• Title/Summary/Keyword: Right ventricular failure

Search Result 130, Processing Time 0.03 seconds

Right Ventricular Mass Quantification Using Cardiac CT and a Semiautomatic Three-Dimensional Hybrid Segmentation Approach: A Pilot Study

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.901-911
    • /
    • 2021
  • Objective: To evaluate the technical applicability of a semiautomatic three-dimensional (3D) hybrid CT segmentation method for the quantification of right ventricular mass in patients with cardiovascular disease. Materials and Methods: Cardiac CT (270 cardiac phases) was used to quantify right ventricular mass using a semiautomatic 3D hybrid segmentation method in 195 patients with cardiovascular disease. Data from 270 cardiac phases were divided into subgroups based on the extent of the segmentation error (no error; ≤ 10% error; > 10% error [technical failure]), defined as discontinuous areas in the right ventricular myocardium. The reproducibility of the right ventricular mass quantification was assessed. In patients with no error or < 10% error, the right ventricular mass was compared and correlated between paired end-systolic and end-diastolic data. The error rate and right ventricular mass were compared based on right ventricular hypertrophy groups. Results: The quantification of right ventricular mass was technically applicable in 96.3% (260/270) of CT data, with no error in 54.4% (147/270) and ≤ 10% error in 41.9% (113/270) of cases. Technical failure was observed in 3.7% (10/270) of cases. The reproducibility of the quantification was high (intraclass correlation coefficient = 0.999, p < 0.001). The indexed mass was significantly greater at end-systole than at end-diastole (45.9 ± 22.1 g/m2 vs. 39.7 ± 20.2 g/m2, p < 0.001), and paired values were highly correlated (r = 0.96, p < 0.001). Fewer errors were observed in severe right ventricular hypertrophy and at the end-systolic phase. The indexed right ventricular mass was significantly higher in severe right ventricular hypertrophy (p < 0.02), except in the comparison of the end-diastolic data between no hypertrophy and mild hypertrophy groups (p > 0.1). Conclusion: CT quantification of right ventricular mass using a semiautomatic 3D hybrid segmentation is technically applicable with high reproducibility in most patients with cardiovascular disease.

Temporary Right Ventricular Assist Device Insertion via Left Thoracotomy after Left Ventricular Assist Device Implantation

  • Park, Ilkun;Cho, Yang Hyun;Chung, Su Ryeun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.105-108
    • /
    • 2019
  • Right heart failure is a relatively common complication after left ventricular assist device (LVAD) implantation. Severe right heart failure can be managed by temporary right ventricular assist device (RVAD) implantation. However, trans-sternal RVAD insertion requires a subsequent third sternotomy for cannula removal. Herein, we present a case of RVAD insertion via a left anterior mini-thoracotomy after LVAD implantation in a patient with alcohol-induced cardiomyopathy.

Intensive management of acute right heart failure (급성 우심 부전의 집중 치료)

  • Kim, Gi Beom;Noh, Chung Il
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1041-1048
    • /
    • 2007
  • Not a few patients in children and adolescents are suffering from right ventricular (RV) dysfunction resulting from various conditions such as chronic lung disease, left ventricular dysfunction, pulmonary hypertension, or congenital heart defect. The RV is different from the left ventricle in terms of ventricular morphology, myocardial contractile pattern and special vulnerability to the pressure overload. Right ventricular failure (RVF) can be evaluated in terms of decreased RV contractility, RV volume overload, and/or RV pressure overload. The management for RVF starts from clear understanding of the pathophysiology of RVF. In addition to correction of the underlying disease, management of RVF per se is very important. Meticulous control of volume status, inotropic agents, vasopressors, and pulmonary selective vasodilators are the main tools in the management of RVF. The relative importance of each tool depends on the individual clinical status. Medical assist device and surgery can be considered selectively in case of refractory RVF to optimal medical treatment.

Percutaneous OxyRVAD in a Patient with Severe Respiratory Failure and Right Heart Failure: A Case Report

  • Ga Young Yoo;June Lee;Seok Beom Hong;Do Yeon Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.319-322
    • /
    • 2024
  • Venovenous extracorporeal membrane oxygenation (VV ECMO) is often used in cases of severe respiratory failure, especially in patients considered for lung transplantation. However, because many lung diseases can ultimately result in right heart failure, the treatment of secondary right heart failure can present a challenge when the patient is already under VV ECMO support. In such cases, an oxygenated-right ventricular assist device (OxyRVAD) can be used. OxyRVAD is designed to maintain anterograde blood flow and prevent right ventricular distension. Moreover, the pulmonary arterial cannula can be inserted percutaneously. We report a case in which percutaneous OxyRVAD was successfully implemented to manage right heart failure in a patient with respiratory failure who was on VV ECMO.

