• Title/Summary/Keyword: Ring-light

Search Result 219, Processing Time 0.023 seconds

The Development of PLS-II Storage-ring Girder Systems at PAL (방사광 가속기 PLS-II 저장링 거더 시스템 개발)

  • Kim, Seungnam;Lee, Chaesun;Lee, Honggi;Kim, Kwangwoo;Nam, Sanghun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.690-697
    • /
    • 2013
  • The magnets and vacuum chambers, which are the main facilities of the Pohang light source are installed on the storage-ring girders. System safety and reliability should be taken into account for the precise operating of the main facilities, so vibration analysis is essential to do this. Static and seismic analyses were performed for the design of structure considering safety, and also frequency and response spectrum analyses were performed for the precise alignment. With these results, the effects of surrounding vibration were checked. This paper explains about the design and vibration analysis of girder systems.

Development of a Ring-type Wearable Healthcare Device (반지 형태의 웨어러블 헬스케어 디바이스 개발)

  • Baek, Hyun Jae;Cho, Jaegeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.892-897
    • /
    • 2018
  • Due to population aging, an increase in the number of patients with chronic illnesses, and an increase in the number of single-person households, monitoring of health status in everyday life without the need for a hospital has become very important. For this reason, researches on various health care devices have been attempted, among which wearable devices are attracting much attention. In this paper, we propose a new ring-type wearable device for next generation healthcare. On the inner side of the ring, a metal electrodes for GSR measurement and an optical sensor for measurement of pulse wave signals of two wavelengths of red and near-infrared light were mounted. In addition, it was equipped with an acceleration sensor, and information about the degree of motion could be obtained. In this paper, it is shown that a health monitoring device can be implemented in the form of a ring, and the measured signals can be used to calculate heart rate, oxygen saturation, sleep time and sleep efficiency. Through the advanced algorithm, it is expected that we can extract various health information, especially sleep related health information by using the ring device, and it is also expected that it can contribute to the implementation of wearable healthcare effectively.

Consideration of a Circumsolar Dust Ring in Resonant Lock with the Venus

  • Jeong, Jin-Hoon;Ishiguro, Masateru
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.54-54
    • /
    • 2010
  • Interplanetary space is filled with dust particles originating mainly from comets and asteroids. Such interplanetary dust particles lose their angular momentum by olar radiation pressure, causing the dust grains to slowly spiral inward Poynting-Robertson effect). As dust particles move into the Sun under the influence of Poynting-Robertson drag force, they may encounter regions of resonance just outside planetary orbits, and be trapped by their gravities, forming the density enhancements in the dust cloud (circumsolar resonance ring). The circumsolar resonance ring near the Earth orbit was detected in the zodiacal cloud through observations of infrared space telescopes. So far, there is no observational evidence other than Earth because of the detection difficulty from Earth bounded orbit. A Venus Climate Orbiter, AKATSUKI, will provide a unique opportunity to study the Venusian resonance ring. It equips a near-infrared camera for the observations of the zodiacal light during the cruising phase. Here we consider whether Venus gravity produces the circumsolar resonance ring around the orbit. We thus perform the dynamical simulation of micron-sized dust particles released outside the Earth orbit. We consider solar radiation pressure, solar gravity, and planetary perturbations. It is found that about 40 % of the dust particles passing through the Venus orbit are trapped by the gravity. Based on the simulation, we estimate the brightness of the Venusian resonance ring from AKATSUKI's locations.

  • PDF

Vibration Analysis of Turbocharger Rotor-Bearing System (과급기 축계의 진동 해석)

  • Suk, Ho-Il;Yang, Bo-Suk;Song, Jin-Dea
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.400.2-400
    • /
    • 2002
  • Recently rotating machines have became high speed and high Power and light weight. Bearings are one of the main components which influence power loss and stability of rotating machines. Appropriate bearing should be selected with considering characteristics of rotating machine. Floating ring journal bearing(FIB) consists of an inner film and outer film, and possess high damping and stability. FJB has been for adopted into turbocharger for the high stability at high operating speed. (omitted)

  • PDF

Vortex Ring, Shock-Vortex Interaction, and Morphological Transformation Behind a Finite Cone

  • Jang, Seo-Myeong;Jang, Geon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1599-1604
    • /
    • 2001
  • Axisymmetric compressible flow field induced by shock diffraction from a finite cone is investigated with experimental and computational methods. Double-exposure holographic interferograms show ima ges of the density field integrated along the light path. Using the sight-integrated density based on the Able transformation, the axisymmetric computational results are compared qualitatively with the experiment. In the present paper, we observed some distinguishing flow physics: the fault structure of vortex ring, the shock-vortex interaction, and the morphological transformation of shock waves.

  • PDF

Design of shunt structure to avoide TE mode in PLS-II storage ring vacuum chamber

  • Ju, Yeong-Do;Ha, Tae-Gyun;Park, Seong-Ju;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.42-42
    • /
    • 2010
  • We, previously, proved that the noise in the vertical readback from some of beam position monitors (BPMs) in the vacuum chamber of Pohang Light Source (PLS) are caused by the transverse electric (TE) longitudinal harmonic resonances. Based on this analysis, we now design the shunt structure to remove the TE mode resonces near the BPMs operation frequency of 500 MHz in the storage ring vacuum chamber of PLS upgrade project (PLS-II). The simulation result and experimental test result will be presented.

  • PDF

Photoaddition Reaction of 5,7-Dimethoxycoumarin with Adenosine

  • Cho, Tae-Heung;Shim, Hyun-Kwan;Shim, Sang-Chul
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.3
    • /
    • pp.206-211
    • /
    • 1987
  • The photoreaction of 5,7-dimethoxycoumarin with adenosine has been carried out in a dry film state. The mixture of DMC and adenosine was irradiated with 350 nm UV light and two major products were isolated. The structure was determined by various spectroscopic measurements involving $^{13}C$ nuclear magnetic resonance and fast atom bombardment mass spectrometry. These addition products were produced by covalent bond formation between the pyrone ring at carbon 3 or 4 and the sugar ring moiety of adenosine at carbon 5'.

Preparation of Novel Fused Ring Spiro[benzotetraphene-fluorene] Derivatives and Application for Deep-Blue Host Materials

  • Kim, Min-Ji;Lee, Chil-Won;Gong, Myoung-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.1639-1646
    • /
    • 2014
  • A series of novel fused-ring spiro compounds, spiro[benzo[ij]tetraphene-7,9'-fluorene] (SBTF) derivatives containing an end-capping aryl substituent at both the C3 and C10-positions hasbeen designed and synthesized via multi-step Suzuki coupling reactions. 3-(1-Naphthyl)-10-phenylSBTF (1N-PSBTF), 3-(2-naphthyl)-10-phenylSBTF (2N-PSBTF) and 3-[4-(1-naphthyl)phenyl]-10-phenylSBTF (NP-PSBTF) showed improved glass transition temperatures ($T_g$) with good thermal stability. Their photophysical, electrochemical, and electroluminescent properties were investigated and were used to construct blue organic light emission diodes (OLEDs). The typical OLED devices showed excellent performance; the NP-PSBTF-based device exhibited highly efficient deep blue-light emission with a maximum efficiency of 5.27 cd/A (EQE, 4.63%) with CIE (x = 0.133, y = 0.144). According to these characteristics, these deep-blue light emitting materials have sufficient potential for fluorescent OLED applications.

Online Strain Measurement at Multiple Points on a Rotating Blade with Fiber Bragg Grating Sensors and a Rotary Optical Coupler (광섬유 격자 센서와 회전 광학 커플러를 사용한 회전하는 블레이드 여러 지점에서의 온라인 변형률 측정)

  • Lee, Jong-Min;Hwang, Yo-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.77-82
    • /
    • 2008
  • Strain-gauges have been dominantly used to measure strain at various points on a rotor, however, either a slip ring or telemetry has to be used to send sensor signals to data acquisition instruments at stationary side. Both slip ring and telemetry have numerous inherent problems which force severe limitations in real applications. This paper introduces a new rotor condition monitoring system using FBG(Fiber Bragg Grating) sensors and a rotary optical coupler. A single optical fiber with many FBG sensors is installed on the rotor and an optical dynamic interrogator is installed at stationary side. The sensor signal connection between rotating part and stationary part is made by the rotary optical coupling method which makes use of light's unique characteristic-light travels through space. Broad band light source from the interrogator travels to the optical fiber on the rotor and reflected FBG sensor signals travel back to the optical fiber on stationary side and are connected to the interrogator. Rotary optical coupler's insertion loss change due to rotation is compensated by using a reference sensor installed at the center of the rotor. The proposed system's performance has been successfully demonstrated by accurately measuring strains at 5 points on a blade rotating at high speed.

Development of 7.5T Superconducting Wiggler for Pohang Light Source (포항방사광가속기용 중심자장7.5T를 초전도위글러 개발)

  • Bae, D.J.;Sohn, Y.U.;Yoon, Y.D.;Kim, D.E.;Seo, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.18-20
    • /
    • 1995
  • This paper describes a 7.5T magnetic flux density superconducting wiggler that minimize net angular deflection and displacement of an electron rotating along the orbit at storage ring in Pohang Light Source. It consist of dipole superconducting magnet,high uniformity flux distribution due to current source supply,cryostat,vacuum chamber,measurement system. In this paper magnet design procedure, manufacturing, experimental results are contained.

  • PDF