. This level is lower than $24.5{\mu}g/L$, the threshold recommended by US EPA. Still, perchlorate contamination in drinking water can deal a heavy blow to nerve development of infants and children by causing iodine deficiency. At the 1st and 2nd investigations, perchlorate concentration reached $18.7{\sim}95.6{\mu}g/L$ and $4.0{\sim}25.6{\mu}g/L$ respectively, both of which are relatively higher. The high perchlorate concentration in Nak-dong River was possible because of the waste water discharged from LCD manufacturing factory which was located at NS3 in Gumi, Korea. Perchlorate concentration of waste water from the factory was $730{\sim}1,858{\mu}g/L$.

Biiological Analysis of Water Quality from the Water System of Namcheon River, Kyungsan (경상남천수계의 생물학적 수질판정)

  • Suh, Younbg Hee;Sang Ock Park
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.46-53
    • /
    • 1990
  • Analyzing the water quality biologically by the biotic index ($\beta$) of Beck-Tsuda method, for four sites of the water system of Namcheon River which reaches a length of 19.5km and flows through the kyungsan-town and Namcheon-myun in Kyungsan-gun of the suburbs of Taegu and extends to the Gumho-river on the lower, the results are summarized as follows: 1) An indicator species collected from the water system of Namcheon River comprises 78 species. Among them, 27 species are intolerant species and 51 species are tolerant species to water pollution. 2) The water of 2 sites, Weondong-bridge, Sanjeon-iron bridge was clearly water, oligosaprobic zone. The water of Youngdae-bridge was slightly polluted water, $\beta$-measosaprobic zone. But the water of Maehoildong bridge was severely polluted water, polysaprobic zone. 3) The Namcheon River was mainly polluted with sewage from the kyungsan town, with industrial wastes and products from many factories surviving the town. 4) The pH wate system of Namcheon River was alkalescent. 5) The map showing a class of water quality analyzed biologically was also prepared for each site of the water system of Namcheon River, Kyungsan. 6) It is requested that a waste water disposal plant should be established near Youngdae-bridge and Maehoildong-bridge respectively.

  • PDF

Contamination Sources of Several Potentially Hazardous Compounds Found at the Gap Stream and the Miho Stream, Two Major Tributaries of the Geum River (금강 수계 주요지류인 갑천과 미호천에서 잠정유해물질 오염원 확인 연구)

  • Lee, Jun-Bae;Lee, Jay-Jung;Cho, Yoon-Hae;Yoon, Jo-Hee;Hong, Seoun-Hwa;Lee, Dae-Hee;Lee, Dae-Hee;Cho, Young-Hwan;Shin, Ho-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2016
  • BACKGROUND: Water quality is of concern to water utility operators, public health officials, and populations using the water. If any contaminant is released from a point of entry, it could be spread rapidly throughout the water stream. So the identification of the location of the points of entry and its release history are critical informations to establish the management strategy.METHODS AND RESULTS: Aniline, nonylphenol, pentachlorophenol and formaldehyde in 39 surface water samples were analysed using Gas chromatography-mass spectrometry (GC-MS) methods. Formaldehyde, aniline and nonylphenol were mainly detected in the near sites where industrial waste water and domestic sewage were discharged into stream. But pentachlorophenol was detected in the downstream samples where pulp manufacturing plants were operated.CONCLUSION: Results indicate that pentachlorophenol found in main stream of Guem river was mainly introduced from pulp manufacture industries. Otherwise, formaldehyde, aniline and nonylphenol were mainly contaminated from the industrial waste water and domestic sewage.

Spatial and seasonal variations of organic carbon level in four major rivers in Korea

  • Lee, Jaewoong;Shin, Kisik;Park, Changhee;Lee, Seunghyun;Jin, Dal Rae;Kim, Yongseok;Yu, Soonju
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.84-90
    • /
    • 2016
  • Regionally the lowest average concentration of TOC was observed with 0.66 mg/L in Nakdong river, while the highest concentration of TOC was observed with 0.91 mg/L in Yeongsan river. The average concentration of TOC for national water quality monitoring site showed that the lowest average concentration of TOC was 1.58 mg/L in Han river, while the highest concentration of TOC was 3.37 mg/L in Yeongsan river. Seasonally, the average concentration of TOC at six upstream sites showed 0.77 mg/L and 0.56 mg/L, 0.69 mg/L and 0.63 mg/L, 0.80 mg/L and 0.73 mg/L, and 1.21 mg/L and 0.68 mg/L between wet season and dry season in Han river, Nakdong river, Gem river and Yeongsan river, respectively. For the national water quality site, the average concentration of TOC between wet season and dry season was 1.70 mg/L and 1.45 mg/L in Han river, 2.01 mg/L and 1.75 mg/L in Nakdong river, 2.01 mg/L and 1.60 mg/L in Gem river, and 3.75 mg/L and 3.00 mg/L in Yeongsan river. The distribution of TOC in upstream and national water quality monitoring sites on four major rivers have been influenced by seasonal and regional characteristics in Korea.

