• 제목/요약/키워드: Ring system

검색결과 1,230건 처리시간 0.033초

레이저 자극과 O-Ring 경근 측정시스템에 의한 체질진단의 객관화에 관한 연구 (A Study on Objective Diagnosis of constitutions by Laser Stimulation and O-Ring Measurement Systems of Muscular Meridians)

  • 김양영;김주명;이의원;정동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.173-178
    • /
    • 1995
  • This paper relates the occidental constitutional theory to the oriental one, concluding their origins to be similar, and demonstrates a new method of constitutional diagnosis by O-Ring Measurement System Of Muscular Meridians and Laser Constitutional Diagnosis. It establishes Laser Constitutional Diagnosis(L.C.D) using laser beams according to the principles of acupuncture and Sa-Sang constitutional physiology under the effect of spatial morphological energy of geometric isomers. Finally, hypothetical theory of L.C.D. was experimented by the O-Ring Measurement Systems of Muscular Meridians(O-R MSMM). O-R MSMM has been specially devised to improve the manual O-Ring Test prevailing to distinguish energetic response by muscle tonicity. Statistically, it has been proved that the constitutional diagnosis with O-R MSMM was highly effective and objective in the clinical experiences.

  • PDF

Reconstruction of In-beam PET for Carbon therapy with prior-knowledge of carbon beam-track

  • Kim, Kwangdon;Bae, Seungbin;Lee, Kisung;Chung, Yonghyun;An, Sujung;Joung, Jinhun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권6호
    • /
    • pp.384-390
    • /
    • 2015
  • There are two main artifacts in reconstructed images from in-beam positron emission tomography (PET). Unlike generic PET, in-beam PET uses the annihilation photons that occur during heavy ion therapy. Therefore, the geometry of in-beam PET is not a full ring, but a partial ring that has one or two openings around the rings in order for the hadrons to arrive at the tumor without prevention of detector blocks. This causes truncation in the projection data due to an absence of detector modules in the openings. The other is a ring artifact caused by the gaps between detector modules also found in generic PET. To sum up, in-beam PET has two kinds of gap: openings for hadrons, and gaps between the modules. We acquired three types of simulation results from a PET system: full-ring, C-ring and dual head. In this study, we aim to compensate for the artifacts that come from the two types of gap. In the case of truncation, we propose a method that uses prior knowledge of the location where annihilations occur, and we applied the discrete-cosine transform (DCT) gap-filling method proposed by Tuna et al. for inter-detector gap.

The 3-[3α(2α-Hydroxy)pinane]-4,5-(pinan)-1,3-oxazolidine Synthesis, Structure and Properties

  • Bialek, Magdalena;Trzesowska, Agata;Kruszynski, Rafal
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.89-94
    • /
    • 2007
  • The new pinane derivative containing unique multifused ring system was synthesized. The crystal, molecular and electronic structure of the title compound has been determined. Both pinane ring systems have the same conformation. The five-membered oxazolidine ring exists in twisted chair conformation. The structure is expanded through O-H…O hydrogen bond to semiinfinite hydrogen-bonded chain. The bond lengths and angles in the optimised structure are similar to the experimental ones. The CH3 and CH2 groups (except this of oxazolidine ring) are negatively charged whereas the CH groups are positively charged. The largest negative potential is on the oxygen atoms. The C-N natural bond orbitals are polarised towards the nitrogen atom (ca. 61% at N) whereas the C-O bond orbitals are polarised towards the oxygen atom (ca. 67% at O). It is consistent with the charges on the nitrogen and oxygen atom of oxazolidine ring and the direction of the dipole moment vector (3.08 Debye).

