• Title/Summary/Keyword: Reynolds numbers

Search Result 639, Processing Time 0.028 seconds

Experimental investigation of flow parameters influencing the calibration of five-hole probes (5공프로우브의 보정에 영향을 주는 유동변수들에 대한 실험적 연구)

  • Lee, Sang-U;Yun, Tae-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.637-649
    • /
    • 1997
  • Effects of cone angle, pressure-hole orientation and Reynolds number on the five-hole probe calibration have been investigated for eight large-scale conical five-hole probes, which have either perpendicular pressure holes or forward-facing pressure holes for the cone angles of 45 deg, 60 deg, 75 deg and 90.deg. Pitch and yaw angles are changed from -40 deg to +40 deg with an interval of 5 deg, respectively, when the probe Reynolds numbers are 1.77*10$^{4}$, 3.53*10$^{4}$ and 7.06*10$^{4}$. The result shows that larger cone angle results in more sensitive changes in the calibration coefficients. In the case that the cone angle is 45 deg, the pitch-angle and yaw-angle coefficients of the five-hole probe with the perpendicular pressure holes show a very different trend compared with those of the five-hole probe with the forward-facing pressure holes. On the other hand, when the cone angle is more than 60 deg, each calibration coefficient is nearly independent of the pressure-hole orientation. Additionally, the effects of the Reynolds number on the calibration coefficients are also reported in detail.

A Study on the Visualization and Characteristics of Mixed Convection between Inclined Parallel Plates Filled with High Viscous Fluid (경사진 평행평판 내 고 점성유체의 혼합대류 열전달 특성 및 가시화에 관한 연구)

  • Piao, Ri-Long;Bae, Dae-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.698-706
    • /
    • 2006
  • Experiment and numerical calculation have been peformed to investigate mixed convection heat transfer between inclined parallel plates. Particle image velocimetry (PIV) with thermo-sensitive liquid crystal (TLC) tracers is used for visualizing and analysis. This method allows simultaneous measurement of velocity and temperature fields at a given instant of time. Quantitative data of the temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. The governing equations are discretized using the finite volume method. The results are presented for the Reynolds number ranges from 0.004 to 0.062, the angle of inclination, ${\Theta}$, from 0 to 45 degree and Prandtl number of the high viscosity fluid is 909. The results show velocity, temperature and mean Nusselt numbers distributions. It is found that the periodic flow of mixed convection between inclined parallel plates is shown at $0^{\circ}{\leq}{\Theta}<30^{\circ}$, Re<0.062, and the flow pattern can be classified into three patterns which depend on Reynolds number and the angle of inclination. The minimum Nusselt numbers occur at Re=0.05 regardless of the angle of inclination.

An Experimental Study on the Transitional Flows in a Concentric Annu- lus with Rotating Inner Cylinder (안쪽축이 회전하는 환형관내 천이유동에 관한 연구)

  • 김영주;김철수;황영규
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.299-305
    • /
    • 2002
  • The present experimental and numerical investigations are performed on the characteristics of transitional flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one rotating. The pressure losses and skin-friction coefficients have been measured for the fully devel-oped flow of water and that of 0.2% CMC-water solution at a inner cylinder rotational speed of 0∼600 rpm, respectively. The transitional flow has been examined by the measurement of pressure losses to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients. The occurrence of transition has been checked by the gradient changes of pressure losses and skin-friction coefficients with respect to the Reynolds numbers. The increasing rate of skin-friction coefficient due to the rotation is uniform for laminar flow regime, whereas it is suddenly reduced for transitional flow regime and, then, it is gradually decreased for turbulent flow regime.

