• 제목/요약/키워드: Reverse Torque

검색결과 71건 처리시간 0.028초

접촉상태에 있는 초정밀 역전방지클러치의 내구성 평가에 관한 연구 (A Study on Endurance Estimation of ultra Precision Reverse-Locking Clutches under Contact Condition)

  • 서정세;이석순;이태선;최중환;이상범
    • 한국정밀공학회지
    • /
    • 제22권6호
    • /
    • pp.47-54
    • /
    • 2005
  • A dangerous event occurred at the field industry and mechanical system. At developed by SUNGGOKNANOTECH corp. a R-L clutches of a small and high capacity serves safety device from a variety environment of mechanical system, it permits transmission of driving torque from input to output shaft in both directions of rotation, but restrains any feedback torque of the driven load from rotating the output shaft in either direction. This study was carried out to demonstrate through finite element method and durability estimation for safety of the R-L clutches without sliding during the engagement process. As results, we organized about endurance test method when applied rated torque.

Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions

  • Mostafavi, Azam Sadat;Memarian, Maryam;Seddigh, Mohammad Ali
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.65-70
    • /
    • 2021
  • Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with one-way ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.

성견에 식립한 인산칼슘 피복 임플란트가 골조직 유착에 미치는 생물학적인 영향 (The Biological Effects of Calcium Phosphate Coated Implant for Osseointegration in Beagle Dogs)

  • 심언철;임성빈;정진형;김종여
    • Journal of Periodontal and Implant Science
    • /
    • 제33권4호
    • /
    • pp.651-671
    • /
    • 2003
  • The influence of calcium phosphate (Ca-P) coating on the bone response of titanium implants was investigated two types of titanium implants, i.e. as -machined ,as -machined with Ca-P coating, were prepared. The Ca-P coating produced by OCT Inc technique. These implants were inserted into the left and right femur of beagle dog, After implantation periods of 3 days, 1weeks, weeks, 4weeks, 8weeks, 12weeks. 24weeks, the bone-implant interface was evaluated histologically, histomorphometrically , and removal torque. Histological evaluation revealed no new bone formation around different implant materials after 2weeks of implantation. After 4 weeks, Ca-P coated implants showed a higher amount of bone contact than either of the non coated implants. After 12weeks, bone healing was almost completed. And implant were removed by reverse torque rotation with torque-measuring device. Mean torque values for 4weeks control were 2.375Kgf.cm and experimental were 2.725Kgf.cm. And mean torque values for 8weeks control were 1.25Kgf.cm and experimental were 1.0Kgf.cm On the basis of these findings, we concluded that deposition of a Ca-P coating on an implant has a beneficial effect on the bone response to this implant during the healing phase. Besides implant surface conditions the bone response is also determined by local implant site condition.

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

리타더 장착 버스 하이포이드 기어의 스코링에 관한 연구 (Study on Scoring of Hypoid Gear Set in Bus with Retarder)

  • 양정호;김용조
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.102-109
    • /
    • 2009
  • A retarder, as a supplementary brake system that is not friction-based, is frequently used in heavy-duty vehicles generally to slow the vehicles down on inclines. The electric retarder mainly used in a heavy-duty bus is generally placed between the transmission and the axle. The rotor inside the retarder system is attached to the axle. The operation of the retarder within a driven vehicle generates reverse torque due to coast driving force on hypoid gears in the differential gear system. By the reverse torque, scoring or scuffing on the hypoid gear teeth may directly occur. The scoring may be generated due to excessive contact stresses on the tooth surface. In this study, tooth contact stresses and contact patterns were analysed in order to investigate on the tooth scoring phenomenon using a finite element analysis program T900 in which the Hertzian contact stress formula was taken. Backlash, wear and surface finish were considered in the finite element simulation on the scoring.

