• 제목/요약/키워드: Rinse rate

검색결과 29건 처리시간 0.02초

제올라이트 흡착제 상에서 이산화탄소 회수를 위한 PSA 공정 연구: 공정성능에 대한 세정유량의 영향 (Study of PSA Process for Carbon Dioxide Recovery over Zeolite Adsorbent: Effect of Rinse Rate on Process Performance)

  • 전종기;박영권;주국택
    • 한국대기환경학회지
    • /
    • 제20권1호
    • /
    • pp.99-110
    • /
    • 2004
  • In order to investigate the performance of carbon dioxide PSA over zeolite adsorbent, the present study showed results of isotherm measurement, cyclic operation of 3-bed apparatus, and the corresponding numerical simulation. The experiment data of bed temperature, purity, recovery were matched well with that of numerical simulation. Purity of both gas and adsorbent phase increased rapidly with rinse rate but the degree of increase was retarded for large rinse rate The total amount of adsorbed increased only 10% even if rinse rate was enlarged to 4 times. Optimal rinse rate was 7N㎥/hr in this study. The heating rinse led to augments in recovery and productivity, possibly thanks to ease of description resulting from increased volumetric rinse rate and temperature rise in the column.

전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생 (The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis)

  • 윤용수
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF

반도체 패키지용 Au Wire의 표면처리용 린스 성분에 따른 표면오염 비교 연구 (A Correlation Study on Surface Contamination of Semiconductor Packaging Au Wire by Components of Rinse)

  • 김하영;추연룡;임지수;박규식;김지원;강다희;라윤호;제갈석;윤창민
    • 접착 및 계면
    • /
    • 제25권2호
    • /
    • pp.63-68
    • /
    • 2024
  • 본 연구에서는 반도체 패키지용 와이어 본딩 공정에서 금(Au) wire의 표면처리에 적용되는 린스의 종류에 따른 Au wire의 오염 현상을 확인하고자 하였다. Au wire의 표면처리를 위해 실리콘(Si) 성분이 함유된 린스와 유기 계통으로만 이루어진 린스를 주로 사용하고 있으며, 실제 영향성을 확인하기 위해 두 종류의 1.0wt% 린스 용액으로 Au wire에 표면처리를 진행하였다. 이후, 반도체 공정에서 발생할 수 있는 Si 성분이 포함된 분진과의 반응성을 확인하기 위한 모사 실험을 진행하였다. 그 결과, optical microscopy(OM) 및 scanning electron microscopy(SEM) 분석을 통해 Si 성분이 함유된 린스로 표면처리한 Au wire의 경우 분진이 다량 흡착되었으며, 유기 계통으로만 이루어진 린스로 표면처리한 Au wire에는 소량의 분진이 흡착된 것을 확인하였다. 이는 Si 성분이 함유된 린스의 경우 상대적으로 극성을 띠기에, 주성분이 극성인 분진과 극성 상호작용을 일으키기 때문이다. 따라서 Si 성분이 존재하지 않는 린스를 사용하여 Au wire를 표면처리할 경우 분진에 의한 오염 현상이 감소하여 실제 와이어 본딩 공정에서 불량률을 낮추는 효과를 볼 수 있을 것으로 기대한다.

수종의 구취처치법의 구치감소효과에 관한 연구 (Effect of Tongue Scraping, ZnCl2 Mouth Rinse, and Periodontal Treatment on the Reduction of Oral Malodor)

  • 박종훈;한경수;김문규
    • Journal of Oral Medicine and Pain
    • /
    • 제25권1호
    • /
    • pp.41-51
    • /
    • 2000
  • This study was performed to investigate the effect of three modalities commonly used for reduction of oral malodor and to review the contributing factors for halitosis. For this study, 45 subjects of good general health in their third decades were selected, and they were divided into three groups by each modality, that is, tongue scraping, $ZnCl_2$ mouth rinse, and periodontal treatment. Subjective sense of halitosis, diets, Oral hygiene index based on tooth brushing and tongue brushing habit, resting salivary flow rate, gingival index, degree of tongue coating were recored in the Halito-Chart designed by the author. Oral malodor converted from volatile sulfur compound was measured by the Halimeter$^{(R)}$(Interscan Co., USA), and the correlation between the oral factors and pre-treatment halimeter score were analysed. Data obtained were analysed by the SPSS windows program and the results of this study were as follows : 1. There were no significant correlation between oral factors such as oral hygiene index, salivary flow rate, gingival index, degree of tongue coating and pre-treatment halimeter score. 2. Difference between pre- and post-treatment halimeter score by the three modalities were significant, but correlation between pre- and post-treatment score within group was most significant in the periodontal treatment group followed by the tongue scraping group and lowest in the $ZnCl_2$ mouth rinse group. 3. Reduction of halimeter score was significant only in subjects with relatively more tongue coating in the tongue scraping group, but in the $ZnCl_2$ mouth rinse group and in the periodontal treatment group, the modality applied to each group had same significant effects without regard to the degree of oral hygiene index or gingival index. 4. Men had more tongue coating than women, and reduction of halimeter score was significant in men, but not in women.

