• Title/Summary/Keyword: Ring test

Search Result 769, Processing Time 0.026 seconds

A Study of Threshold Determination of The GPS measurement failure using GPS Code-Carrier Divergence Test (GPS 의사거리-반송파 위상 측정치의 고장검출을 위한 임계값 결정 연구)

  • Son, Eunseong;Kim, Koon-Tack;Im, Sung-Hyuck;Lee, Eun-Sung;Heo, Moon Beom;Nam, Gi-Wook
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • In this study, The code-carrier divergence test was applied to GPS measurements, and the results were compared and analyzed. The GPS data used for the threshold determination were obtained from Global Navigation Satellite System permanent stations built by the Korea Aerospace Research Institute. At each permanent station, identical dual-frequency receiver and choke ring antenna with radome are installed. The analysis method, root mean square values were compared and analyzed for each permanent station and satellite. As a result, the root mean square value generally decreased as the satellite elevation angle increased although the trend was gentle. Threshold were finally selected based on the average and standard deviation of root mean square for each permanent station. For improving of availability and continuity in real-time operation when the threshold is over the limits, Code-Carrier divergence test values are initialized.

Relationships between Biodegradation and Sorption of Phenanthrene in Slurry Bioremediation

  • ;;Bruce E. Rittmann
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.171-176
    • /
    • 2000
  • Bioremediation of hazardous hydrophobic organic compounds, such as polycyclic aromatic hydrocarbons (PAHs), is a major environmental concern due to their toxic and carcinogenic properties. Due to their hydrophobicity, the hydrophobic organic compounds are mainly associated with the soil organic matter or nonaqueous-phase liquids. A major question concerns the relationships between biodegradation and sorption. This work develops and utilizes a non- steady state model for evaluating the interactions between sorption and biodegradation of phenanthrene, a 3-ring PAH compound, in soil-slurry systems. The model includes sorption/desorption of a target compound, its utilization by microorganisms as a primary substrate existing in the dissolved phase and/or the sorbed phase in biomass and soil, oxygen transfer, and oxygen utilization as an electron acceptor. Biodegradation tests with phenanthrene were conducted in liquid and soil-slurry systems. The soil-slurry tests were performed with very different mass transfer rate: fast mass transfer in a flask test at 150 rpm, and slow mass transfer in a roller-bottle test at 2 rpm. In the slurry tests, phenanthrene was degraded more rapidly than in liquid tests, but with a similar rate in both slurry systems. Modeling analyses with several hypotheses indicate that a model without biodegradation of compound sorbed to the soil was not able to account for the rapid degradation of phenanthrene, particularly in the roller bottle slurry test. Reduced mass-transfer resistance to bacteria attached to the soil is the most likely phenomenon accounting for rapid sorbed-phase biodegradation.

  • PDF

A Study on the Characteristics of the Tube-to-Support Dynamic Impact Force Measurement Facility (튜브와 지지대 사이의 동적상호 충격력 측정장치 특성규명에 관한 연구)

  • 김일곤;박진무
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.95-106
    • /
    • 1995
  • Flow-induced vibration in heat exchanger (or fuel rod) in nuclar power plant can cause dynamic interactions between tubes and tube supports resulting in fretting-wear. To increase the reliability and design life of heat exchanger components, design criteria that establish acceptable limits of vibration and minimize fretting wear are necessary. The fretting-wear rate is dependent upon material combination, contact configuration, environmental conditions and tube-to tube support dynamic interaction. It is demostrated that the fretting -wear rate correlates well with tube-to-support contact force or work rate. The tube-to-support dynamic interaction, which consists of dynamic contact forces and tube motion, is used to relate single-span wear data to real heat exchanger configurations consisting of multi-span tube bundles. This paper describes the test facility to measure tube-to-support dynamic impact force and reports its dynamic characteristics through the four impact tests - a force transduces independent and external impact tests, central ring inside impact test and additional cylinder impact test. Through the tests the impact parameter change dependent upon the material difference of impacting ball is studied, and the impact parameters of Force Transducer Assembly components are measured. And also the dynamic behavior of Force Transducer Assembly is analyzed. The force measurement technique herein is shown to provide a reasonable measure of dynamic contact forces.

  • PDF

A Study on the Characteristics of Bearing Capacity for Rammed Aggregate Pier in Sand (사질토지반에서 짧은 쇄석다짐말뚝의 배치형태에 따른 지지력특성에 관한 연구)

  • Chun, Byung-Sik;Kim, Young-Hun;Yoo, Woo-Hyun;Kim, Jong-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.195-198
    • /
    • 2009
  • Rammed Aggregate Pier method is intermediate foundation of deep and shallow foundation, it has been built on world wide. But the investigation and research in domestic is not accomplished. In this paper, examined details of different spacing of piles, bearing capacities, respectively, conclude with recommendations on how RAP can be used in future needs. This documentation further provides comparisons of the laboratory test results which were obtained from differenciate the spacing of piles, namely installed rammed aggregate pier. Strain control test was conducted to determine the bearing capacities of the piers; 20mm, 30mm and 40mm diameter drilling equipment to drill holes were installed in sand at initial relative densities of 40%. By comparing different spacing of piles, in this experiment, piles are spaced structually span, form a ring shape, narrowing the distance of each other, to the center. the result shows that as diameter of pier is bigger in diameter, bearing capacity also dramatically increased due to raised stiffness. Also, the space between each piers narrowed, settlement rate of soil was decreased significantly. From the test results, as the space between each piles were getting closer, allows greater chances to have resistance to deformation, shows improved stability of structures.