  • PDF

저속 고토크 가혹감속기의 저비용 테스트 시스템 개발에 관한 연구 (A Study on the Low Cost Testing System Development of the Low Speed and High Torque Harsh Reducer)

  • 박태현
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.379-386
    • /
    • 2022
  • The goal of this research is to verify a performance test system for a low speed, high torque, and harsh reducer at low cost. The reducer rotates a cooling fan with a diameter of 10 meters, in a high temperature (50℃) cooling tower in a geothermal power plant. It requires about 500 kgf·m torque and 47.75 kW power to rotate the fan at a maximum power condition. An expensive dynamometer is commonly used for performance test of a motor or a reducer. In this paper, a low cost system is developed using a hydraulic pump as a load unit to generate torque instead of a dynamometer. We accurately calculated the required power, the flow meter, and the pressure of the pump, and selected to design and optimize the system at minimal cost. The system also applied another reverse reducer and a gearbox to increase the rotational speed and to reduce the torque from the low speed and high torque target reducer. This allows low-cost systems to be built using inexpensive components. The developed system was able to successfully measure the high torque and the low rotational speed of the target reducer at high temperature.

역설계 기반의 전기자동차 스티어링 기어박스 개발 (Development of the Steering Gear Box for Electric Vehicles based on the Reverse Engineering)

  • 문성식;유영민;유우식
    • 산업공학
    • /
    • 제25권1호
    • /
    • pp.134-141
    • /
    • 2012
  • The steering gear box for mid-heavy duty electric vehicles are usually produced by only a few specialized companies. The special techniques, such as designing, producing and testing technology have been veiled. For this reason, steering gear boxes are imported from other country. The durability test with the electric vehicle which is satisfies the design parameters takes several years, and a prototype is installed in the real vehicle for the test. In this research, the steering gear box of the steering system was developed based on the reverse engineering and the testing methods and the steering gear box development process have been suggested. The prototype is also developed with the CAD and CAE tools. Developed steering gear box have been tested in torque tester and have satisfied requied torque. As a result, the process and testing methods studied in this research are useful in the development processes of electric vehicles steering system.

원통캠 형상에 따른 틸팅식 풍력터빈의 성능에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Tilting-Type Wind Turbine According to Cylindrical Cam Shape)

  • 유환석;성재용
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.23-32
    • /
    • 2021
  • Conventional wind power generators have limited installation sites due to low efficiency due to reverse resistance or high cut-in speed. To compensate for these problems, this study proposed another new type of tilting wind turbine. The key to this method is the structural design of a cylindrical cam with a guide groove that allows the blade to tilt. As the blade rotates by the cam, it tilts according to the angle. In the section that generates torque by receiving drag, the blade is made perpendicular to the wind. And it is a structure that creates a parallel state with the wind in the section where reverse resistance occurs. We prepared six types of cams considering the length of the section subject to drag, reverse resistance, tilting section. The performance was analyzed as the maximum value of the output, torque coefficient, and efficiency coefficient, which is indicated by setting different wind speed and low TSR.

고속도 BLDC 전동기의 토크 향상을 위한 개선된 전류 저어 방법 (An Improved Current Control Method for Torque Improvement of High Speed BLDC Motor)

  • 박성인;김태성;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.115-118
    • /
    • 2002
  • In this paper, a current control method using adjustment of the phase advance angle is proposed. This proposed method improves the torque and speed response characteristic by minizing delay of current at high speed operation, and also make reverse motoring possible. Simulated results prove the effectiveness of the propposed method through comparison with the conventional unipolar PWM method.

  • PDF

아킬레스 건 파열의 봉합 후 발생한 심부 감염의 치료 (Treatment of Deep Infection Following Repair of Achilles Tendon Rupture)

  • 이우천;김유미;고한석
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.168-172
    • /
    • 2006
  • Purpose: Theaim of this study was to review the results of treatment for deep infection following repair of Achilles tendon rupture using reverse sural arterialized flap and/or flexor hallucis longus transfer. Materials and Methods: Five cases of Achilles tendon infection in five patients were treated using reverse sural arterialized flap and/or flexor hallucis longus transfer at our hospital with followed up of average 23.6 months (range, 13-43 months). Three patients were male and average age at surgery was 52.0 years (range, 42-59 years). Clinical results were evaluated by the method of Percy and Conochie, and the isokinetic peak torque value was interpreted according to the guideline of Sapega. Results: The clinical result was excellent in three cases, good in one case and fair in one case. The isometric peak torque value for $30^{\circ}$ per second was normal in two cases, possibly abnormal in one case, and probably abnormal in two cases, and for $120^{\circ}$, normal in one case, probably abnormal in four cases. Five cases in five patients were satisfied with the result of treatment. Conclusion: We can expect satisfactory results of treatment for deep infection following repair of Achilles tendon rupture using reverse sural arterialized flap and/or flexor hallucis longus transfer.

  • PDF