허브스페이스의 구조적 안전성 해석에 대한 연구 (A Study on Structural Safety Analysis of Hub Space)

  • 한문식;조재웅
    • 한국자동차공학회논문집
    • /
    • 제23권3호
    • /
    • pp.352-359
    • /
    • 2015
  • This study investigates the analysis result of structure and fatigue due to the models of the hub space with bolt joint at wheel and the existence or nonexistence of hub ring as the part of suspension system of vehicle. As the static analysis result, the structural vulnerability can be found at hub bolt and the center of wheel at three models. Model 2 and 3 have nearly same deformation and model 1 can be endured at the least load among three models. As the fatigue analysis result, fatigue lives of three models are same at the severest load of SAE bracket history. As many screw threads of weak bolts are jointed in case of model 1, model 1 is shown to be the weakest at fatigue damage among three models. By the result of this study, model 1 with bolt joint becomes most weakest among three models. As model 2 with no hub ring and model 3 with hub ring have the nearly same states of analysis results, hub ring is shown to have no influence on the safety of automotive driving.

생체 이식형 장치를 위해 구현된 403.5MHz CMOS 링 발진기의 성능 분석 (Performance Analysis of 403.5MHz CMOS Ring Oscillator Implemented for Biomedical Implantable Device)

  • 펄도스 아리파;최광석
    • 디지털산업정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.11-25
    • /
    • 2023
  • With the increasing advancement of VLSI technology, health care system is also developing to serve the humanity with better care. Therefore, biomedical implantable devices are one of the amazing important invention of scientist to collect data from the body cell for the diagnosis of diseases without any pain. This Biomedical implantable transceiver circuit has several important issues. Oscillator is one of them. For the design flexibility and complete transistor-based architecture ring oscillator is favorite to the oscillator circuit designer. This paper represents the design and analysis of the a 9-stage CMOS ring oscillator using cadence virtuoso tool in 180nm technology. It is also designed to generate the carrier signal of 403.5MHz frequency. Ring oscillator comprises of odd number of stages with a feedback circuit forming a closed loop. This circuit was designed with 9-stages of delay inverter and simulated for various parameters such as delay, phase noise or jitter and power consumption. The average power consumption for this oscillator is 9.32㎼ and average phase noise is only -86 dBc/Hz with the source voltage of 0.8827V.

고감성 의류용 PTT/울/모달 에어 볼텍스 복합사의 물성 (Physical Property of PTT/Wool/Modal Air Vortex Yarns for High Emotional Garment)

  • 김현아
    • 한국의류학회지
    • /
    • 제39권6호
    • /
    • pp.877-884
    • /
    • 2015
  • Polytrimethylene Terephthalate (PTT) is an eco-fiber with good elastic properties; however, it requires more detailed studies related to spinnability according to blending of various kinds of fibers. The evolution of spinning technology was focused on improved productivity with good quality; in addition, air vortex spinning was recently invented and applied on the spinning factory as the facility with good productivity and quality. More detail spinning technology according to the blending of various kinds of fibers on the air vortex spinning system is required to obtain good quality yarns for high emotional fabrics. In this paper, the physical properties of air vortex, compact and ring staple yarns using PTT/wool/modal blend fibers were investigated with yarn structure to promote high functional PTT that includes fabrics for high emotional garments. Unevenness of air vortex yarns was higher than those of compact and ring yarns; in addition, imperfections were greater than those of compact and ring yarns, which was attributed to a fascinated vortex yarn structure. Tenacity and breaking strain of air vortex yarns were lower than those of compact and ring yarns, caused by higher unevenness and more imperfections of air vortex yarns compared to compact and ring yarns. Vortex yarns showed the highest initial modulus and ring yarns showed the lowest ones which results in a stiff tactile feeling of air vortex yarns in regards to the initial modulus of yarns. Dry and wet thermal shrinkages of air vortex yarns were lower than ring yarns. Good shape retention of vortex yarns was estimated due to low thermal shrinkage.