  • PDF

이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향 (Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water)

  • 황택성;이진혁
    • 폴리머
    • /
    • 제26권5호
    • /
    • pp.551-558
    • /
    • 2002
  • 술폰산형 섬유이온교환체를 이용하여 도금 폐수 중 니켈 이온 분리를 위해 각각의 조건에 따른 니켈 이온에 대한 흡착 특성을 관찰하였다. 술폰산형 섬유이온교환체의 함수율은 술폰화도 극성이 클수록 크게 나타났으며 이온교환용량은 술폰화도가 증가함에 따라 증가하였으며 술폰화도 16%에서 3.38 meq/g로 높게 나타났다. 니켈이온의 흡착은 pH 변화에 따라 크게 변화하지 않았고 모든 흡착은 10분 이내에 약 7.5 mg/min의 흡착속도로 매우 빠르게 평형에 도달하였다. 재생 시 흡착용량은 7회까지 3.15 meq/g으로 거의 100% 가까이 탈착되었으며 그 이상에서는 2.01 meq/g으로 약간 감소하는 것으로 보아 본 연구에 사용한 이온교환체는 내구성에 문제가 없는 것으로 판단되었다. 한편 흡착평형 시간은 L/D의 값이 증가함에 따라 선형적으로 증가하였으며, 최대 흡착용량은 각각 2.71∼3.01 meq/g으로 약간 증가하였고 L/D의 변화에 크게 영향이 없는 것으로 보아 L/D<2로 흡착칼럼의 설계가 가능할 것으로 사료되었다. 또한 이온교환 섬유의 충전비가 일정할 때 pH 변화에 따른 니켈 이온의 흡착량은 산성 pH에서는 큰 변화가 없는 것으로 보아 도금수세액의 pH가 산성인 점을 고려할 때 pH 5 이하가 적합한 것으로 판단되었다.

자일리톨과 소르비톨 양치가 우식활성도에 미치는 영향 (The effects of xylitol and sorbitol mouth rinse on caries activity)

  • 이승훈;사공준
    • 한국치위생학회지
    • /
    • 제15권2호
    • /
    • pp.311-317
    • /
    • 2015
  • Objectives: The purpose of this study was to identify the effects of xylitol and sorbitol mouth rinse on the salivary caries activity levels. Methods: The study subjects were 38 female college students in Gyeongju, Korea. The subjects visited the institution once a week for 4 weeks and the saliva samples were measured for the amount of salivary caries activity levels. The saliva was collected 5 times and incubated in Mitis Salivarius Agar for 48 hours(VS-1203P3L, Vision, Korea) and measured. Results: The Streptococcus mutans CFU decreased by statistically significant amounts as compared to before the experiment within the xylitol group and the sorbitol group(p<0.01). After three weeks of mouth rinse application, Streptococcus mutans CFU of the xylitol group and the sorbitol group showed statistically significant differences(p<0.05). The salivary flow rates within the xylitol group and sorbitol group increased by statistically significant amounts(p<0.01) than before the test. The change in the salivary buffering capacity decreased by a statistically significant amount as compared to before experiment within the xylitol group(p<0.01). Conclusions: The salivary caries activity levels decreased after using xylitol and sorbitol mouth rinse in CFU and the flow rate. The buffering activity levels increased within the xylitol group. Further follow-up studies would be necessary to identify the various effects of xylitol.

일부 초등학교 학생의 불소용액양치 유무에 따른 구강보건 행태 조사 (Oral health behavior according to the experience of fluoride mouth rinse in some elementary school students)

  • 이은경;박정현;조미숙
    • 한국치위생학회지
    • /
    • 제13권6호
    • /
    • pp.1057-1062
    • /
    • 2013
  • Objectives : The purpose of this study was to investigate the possible differences in elementary schools jointed to fluoride mouth rinse plans in health centers. Methods : Students from the third to sixth grades filled out the questionnaires. Data were analyzed by the statistical package SPSS 12.0. Results : The rate of a personal toothbrush holding and toothbrushing after lunch were higher in those who rinsed their mouths with fluoride than those who did not.(p<0.05). Toothbrushing by the rolling method was more prevailing in the students who rinsed their mouths with fluoride(57.0%) and having regular dental checkup(p<0.05) than in those who did not(39.8%). Conclusions : The students who had rinsed their mouths with fluoride showed the good oral health behavior. Continuing good quality of oral health care education must be provided to the students by professional dental hygienists.