  • PDF

Development of Hybrid Sol-Gel Coating to Prevent Corrosion of Magnesium Alloys (마그네슘 합금의 방청을 위한 하이브리드 졸-겔 코팅제의 개발)

  • Lee, Dong Uk;Kim, Young Hoon;Moon, Myung Jun
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • The high rate of corrosion of magnesium alloys makes it limited for industrial applications. Therefore, surface treatment is required to enhance their corrosion resistance. In our study, a chemical conversion coating for protecting the corrosion of the magnesium alloy, AZ31B, was prepared by using a phosphate-permanganate solution. The chemical conversion coating had a limited protection ability due to defects arising from cracks and pores in the coating layer. The sol-gel coating was prepared by using trimethoxymethylsilane (MTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS) as precursors, and aluminum acetyl acetonate as a ring opening agent. The corrosion protection properties of sol-gel and conversion coatings in 0.35wt% NaCl solution were measured by the electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization test. The EIS results indicated that the resistance of the chemical conversion coating with the sol-gel coating was significantly improved through the sol-gel sealed phosphate-permanganate conversion coating. The results of the potentiodynamic polarization test revealed that the sol-gel coating decreased the corrosion current density ($I_{corr}$). The SEM image showed that the sol-gel coating sealed conversion coating and improved corrosion protection.

Pharmacognostical Studies on Codonopsis lanceolata (더덕(사삼(沙蔘))의 생약학적 연구)

  • Kim, Chong-Hyun;Chung, Myung-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.6 no.1
    • /
    • pp.43-47
    • /
    • 1975
  • Attempts were made to determine the characteristics of the morphology of Codonopsis lanceolata $T_{RAUT's}$ root. Its saponin and crude powder were examined by foaming and hemolytic tests and by observing transverse sections: 1) The cork-layer was consisted of multiple cells, and some of the cork cells contained monoclinic prism crystals of calcium oxalates. 2) The vascular bundle was formed of radial arrangement by the preminentic bursting pith and the irregular cambium ring with the abnormal growth. 3) The latex vessel and latex of the cortex were brown-gray or yellowish-brown. The latex vessel and sieve tube were consisted of the independent aggregates which had a number of layers. It had much more independent aggregates than Platycodi Radix. 4) The xylem was less than the phloem portion. The thick-walled vessels which had one to five lines ware more distributed than in Platycodi Radix. 5) The inulin distribution on a piece of section which is dipped in alcohol was observed through out the tissues, but starch grain was not found in it. 6) The duration time of foaming reaction of the crude powder in test tubes was shorter than that of Platycodi Radix. Foaming index of the foaming test of five percent decoctions was 3.33, 7) In the hemolytic test which used 10 percent decoction and one percent saponin solution, hemolytic action was very weak.

  • PDF

Fresh and hardened properties of rubberized concrete using fine rubber and silpozz

  • Padhi, S.;Panda, K.C.
    • Advances in concrete construction
    • /
    • v.4 no.1
    • /
    • pp.49-69
    • /
    • 2016
  • This work investigates the mechanical properties of conventional concrete (CC) and self compacting concrete (SCC) using fine rubber and silpozz were accompanied by a comparative study between conventional rubberized concrete (CRC) and self compacting rubberized concrete (SCRC). Fine rubber (FR) from scrap tires has replaced the fine aggregate (FA) and Silpozz has been used as a replacement of cement at the proportions of 5, 10 and 15%. Silpozz as a partial replacement of cement in addition of superplasticiser (SP) increases the strength of concrete. Fresh concrete properties such as slump test, compaction factor test for CRC, whereas for SCRC slump flow, $T_{500}$, V-funnel, L-box, U-box, J-ring tests were conducted along with the hardened properties tests like compressive, split tensile and flexural strength test at 7, 28 and 90 days of curing. The durability and microstructural behavior for both CRC and SCRC were investigated. FR used in the present study is 4.75 mm passing with fineness modulus 4.74.M30 grade concrete is used with a mix proportion of 1:1.44:2.91 and w/c ratio as 0.43. The results indicate that as FR quantity increases, workability of both CRC and SCRC decreases. The results also show that the replacement of natural fine aggregate (NFA) with FR particles decreases the compressive strength with the increase of flexural strength observed upto 5% replacement of FR. Also replacement of cement with silpozz resulted enhancement of strength in SCRC.

