• Title/Summary/Keyword: Ridge Axis Protection

Search Result 2, Processing Time 0.018 seconds

A Study on the Usefulness of the Ridge in Open Space and Landscape Planning (녹지 및 경관계획에 있어서 능선의 효용성에 관한 연구)

  • Lee, Won-Young;Choi, Hyung-Seok
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.5
    • /
    • pp.70-78
    • /
    • 2003
  • From the viewpoint of the importance of the division theory based on topography(pyungsu) derived from the uniqueness in topography, not to mention of the function of ridge in ruban areas, the destroy of ridges should be prevented from the development of hill areas. This study intends to propose the basic concepts and principles to protect the ridge axis with green in open space and landscape planning. The main results are summarized as follows : First, eco-bridge across the ridges will be connected for the purpose of ecosystem restoration. Second, the protection and restoration of green ridge axis can be completed by Green Structure Plan which has principles and standards such as. - layout of development axis and establishment of rules on preservation - the practical use of various preservation methods and the standards suitable to the methods - laying down the standards of restoration according to the height from ground level - the application of zoning such as height district and urban design for preservation Finally, the design of implementation tools must be needed for protection and restoration.

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF