• Title/Summary/Keyword: Reverse-osmosis

Search Result 418, Processing Time 0.028 seconds

Performance evaluation of forward osmosis (FO) hollow fiber module with various operating conditions (중공사막 모듈을 이용한 정삼투 공정에서의 운영조건 변화에 따른 성능평가)

  • Kim, Bongchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.357-361
    • /
    • 2018
  • Forward osmosis (FO) process has been attracting attention for its potential applications such as industrial wastewater treatment, wastewater reclamation and seawater desalination. Particularly, in terms of fouling reversibility and operating energy consumption, the FO process is assumed to be preferable to the reverse osmosis (RO) process. Despite these advantages, there is a difficulty in the empirical step due to the lack of separation and recovery techniques of the draw solution. Therefore, rather than using FO alone, recent developments of the FO process have adapted a hybrid system without draw solution separation/recovery systems, such as the FO-RO osmotic dilution system. In this study, we investigated the performance of the hollow fiber FO module according to various operating conditions. The change of permeate flow rate according to the flow rates of the draw and feed solutions in the process operation is a factor that increases the permeate flow rate, one of the performance factors in the positive osmosis process. Our results reveal that flow rates of draw and feed solutions affect the membrane performance, such as the water flux and the reverse solute flux. Moreover, use of hydraulic pressure on the feed side was shown to yield slightly higher flux than the case without applied pressure. Thus, optimizing the operating conditions is important in the hollow fiber FO system.

Electrospun polyamide thin film composite forward osmosis membrane: Influencing factors affecting structural parameter

  • Ghadiri, Leila;Bozorg, Ali;Shakeri, Alireza
    • Membrane and Water Treatment
    • /
    • v.10 no.6
    • /
    • pp.417-429
    • /
    • 2019
  • Poly Sulfone nanofibers were electrospun to fabricate membranes of different characteristics. To fabricate the fiber mats, polymer concentration, flowrate, and current density were determined as the most influencing factors affecting the overall performance of the membranes and studied through Response Surface Methodology. The Box-Behnken Design method (three factors at three levels) was used to design, analyze, and optimize the parameters to achieve the best possible performance of the electrospun membranes in forward osmosis process. Also, internal concentration polarization that characterizes the efficiency of the forward osmosis membranes was determined to better assess the overall performance of the fabricated electrospun membranes. Water flux to reverse salt flux was considered as the main response to assess the performance of the membranes. As confirmed experimentally, best membrane performance with the minimal structural parameter value could be achieved when predicted optimal values were used to fabricate the membranes through electrospinning process.

Characteristics of Reverse Flux by using Direct Omosis in RO Membrane Process (역삼투막 공정에서 Direct Osmosis의 역방향 Flux 기초특성)

  • Kang, Il-Mo;Dock-Ko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.399-405
    • /
    • 2011
  • In a desalination technology using RO membranes, chemical cleaning makes damage for membrane surface and membrane life be shortened. In this research cleaning technology using direct osmosis (DO) was introduced to apply it under the condition of high pH and high concentration of feed. When the high concentration of feed is injected to the concentrate side after release of operating pressure, then backward flow occurred from treated water toward concentrated for osmotic pressure. This flow reduces fouling on the membrane surface. Namely, flux of DO was monitored under pH 3, 5, 10 and 12 conditions at feed concentrations of NaCl 40,000 mg/L, 120,000 mg/L and 160,000 mg/L. As a result, DO flux in pH 12 increased about 21% than pH 3. DO cleaning was performed under the concentrate NaCl 160,000 mg/L of pH 12 during 20 minutes. Three kinds of synthetic feed water were used as concentrates. They consisted of organic, inorganic and seawater; chemicals of SiO2 (200 mg/L), humic acid (50 mg/L) sodium alginate (50 mg/L) and seawater. As a result, fluxes were recovered to 17% in organic fouling, 15% in inorganic fouling and 14% of seawater fouling after cleaning using DO under the condition of concentrate NaCl 160,000 mg/L of pH 12.

Investigation of Organic Fouling with AFM(Atomic Force Microscope) in Reverse Osmosis Membrane and Forward Osmosis Membrane (FO와 RO막에서 AFM(Atomic Force Microscope)을 이용한 유기 막 오염 연구)

  • Kuk, Ji-Hoon;Lee, Sang-Youp;Hong, Seung-Kwan
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.102.1-102.1
    • /
    • 2010
  • 대체수자원 중 막여과 기술에 대한 관심이 지속적으로 높아지고 있다. 하지만, 이러한 막여과 기술에는 fouling이 발생시 효율저감, flux저감, 소모에너지 증대 등 문제점이 발생한다. 이러한 fouling저감을 위해 막 표면특성분석을 통한 기초연구가 필요하다고 보고 이 연구를 진행하였다. AFM을 이용하여 CML입자와 막의 상호작용을 통해 초기 막오염 경향을 예측할 수 있다.