A Study on the Corrosion Behavior of Magnesium Alloy Sealed with Chemical Conversion Coating and Sol-gel Coating

  • Lee, Dong Uk;Chaudhari, Shivshankar;Choi, Seung Yong;Moon, Myung Jun;Shon, Min Young
    • Corrosion Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.175-182
    • /
    • 2021
  • Magnesium alloy is limited in the industrial field because its standard electrode potential is -2.363 V vs. NHE (Normal Hydrogen Electrode) at 25 ℃. This high electrochemical activity causes magnesium to quickly corrode with oxygen in air; chemical conversion coating prevents corrosion but causes surface defects like cracks and pores. We have examined the anti-corrosion effect of sol-gel coating sealed on the defected conversion coating layer. Sol-gel coatings produced higher voltage current and smaller pore than the chemical conversion coating layer. The conversion coating on magnesium alloy AZ31 was prepared using phosphate-permanganate solution. The sol-gel coating was designed using trimethoxymethylsilane (MTMS) and (3-Glycidyloxypropyl) trimethoxysilane (GPTMS) as precursors, and aluminum acetylacetonate as a ring-opening agent. The thermal shock resistance was tested by exposing specimens at 140 ℃ in a convection oven; the results showed changes in the magnesium alloy AZ31 surface, such as oxidization and cracking. Scanning electron microscope (FE-SEM) analysis confirmed a sealed sol-gel coating layer on magnesium alloy AZ31. Electrochemical impedance spectroscopy (EIS) measured the differences in corrosion protection properties by sol-gel and conversion coatings in 0.35 wt% NaCl solution, and the potentiodynamic polarization test and confirmed conversion coating with the sol-gel coating show significantly improved resistance by crack sealing.

Study on the Mechanical Face Seal Performance for a 7-ton-Class Turbopump (7톤급 터보펌프 기계평면실의 성능 시험 연구)

  • Bae, Joonhwan;Kwak, Hyun D.;Choi, Changho
    • Tribology and Lubricants
    • /
    • v.32 no.5
    • /
    • pp.154-159
    • /
    • 2016
  • This paper presents an experimental study of the leakage performance and endurance performance of a mechanical face seal in the 7-ton-class turbopump of the Korea Space Launch Vehicle 2 third-stage engine. We install a mechanical face seal between the fuel pump and turbine to prevent the mixing of the fuel and turbine gas. We design and manufacture a prototype mechanical face seal, which has two parts, namely, a bellows seal assembly and mating ring. We set up a test facility to measure the leakage and endurance of the mechanical face seal. For the similarity tests, we use water under real operating conditions such as high rotational speed, high temperature, and high pressure. Through investigation of the leakage and carbon wear rate, it is possible to evaluate the performance of the mechanical face seal. The results of the leakage and endurance performance test demonstrate the absence of any leakage from the prototype mechanical face seal after a trial run and clarify that the acceptable wear rate fully satisfies the turbopump requirements. Finally, we install a qualified mechanical face seal in a 7-ton-class turbopump and perform a validation test in the turbopump real-propellant test facility in the Korea Aerospace Research Institute. The test results confirm that the mechanical face seal works well under real operating conditions.

Studies on Virus Diseases of Orchids in Korea (우리나라 란 바이러스에 관한 연구)

  • Lee Hyun Sook;La Yong Joon
    • Korean journal of applied entomology
    • /
    • v.15 no.3 s.28
    • /
    • pp.137-145
    • /
    • 1976
  • Orchids have been propagated vegetatively for a long time without adequate control measures against virus diseases in Korea. As a result, it is presumed that most of the orchid varieties in Korea may have been degenerated. Nevertheless there has been little work on the virus diseases of orchids in Korea. Therefore studies were initiated to isolate an4 characterize the orchid viruses occurring in Korea. The results obtained are summerized as follows. 1. Symptoms of virus diseases on orchid varieties can be grouped 1) mosaic, 2) necrotic streak with mosaic, 3) ring necrosis, 4) chlorotkc ring and 5) necrotic spot. 2. A total of 102 orchid plants representing 4 genera were investigated on the occurrence of Cymbidium mosaic virus and tobacco mosaic virus by serological agar-gel double diffusion test. The test revealed that approximately $45\%$ of the orchids were infected with Cymbidium mosaic virus. None of the plants were found to be infected with tobacco mosaic virus. 3. Local lesions appeared on the inoculated leaves of Chenopodium amaranticolor Cassia occidentalis and Datura stramonium 7-12 days after mechanical inoculation with Cymbidium mosaic virus. 4. Physical properties of the Cymbidium mosaic virus determined by inoculation on Chenopodium amaranticolor were as follows: Thermal inactivation Point; $75-80^{\circ}C$, dilution end Point; $10^{-5}-10^{-6}\%$ aging in vitro; 8 days. 5. Three different buffers at pH 7.0 and pH 9.0 were compared for the efficiency of agar-gel double diffusion test with Cymbidium mosaic virus. Phosphate, imidazol and tris buffer at pH 7.0 gave equally satisfactory results. 6. Electron microscopic examination of the Cymbidium mosaic virus revealed rod shaped particles measuring 460-580mu.

  • PDF