Non-absorbable Gas Effects on Heat and Mass Transfer in Falling Film Absorption

  • Kim, Byongjoo;Lee, Chunkyu
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.581-589
    • /
    • 2003
  • Film absorption involves simultaneous heat and mass transfer in the gas-liquid system. While the non-absorbable gas does not participate directly In the absorption process. its pretence does affect the overall heat and mass transfer. An experimental study was performed to investigate the heat and mass transfer characteristics of LiBr-H$_2$O solution flow ing over 6-row horizontal tubes with the water vapor absorption in the pretence of non-absorbable gases. The volumetric concentration of non-absorbable gas, air, was varied from 0.17 to 10.0%. The combined effects of the solution flow rate and its concentration on the heat and mass transfer coefficients were also examined. The presence of 2% volumetric concentration of air resulted in a 25% reduction in the Nusselt number and 41% reduction in the Sherwood number Optimum film Reynolds number was found to exist at which the heat and mass transfer reach their maximum value independent of air contents. Reduced Nusselt and Sherwood numbers. defined as the ratio of Nusselt and Sherwood numbers at given non-absorbable gas content to that with pure water vapor, were correlated to account for the reduction in the heat and mass transfer due to non-absorbable gases in a falling film absorption process.

Application of Dispersion Number for Analysis of Tracer test in Sedimentation Basin (침전지 추적자 실험을 위한 Dispersion Number의 적용)

  • Kim, Young-Il;Park, No-Suk;Jung, Nam-Jung;Kim, Seong-Su;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.187-193
    • /
    • 2007
  • Reynolds and Froude numbers, along with tracer tests, have been widely used to estimate hydrodynamics in full-scale horizontal sedimentation basin in water treatment plants (WTPs). In spite of this, the former numbers do not reflect actual operating conditions, instead most often being based on the dimensions of the structures. The index and graphic analyses most often used were found to be too subjective to accurately analyze tracer test results. In order to overcome these limitations, dispersion number was applied for analysis of tracer test results. Tracer tests were conducted in eight full-scale sedimentation basins in six WTPs, and then analyzed by index and graphic analyses as well as by dispersion number. The dispersion number was more useful as an indicator of the hydrodynamic behavior in the basin. It was also found that as dispersion number decreased, flow approached the ideal for plug flow in which case, higher sedimentation efficiency could be expected.

The Improvement of the Heat Exchanger Performance by Shape Modifieation(II) (형상변화 에 의한 열교환기 의 열전달 성능 향상 (II))

  • 노승탁;이택식;강신형;이은현;송명호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.202-212
    • /
    • 1985
  • Numerical and experimental studies are presented for turbulent flows and heat transfer in annular channel with circumferential fins on the inner tube in a double pipe heat exchanger. Flow and heat transfer characteristics are periodically fully developed, and complex flow patterns are shown. Numerical calculations are executed by using modified TEACH-2E computer program based on the standard k-.epsilon. turbulence model. Mean velocity, turbulent kinetic energy, and Reynolds stress distributions are measured with the hot wire anemometer. Static pressures on the outer wall of the pipe are measured for three pitch-height ratios and several Reynolds numbers. Numerical predictions generally show reasonable results in comparison with experimental results. When the pitch-height ratio is about 5.0 and other geometric parameters are fixed in this paper, maximum heat transfer is achieved. Reattaching flow patterns appeared in this region. As the pitch between fins is increased beyond 5.0, mean Nusselt numbers are decreased and the pressure drop through one pitch almost remains.

Cavity as a New Passive Device for Reduction of Skin Friction and Heat Transfer (새로운 수동제어소자인 공동을 이용한 마찰력과 열전달 감소에 관한 연구)

  • Hahn Seonghyeon;Choi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.463-466
    • /
    • 2002
  • In order to examine the possibility of using a cavity as a passive device for reduction of skin friction and heat transfer, an intensive parametric study over a broad range of the cavity depth and length at different Reynolds numbers is performed for both laminar and turbulent boundary layers in the present study. Direct and large eddy simulation techniques are used for turbulent boundary layers at low and moderate Reynolds numbers, respectively. for both laminar and turbulent boundary layers over a cavity, a flow oscillation occurs due to the shear layer instability when the cavity depth and length are sufficiently large and it plays an important role in the determination of drag and heat-transfer increase or decrease. For a cavity sufficiently small to suppress the flow oscillation, both the total drag and heat transfer are reduced. Therefore, the applicability of a cavity as a passive device for reduction of drag and heat transfer is fully confirmed in the present study. Scaling based on the wall shear rate of the incoming boundary layer is also proposed and it is found to be valid in steady flow over a cavity.