Right ventricular failure in congenital heart disease

  • Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.101-106
    • /
    • 2013
  • Despite developments in surgical techniques and other interventions, right ventricular (RV) failure remains an important clinical problem in several congenital heart diseases (CHD). RV function is one of the most important predictors of mortality and morbidity in patients with CHD. RV failure is a progressive disorder that begins with myocardial injury or stress, neurohormonal activation, cytokine activation, altered gene expression, and ventricular remodeling. Pressure-overload RV failure caused by RV outflow tract obstruction after total correction of tetralogy of Fallot, pulmonary stenosis, atrial switch operation for transposition of the great arteries, congenitally corrected transposition of the great arteries, and systemic RV failure after the Fontan operation. Volume-overload RV failure may be caused by atrial septal defect, pulmonary regurgitation, or tricuspid regurgitation. Although the measurement of RV function is difficult because of many reasons, the right ventricle can be evaluated using both imaging and functional modalities. In clinical practice, echocardiography is the primary mode for the evaluation of RV structure and function. Cardiac magnetic resonance imaging is increasingly used for evaluating RV structure and function. A comprehensive evaluation of RV function may lead to early and optimal management of RV failure in patients with CHD.

Complete Repair of Tetralogy of Fallot in Neonate or Infancy (신생아및 영아기 활로씨 사징증의 완전 교정술)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.25 no.1
    • /
    • pp.32-41
    • /
    • 1992
  • From August 1982 to December 1991, 58 consecutive infants with tetralogy of Fallot underwent primary repair. Age ranged from 22 days to twelve months [n=58, 8.7$\pm$2.7 months] and body weight from 3.1 to 13 kilograms [n=58, 7.8$\pm$1.7 kilograms]. Qne infant had absence of the pulmonary valve; one had Ebstein`s anomaly and one had supramitral ring. Thirty-two patients [56%] experienced anoxic spell. Preoperative pulmonary artery indices were measured in 38 cases, ranging 126-552mm2/M2BSA[n=38, 251$\pm$79mm2/M2BSA]. All infants required a right ventricular outflow tract patch; in 41, the patch extended across the pulmonary valve annulus, in 13 of them, monocusps were constructed. All had patch closure of ventricular septal defect. Two infants had REV operation for avoiding injury to the canal branch of the right coronary artery which cross the right ventricular out flow tract. Post repair PRV/LV were measured at operating room in 40 cases, which revealed mean value of 0.49$\pm$0.12 [range: 0.25-0.74]. The hospital mortality was 10.3% [6 patients], and causes of deaths were right heart failure due to sustained right ventricular hypertension[4] and right ventricular outflow tract obstruction, intractablesuraventricular tachyarrhythmia[1], hypoxia[1] due to residual right to left shunt across the atrial septal defect in patient associated with Ebstein`s anomaly. All infants were doing well at follow-up from 1 to 101 months[20.6 months /patient, 1, 072 patient-month] Serial postoperative echocardiograms revealed no residual ventricular septal defects and estimated RVOT gradients between 0 and 40 mmHg except 3 cases [50, 50, 60 mmHg]. There were no late deaths and late ventricular arrhythmias or congestive heart failure. Redo operations were done in 2 cases because of residual right ventricular outflow tract obstruction. This experience with infants with tetralogy of Fallot suggests that, if mortality is tolerable, eletive repair of tetralogy of Fallot could be reasonably undertaken during the first year of life, and even better results could be anticipated along with improvement of methods of myocardial protection and postoperative care.