Rotordynamic Characteristics of Floating Ring Seals in Rocket Turbopumps

  • Tokunaga, Yuichiro;Inoue, Hideyuki;Hiromatsu, Jun;Iguchi, Tetsuya;Kuroki, Yasuhiro;Uchiumi, Masaharu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권3호
    • /
    • pp.194-204
    • /
    • 2016
  • Floating ring seals offer an opportunity to reduce leakage flows significantly in rotating machinery. Accordingly, they have been applied successfully to rotating machinery within the last several decades. For rocket turbopump applications, fundamental behavior and design philosophy have been revealed. However, further work is needed to explore the rotordynamic characteristics associated with rotor vibrations. In this study, rotordynamic forces for floating ring seals under rotor's whirling motions are calculated to elucidate rotordynamic characteristics. Comparisons between numerical simulation results and experiments demonstrated in our previous report are carried out. The three-dimensional Reynolds equation is solved by the finite-difference method to calculate hydrodynamic pressure distributions and the leakage flow rate. The entrance loss at the upstream inlet of the seal ring is calculated to estimate the Lomakin effect. The friction force at the secondary seal surface is also considered. Numerical simulation results showed that the rotordynamic forces of this type of floating ring seal are determined mainly by the friction force at the secondary seal surface. The seal ring is positioned almost concentrically relative to the rotor by the Lomakin effect. Numerical simulations agree quite well with the experimental results.

수공구 손잡이 형태에 따른 청.노년층의 악력과 손가락 힘 및 편안함 분석 (Grip Force, Finger Force, and Comfort analyses of Young and Old People by Hand Tool Handle Shapes)

  • 공용구;손성태;김대민;정명철
    • 대한인간공학회지
    • /
    • 제28권2호
    • /
    • pp.27-34
    • /
    • 2009
  • The purpose of this study was to evaluate aging (young and old), gender (male and female), and handle shape effects on grip force, finger force, and subjective comfort. Four handle shapes of A, D, I, and V were implemented by a multi-finger force measurement (MFFM) system which was developed to measure every finger force with different grip spans. Forty young (20 males and 20 females) and forty old (20 males and 20 females) subjects participated in twelve gripping tasks and rated their comfort for all handles using a 5-point scale. Grip forces were calculating by summation of all four forces of the index, middle, ring and little fingers. Results showed that young males (283.2N) had larger gripping force than old males (235.6N), while young females (151.4N) had lower force than old females (153.6N). Young subjects exerted the largest gripping force with D-shape due to large contribution of the index and middle fingers and the smallest with A-shape; however, old subjects exerted the largest with I-shape and the smallest with V-shape due to small contribution of the ring and little fingers. As expected, the middle finger had the largest finger force and the little finger had the smallest. The fraction of contribution of index and ring fingers to grip force differed among age groups. Interestingly, young subjects provided larger index finger force than ring finger force, whereas old subjects showed that larger ring finger forces than index finger force in the griping tasks. In the relationship between performance and subjective comfort, I-shape exerting the largest grip force had less comfort than D-shape producing the second largest grip force. The findings of this study can provide guidelines on designing hand tool handle to obtain better performance as well as users' comfort.

센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템 (Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application)

  • 장인훈;심귀보
    • 한국지능시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.619-625
    • /
    • 2007
  • 블루투스, 지그비, RFID와 같은 저가의 저 전력 무선통신 기술의 실용화는 웰빙 바람과 함께 유비쿼터스 헬스케어에 대한 관심이 급격하게 증가하고 있으며 u-Health는 센서네트워크분야에서 가장 중요한 응용분야중 하나가 되고 있다. 특히 독거노인이나 실버타운의 노인을 위해 응급상황에 대한 대처가 가능한 의료서비스를 개발하는 것은 그 자체로 의미가 있으며 그 수요는 노령인구의 급속한 증가와 함께 지속적으로 늘어날 것으로 기대된다. 이에 본 논문은 일상생활에서 손가락에 착용한 반지모양의 pulse oximeter 센서에 의해 수집된 PPG 신호로부터 정확한 맥박 변화율을 이끌어내는 것에 대한 타당성을 보이고자 한다. 이를 위해 반사형과 투과형 2가지 종류의 반지센서를 제작하였으며 반지센서로부터 맥박데이터를 수집, 분석하고 응급상황에 대처할 수 있는 원격의 모니터링 시스템을 개발하였다.