  • PDF

A Study on Turbulent Characteristics of Turbulent Pulsating Flows in a Square Duct (4각 덕트내에서 난류 맥동유동의 난류특성에 관한 연구)

  • Park, G.M.;Go, Y.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.188-198
    • /
    • 1990
  • Turbulent characteristics of turbulent pulsating flows were studied experimentally in a square duct. Velocity waveforms, velocity profiles, and turbulent intensity of turbulent pulsating flow were investigated by using a hot-wire anemometer with data acquisition and a processing system in a square duct with a ratio of 1 ($40mm{\times}40mm$) to 4,000mm long. Turbulent components were shown to be larger in decelerating than in accelerating regions and also larger for a large phase of velocity and U'rms distribution of turbulent flow. The effect of velocity amplitude ratio does not exist for specified time [${\theta}(z^{\prime})$], amplitude ratio (${\mid}U^{\prime}_{rms.os.1}{\mid}/{\mid}U_{m.os.1}{\mid}$), and phase difference (${\Delta}U^{\prime}_{rms.os.1}-{\Delta}U_{m.os.1}$) in either turbulent oscillating or cross-sectional mean velocity components. The effect of dimensionless angular frequency for specified time [${\theta}(z^{\prime})$] can be disregarded because the dimensionless angular frequency does not affect the specified time. The velocity distributions of turbulent pulsating flows for various time-averaged Reynolds numbers are in approximate agreement with the velocity distributions for equivalent Reynolds numbers and 1/7th power law of steady flow.

  • PDF

A Study on the Heat Transfer of In-line Heat Exchanger (직렬 열교환기의 열전달에 관한 연구)

  • Choe, S.Y.;Kim, M.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.5
    • /
    • pp.48-53
    • /
    • 2008
  • Heat exchangers are commonly used in practice in a wide range of application, from heating and air-conditioning system in a household, to chemical processing and power production in a large plant. Heat transfer in a heat exchanger usually involves convection in each fluid and conduction through the wall separating the two fluids. The heat transfer characteristics of tube banks of in-line arrangements of four circular cylinders in a cross flow are compared for a range of tube locations and Reynolds numbers. The in-line pitch ratio was set up in the range of $1.5\leq L/d\leq4.0$, where L is the center to center distance and d the circular cylinder diameter, and in the Reynolds number of $13,000\leq Re\leq50,000$. The local and mean Nusselt numbers were estimated, and then. Subsequently, the heat transfer characteristics of four circular cylinders were found to exhibit a strong dependency upon the cylinder spacing and separation point of their upstream cylinders.

  • PDF

Wind Turbine Airfoils considering Surface Roughness Effects (표면거칠기 둔감도를 고려한 풍력발전기용 익형 개발)

  • Kim, Seok-Woo;Shin, Hyung-Ki;Jang, Moon-Seok
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.36-44
    • /
    • 2007
  • Most airfoils for wind turbines commercially available have been developed for aircrafts, which are operated at high Reynolds numbers. However, Reynolds numbers of wind turbines are very low compared to those of aircrafts. In other to improve wind turbine performances, airfoils for the use of wind turbine shall be designed such as S-series airfoils developed by NREL in America. The authors have designed new airfoils for wind turbines considering designated operation conditions of wind turbines and even local wind resources in Korea. The designed airfoils are characterized by improved roughness insensitivities compared to other airfoils such as S814 and S820. The developed KWA005-240 and KWA009-127 are for root and tip sections of a wind turbine blade, respectively. Although the results show much improved performances against NACA airfoils, performance data of post-stall regulation loses some accuracies due to the characteristics of the simulation tool of XFOIL. Therefore, wind tunnel experiments are required for more accurate evaluation of the designed airfoils. Currently, the experiments has been completed and the data analysis works are going on now. The final results obtained from the experiments will be published soon.

  • PDF