  • PDF

The effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline-induced right ventricular failure

  • Bae, Hyun Kyung;Lee, Hyeryon;Kim, Kwan Chang;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.6
    • /
    • pp.262-270
    • /
    • 2016
  • Purpose: Pulmonary arterial hypertension (PAH) leads to right ventricular failure (RVF) as well as an increase in pulmonary vascular resistance. Our purpose was to study the effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline (MCT)-induced RVF. Methods: The rats were distributed randomly into 3 groups. The control (C) group, the monocrotaline (M) group (MCT 60 mg/kg) and the sildenafil (S) group (MCT 60 mg/kg+ sildenafil 30 mg/kg/day for 28 days). Masson Trichrome staining was used for heart tissues. Western blot analysis and immunohistochemical staining were performed. Results: The mean right ventricular pressure (RVP) was significantly lower in the S group at weeks 1, 2, and 4. The number of intra-acinar arteries and the medial wall thickness of the pulmonary arterioles significantly lessened in the S group at week 4. The collagen content also decreased in heart tissues in the S group at week 4. Protein expression levels of B-cell lymphoma-2 (Bcl-2)-associated X, caspase-3, Bcl-2, interleukin (IL)-6, matrix metalloproteinase (MMP)-2, endothelial nitric oxide synthase (eNOS), endothelin (ET)-1 and ET receptor A (ERA) in lung tissues greatly decreased in the S group at week 4 according to immunohistochemical staining. According to Western blotting, protein expression levels of troponin I, brain natriuretic peptide, caspase-3, Bcl-2, tumor necrosis factor-${\alpha}$, IL-6, MMP-2, eNOS, ET-1, and ERA in heart tissues greatly diminished in the S group at week 4. Conclusion: Sildenafil alleviated right ventricular hypertrophy and mean RVP. These data suggest that sildenafil improves right ventricular function.

Evaluation of Right Ventricular Function with Radionuclide Cardiac Angiography: Right Ventricular Ejection Fraction in Chronic Obstructive Lung Disease (방사선동위원소 심혈관촬영술을 이용한 우심실기능 측정에 관한 연구 -만성폐쇄성 폐질환에서의 우심실 Ejection Fraction-)

  • Sohn, In;Shin, Seong-Hae;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Lee, Young-Woo;Han, Yong-Cheol;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 1982
  • To evaluate the usefulness of radionuclide cardiac angiography in the assessment of right ventricular function, we measured right ventricular ejection fraction (RVEF) using single pass method. In 12 normal persons, RVEF averaged $52.7{\pm}5.9%(mean{\pm}S.D.)$. In 25 patients with chronic obstructive lung disease, RVEF was $37.2{\pm}10.6%$ and significantly lower than that of normal persons (p<0.01). All 10 patients with right ventricular failure had abnormal RVEF, which was significantly lower than that of 14 patients without right ventricular failure ($27.6{\pm}5.7%,\;43.9{\pm}8.5%$, respectively. p<0.01). It concluded thal RVEF measured by single pass radionuclide cardiac angiography was a useful, noninvasive method to assess right ventricular function.

  • PDF

Right Ventricular Outflow Tract Reconstruction with Bovine Jugular Venous Valved Conduit. (소경정맥 판막도관을 이용한 우심실 유출로 재건술)

  • 박형주
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.830-833
    • /
    • 2000
  • Homograft has been the conduit of choice in various types of congenital malformations which require right ventricular outflow tract reconstruction. However it has been proven to be less than ideal in young age group because of early failure of the conduite due to valve dysfunction and calcification. Furthermore limitation of availability of homograft particularly small sized conduits for neonates and infants is the most serious problem. A 19 month old female patient with pulmonary atresia and ventricular septal defect was operated on with a bovine jugular venous valved conduit as an alternative to the homograft for her right ventricular outflow tract reconstruction. Postoperative hemodynamic performance of the conduit was excellent without pressure gradient or valve regurgitation. With this early result bovine jugular venous valved conduit seems to be another excellent conduit because of good hemodynamics and size availability but long term follow up is necessary.

  • PDF

Traumatic ventricular septal defect - One case report - (외상성 심실중격결손증 1례 보)

  • 성후식
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.411-415
    • /
    • 1987
  • We have experienced a rare case of traumatic ventricular septal defect caused by fall down injury. The patient suffered from congestive heart failure after trauma and represented new developing typical murmur. Cardiac catheterization revealed a large left-to-right shunt at the ventricular level and a 4.4:1 ratio of pulmonary to systemic flow. Left ventricular angiogram also showed ventricular septal defect low in the muscular septum. At operation, the right ventricle and pulmonary artery were found to be moderately dilated. A marked systolic thrill was palpable over the right ventricle near the apex. Through a small left ventriculotomy an oval defect, 2x.3 cm with a firm scarred margin, was found in the lower muscular ventricular septum. This defect was repaired using Dacron patch and ventriculotomy was closed with long strip of Teflon felt. Postoperative course was uneventful and discharged in good condition.

  • PDF