Analysis of the Effect of Water Quality Improvement on Seomgang and South Han River by Securing the Flow during the Dry Season (갈수기 유량 확보에 따른 섬강 및 남한강 본류 갈수기 수질 개선 효과 분석)

  • Lee, Seoro;Lee, Gwanjae;Han, Jeongho;Lee, Dongjun;Kim, Jonggun;Lim, Kyoung Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.25-39
    • /
    • 2019
  • The water pollution Accident in the South Han River is increasing due to increase of pollutants inflow from small streams from rural areas and reduced flow rate. This study predicted the change of water quality in the main stream of the South Han River due to climate change through the linkage of watershed and water quality models. Also, This study analyzed the effect of water quality improvement on Seomgang and the South Han River by securing the flow during the dry season. According to the scenarios for securing the river flow during drought season, the river flow in the Seomgang is increased up to 2.19 times, and the water quality during the drought season was improved up to $BOD_5$ 20.5%, T-N 40.8%, T-P 53.4%. Also, the water quality of the main stream of the South Han River improved to 5.22% of $BOD_5$, 5.42% of T-N and 7.69% of T-P as the river flow was secured from the Seomgang. The result of this study confirms that securing the baseflow in the Seomgang according to the scenarios for securing the river flow during the dry season has a positive effect on the improvement of the water quality of the rivers in the main river of the Seomgang and South Han River. The results of this study will contribute to the establishment of reasonable management to improve the water quality of the main stream of the Seomgang and South Han River.

Establishment of Watershed Management System for Efficient Water Management in the Yeongsan and Seomjin River Basin (영산강·섬진강 수계 효율적 물관리를 위한 유역관리 시스템 구축)

  • Joung, Hee-Joung;Jung, Jae-Woon;Kim, Kap-Soon;Park, Ha-Na;Lim, Byung-Jin;Huh, Yu-Jeong;Lee, Jun-Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.2
    • /
    • pp.200-204
    • /
    • 2012
  • BACKGROUND: Recently, the project for improvement of water quality and preservation of the Yeongsan and Seomjin river basin was actively promoted. However, the publicity for many results of the project is not actively done, thus they are rarely used. Furthermore, there are not sufficient information about the projects preformed by other research institutions. Therefore, the watershed management system for efficient water management is needed in the Yeongsan and Seomjin river basin. CONCLUSION: Firstly, establishment of the Yeongsan and Seomjin river basin management research center, Secondly, construciton of wed-based water management research network. These results will serve as a basic data for efficient water management.

LCC Analysis of a Heat Pump System Using River Water (하천수 열원 이용 열펌프 시스템의 LCC 분석)

  • Han, Sang-Soo;Park, Cha-Sik;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1424-1428
    • /
    • 2009
  • The performance of a heat pump using river water as a heat source was compared with that of a conventional air-conditioner for cooling and a boiler system for heating. The heat pump system using river water considered the 1-stage cycle for cooling and the 2-stage cycle for heating. The COPs of the river water source heat pump were $0.5{\sim}1.1$ higher than those of the conventional system in the cooling season. The LCC of the river water source heat pump system was lower 13.5% and 32.4% than that of the conventional system I and II. In addition, when the initial cost ratios of the river water source heat pump system to the conventional system I and II were less than 1.2 and 1.4, respectively, an acceptable payback was found to be less than 5 years.

  • PDF

An initial study on ecological environment changes after emergent water transportation at lower reaches of Tarim River, China based on remote sensing technique

  • Jianli, Zhang;Lin, Li;Longjiang, Du
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.313-315
    • /
    • 2003
  • Tarim River is the longest continental river in China. Its downstream ecological environment declination and valley remedy got great concern. To improve ecological environment of lower Tarim River, “Emergent water transportation project for Tarim river valley remedy” was carried out from May 2000. Water was transported five times till May 2003. Several periods MODIS image was used to monitor water body in river channel. Two periods ETM image was used to interpreter changes of environment. Area of vegetation in 1999 was similar with 2001, but become better in total. The normalized difference vegetation index (NDVI) and vegetative coverage reflected environment changed better.

  • PDF