  • PDF

Pretreatment of Acrylic Wastewater and Application of UF/RO Processes (Acrylic폐수의 전처리 및 UF/RO공저의 적용)

  • 이광현
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2001.05a
    • /
    • pp.135-138
    • /
    • 2001
  • Acrylic wastewater flux was discussed using modules of ultrafiltration hollow fiber and reverse osmosis spiral wound. The optimum backflushing times of membranes were decided and the degree of fouling was discussed with operating time. Permeate flux was decreased rapidly at 12hrs. Separation processes with ultrafiltration and reverse osmosis membranes were not suitable to remove COD and TDS. The improvement of pretreatment processes was needed.

  • PDF

Removal of Silica and Humic Acid from Brackish Water with Calcite (Calcite를 이용한 brackish water 내의 실리카와 휴믹산의 제거에 관한 연구)

  • 박소희;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.243-245
    • /
    • 2002
  • Brackish water desalination using reverse osmosis(RO) membrane is more useful and economic than sea water to solve the shortage of fresh water supply because of its low total dissolved solid(TDS) contents. Silica and humic acid in brackish water make serious fouling problems and cause the decline of permeate flux and increase of operating pressure. In this study, the experiments for removal of silica and humic acid were conducted with calcite particles to prevent membrane fouling and investigated the effect of pH of feed water Adsorption of silica to calcite was higher at pH=7.5 than 9.5 and removal rate was increased according to increase of initial concentration of silica. The effect of pH on adsorption of humic acid was not significant but at low initial concentration the adsorption of humic acid was enhanced at pH 7.5. The result of this study expect to apply to brackish water desalination experiment of flat-sheet reverse osmosis membrane.

  • PDF

An Application of the Analytic Hierarchy Process to the Selection of the Membrane Systems of Waste Water Treatment (AHP를 이용한 폐수정화공정의 막기술 선정에 관한 연구)

  • Hong, Soon-Wook;Kim, Gang-Min;Kim, Tae-Hyun;Cho, Keun-Tae
    • IE interfaces
    • /
    • v.12 no.4
    • /
    • pp.602-616
    • /
    • 1999
  • Recently, due to the primary emphasis of environmental problem, the proper selection of the membrane systems necessary for waste water treatment has been one of the critical issues in the industrial sector. This paper shows how an Analytic Hierarchy Process (AHP) model can be used for assessing the performance of selected membrane systems: ultrafiltration, microfiltration, reverse osmosis, and electrodialysis essential for waste water treatments. The final results show that ultrafiltration is the most attractive membrane system to use in a water recycling system, followed by microfiltration, reverse osmosis and electrodialysis. This is consistent with the information that we found with respect to the elements that were taken into consideration. Sensitivity analysis is also provided here.

  • PDF

The Cost Reduction Effect of Gridable Sea Water Reverse Osmosis Desalination Plant (전력망 연동형 해수담수화 플랜트의 운영비용 절감효과)

  • Lee, Jong-Hyun;Choi, Jung-In;Bae, Si-Hwa;Ko, Won-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.64-69
    • /
    • 2011
  • A novel concept of the gridable desalination plant is to provide an operation management to enable an electricity plant operation cost reduction. Adjusting recovery rate responded to electricity price, an electricity plant operation cost can be saved. To show a suggested approach, the data of 10 [MIGD](Million Imperial Gallons per Day) SWRO testbed are used. The result shows that total cost reduction rate is calculated about 1.6[%] of annual total electric plant operation cost.

Evaluation of Oil Pollutants Removal in Seawater as Pretreatment Process for Reverse Osmosis Desalination Process (역삼투식 해수담수화의 전처리공정으로서 유분 제거의 평가)

  • ;Okada Mitsumasa
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.205-209
    • /
    • 2003
  • The various pretreatment processes were evaluated for removal of oil pollutants with weathered oil contaminated seawater in a reverse osmosis desalination process. Weathered oil contaminated seawater was made by biodegradation and photooxidation with oil containing seawater. Coagulation, ultrafiltration, advanced oxidation processes and granular activated carbon filtration was used with pretreatment for dissolved organic carbon. Crude oil was removed but. weathered oil contaminated seawater was not removed by biodegradation and coagulation. DOC and E260 was removed with about 20 % and 40 % by membrane filter of cut off molecular weight 500. So, the most of dissolved organic carbon in weathered oil contaminated seawater was revealed that molecular weight was lower than 500. It is difficult to remove DOC in weathered oil contaminated seawater by advanced oxidation processes treatment, but, E260 was removed more high. However, DOC in weathered oil contaminated seawater was easily adsorbed to GAC. It is revealed that DOC was removed by adsorption.

  • PDF

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.