이온교환과 전기투석을 이용한 니켈회수의 비교연구 (Comparative Study on Recovery of Nickel by Ion Exchange and Electrodialysis)

  • 심주현;서형준;서재희;김대환
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.640-647
    • /
    • 2006
  • 도금공장에서 발생하는 폐수에는 니켈 등 중금속이 고농도로 함유되어 있어 그 처리가 매우 어려운 편이며, 최근에는 공해물질의 발생을 사전에 예방하는 공정을 도입하거나, 발생된 폐수 및 폐기물을 적절히 처리하여 재활용하는 청정기술이 도입되는 추세이다. 본 연구에서는 니켈 도금 공정에서 발생되는 폐수를 대상으로 이온교환과 전기투석 공정을 이용하여 니켈의 회수가능성 및 효율을 평가하였다. 이온교환수지 5 종을 이용한 이온교환 실험결과 S 1467(gel-type 강산성 양이온 교환수지)의 교환용량이 가장 높았으며 재생실험결과 4 N HCl을 재생재로 사용한 경우에서 재생율 및 재생농도가 가장 높았다. 전류밀도, 전극액 농도, 농축액 및 전극액 유량을 변화시켜가며 운전한 전기투석 실험결과 최적의 운전조건은 전류밀도 $250A/m^2$, 전극액 농도 2 N $H_2SO_4$, 전극액 및 농축액 유량 30 mL/min였다. 이온교환수지 500 mL를 사용한 이온교환 scale-up 실험결과 S 1467 수지의 교환용량은 1.88 eq/L resin, 재생율은 93.7% 이었고 cell pair 수를 2개로 증가시킨 전기투석의 scale-up 실험결과, 농축 및 희석효율은 증가하였으나, 전류효율은 일정하였다.

Removal of Organic Wax and Particles on Final Polished Wafer by Ozonated DI Water

  • Yi, Jae-Hwan;Lee, Seung-Ho;Kim, Tae-Gon;Lee, Gun-Ho;Choi, Eun-Suck;Park, Jin-Goo
    • 한국재료학회지
    • /
    • 제18권6호
    • /
    • pp.307-312
    • /
    • 2008
  • In this study, a new cleaning process with a low cost of ownership (CoO) was developed with ozonated DI water ($DIO_3$). An ozone concentration of 40 ppm at room temperature was used to remove organic wax film and particles. Wax residues thicker than $200\;{\AA}$ remained after only a commercial dewaxer treatment. A $DIO_3$ treatment in place of a dewaxer showed a low removal rate on a thick wax layer of $8000\;{\AA}$ due to the diffusion-limited reaction of ozone. A dewaxer was combined with a $DIO_3$ rinse to reduce the wax removal time and remove wax residue completely. Replacing DI rinse with the $DIO_3$ rinse resulted in a surface with a contact angle of less than $5^{\circ}$, which indicates no further cleaning steps would be required. The particle removal efficiency (PRE) was further improved by combining a SC-1 cleaning step with the $DIO_3$ rinsing process. A reduction in the process time was obtained by introducing $DIO_3$ cleaning with a dewaxing process.

Risk Assessment of Triclosan, a Cosmetic Preservative

  • Lee, Jung Dae;Lee, Joo Young;Kwack, Seung Jun;Shin, Chan Young;Jang, Hyun-Jun;Kim, Hyang Yeon;Kim, Min Kook;Seo, Dong-Wan;Lee, Byung-Mu;Kim, Kyu-Bong
    • Toxicological Research
    • /
    • 제35권2호
    • /
    • pp.137-154
    • /
    • 2019
  • Triclosan (TCS) is an antimicrobial compound used in consumer products. The purpose of current study was to examine toxicology and risk assessment of TCS based on available data. Acute toxicities of oral, transdermal and inhalation routes were low, and phototoxicity and neurotoxicity were not observed. Topical treatment of TCS to animal caused mild irritation. TCS did not induce reproductive and developmental toxicity in rodents. In addition, genotoxicity was not considered based on in vitro and in vivo tests of TCS. It is not classified as a carcinogen in international authorities such as International Agency for Research on Cancer (IARC). No-observed-adverse-effect level (NOAEL) was determined 12 mg/kg bw/day for TCS, based on haematoxicity and reduction of absolute and relative spleen weights in a 104-week oral toxicity study in rats. Percutaneous absorption rate was set as 14%, which was human skin absorption study reported by National Industrial Chemicals Notification and Assessment Scheme (NICNAS) (2009). The systemic exposure dosage (SED) of TCS has been derived by two scenarios depending on the cosmetics usage of Koreans. The first scenario is the combined use of representative cosmetics and oral care products. The second scenario is the combined use of rinse-off products of cleansing, deodorants, coloring products, and oral care products. SEDs have been calculated as 0.14337 mg/kg bw/day for the first scenario and 0.04733 mg/kg bw/day for the second scenario. As a result, margin of safety (MOS) for the first and second scenarios was estimated to 84 and 253.5, respectively. Based on these results, exposure of TCS contained in rinse-off products, deodorants, and coloring products would not pose a significant health risk when it is used up to 0.3%.