The influence of calcium phosphate (Ca-P) coating on the bone response of titanium implants was investigated two types of titanium implants, i.e. as -machined ,as -machined with Ca-P coating, were prepared. The Ca-P coating produced by OCT Inc technique. These implants were inserted into the left and right femur of beagle dog, After implantation periods of 3 days, 1weeks, weeks, 4weeks, 8weeks, 12weeks. 24weeks, the bone-implant interface was evaluated histologically, histomorphometrically , and removal torque. Histological evaluation revealed no new bone formation around different implant materials after 2weeks of implantation. After 4 weeks, Ca-P coated implants showed a higher amount of bone contact than either of the non coated implants. After 12weeks, bone healing was almost completed. And implant were removed by reverse torque rotation with torque-measuring device. Mean torque values for 4weeks control were 2.375Kgf.cm and experimental were 2.725Kgf.cm. And mean torque values for 8weeks control were 1.25Kgf.cm and experimental were 1.0Kgf.cm On the basis of these findings, we concluded that deposition of a Ca-P coating on an implant has a beneficial effect on the bone response to this implant during the healing phase. Besides implant surface conditions the bone response is also determined by local implant site condition.
Keywords
Ca-P coated implant; new bone formation; reverse torque; bone response;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Natiella JR, Armitage JE, Greene GW, Meenaghan HA: Current evaluationof dental implant. Council on dental materials and devices. J Am Dent Assoc. 84:1359-1373,1972
2 Robers E: Bone tissue interface. J Dent Educ. 52: 804-809,1988
3 Albrektsson, T., 'Intra-osseous anchourage of dental implants', J. Prostht. Dent., 50: 255-261,1983   DOI   PUBMED   ScienceOn
4 Steflik DE, Parr GR, Sisk AL, Lake FT et al. Osteoblast activity at the dental implant-bone interface: Transmission eclectron microscopic and high voltage electron microscopic observations. J periodontol .65:404-413,1994   DOI   ScienceOn
5 Kasemo B, Lausmaa J. Biomaterial and implant surfaces: A surface science approach. Int J Oral Maxillofacial Implants. 3:247-259,1988
6 Taborelli M, Jobin M, Francois P,Vaudaux P, Tonerri Szmukler-Moncler S, Simpson P, Descouts P. Influence of surface treatments developed for oral implants on the physical and biologicalproperties of titanium. (1)Surface characterization. Clin Oral Impl Res. 8:208-216, 1997.   DOI   ScienceOn
7 Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Removal torques for polished and rough titanium implants. Int J Oral Maxillifac Implants. 1988;3:21-24
8 Deporter DA, Watson PA, Pilliar RM, Chipman ML, Valiquette N, A histological comparison in the dog of porous-coated vs. threaded dental implants. J Dent Res. 69:1138-1145,1990   DOI   ScienceOn
9 Gottlander M, Albrektsson T. Histomorphometric analyses of hydoxylapatite-coated and uncoated titanium implants. The importance of implant design. Clin Oral Implants Res. 3:71-76,1992   DOI   ScienceOn
10 Matsui Y, Ohno K, Michi K, Yamagata K. Experimental study of high velocity flame-sprayed hydroxyapatite coated and noncoated implants. Int J Oral Maxillofac Implants. 1994;9:397-404
11 Steflik D, McKinney R, Ultrastrustural comparisons of ceramic and titanium dental implants in vivo: A scanning electron microscopic study. J Biomed Mater Res. 1989;23:895-909
12 Thomas K, Cook S. An evaluation of variables influencing implants fixation by direct bone apposition. J Biomed Mater Res. 1985;19:875-901   DOI   ScienceOn
13 Wennerberg A, Albrektsson T, Andersson B, Krol J. A histomorphmetric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res. 1995;6:24-30   DOI   ScienceOn
14 Weinlaender M, Kenney EB, Lekobic V, Moy PK: Histomorphometry of bone apposition around tree types of osseous dental implants: Int J Oral Maxillofac Implants. 7:491-496,1992
15 Caulier, H., van der Waerden,J.P.C.M., Paquay, Y.C.G.J., Wolke, J.G.C., Kalk, W., Naert, I. & Jansen, J.A. (1995) The effect of calciumphosphate (Ca-P) coatings on trabecular bone response: a histological study. J Biomed Mater Res. 29: 1061-1069
16 Ducheyne, P., Radin, S. & King, L.(1993) The effect of calcium phosphate ceramics composition and structure on in vitro behavior. I. Dissolution. J Biomed Mater Res. 27: 25-34
17 Wolke,J.G.C.,van Dijk, K., Schaeken, H.G., de Groot, K. & Jansen. J.A. (1994) Study of the surface characteristics of magnetron-sputter calcium phosphate coatings. J Biomed Mater Res. 28: 1477-1484
18 Hayakawa T, Yoshinari M, Nemoto K, Wolke JGC, Jansen JA. Effect of surface roughness and calcium phosphate eating on the implant/bone response. Clin Oral Implants Res 11:296-304, 2000
19 Vercaigne S, Wolke JGC, Naert Jansen JA. A histological evaluation of TiO2-gritblasted and Ca-P magnetron Sputter coated implants placed into the Trabecular bone of the goat: part2. Clin Oral Implants Res. 11:314-324, 2000
20 Sennerby L, Thomesen P, Ericson LE: A morphologic and Biomechanic Comparison of Titanium implants in rabbit cortical and cancellous bone. Int. J Oral Maxillofac Implants 7:62-71, 1992
21 Bhaskar SN, Cutright DE, Knapp MJ, Beasley JD, Perez B, Driskell TD. Tissue reaction to intrabony ceramic implants. Oral Surg Oral Med Oral Path. 1971;31:282   DOI   ScienceOn
22 Cheang, P. & Khor, K.A. (1996) Addressing processing problems associated with plasma spraying of hydroxyapatite coatings. Biomaterials 17:537-544   DOI   ScienceOn
23 Wolke,J.G.C. de Groot, K & Jansen, J.A. (1998) In vivo dissolution behavior of various RF magnetron sputtered Ca-P coating. J Biomed Mater Res. 39:524-530
24 Cui FZ, Luo ZS, Feng QL. Highly adhesive hydroxyapatite coatings on titanium alloy formed by ion beam assisted deposition. J Mater Sei: Mater Med 1997;8:403-5
25 Dhert, W.J.A., Klein, C.P.A.T., Jansen,J.A., van der Velde, E.A., Vriesde, R.C., Rozing, P.M.& de Groot, K. (1993) A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite and hydroxyapatite plasmasprayed coatings in goats. J Biomed Mater Res. 27:127-138
26 Cook S, Kay J, Thomas K, Jarcho M interface mechanics and histology of titanium and hydroxy-lapatite-coated titanium for dental implant applications. Int J Oral Maxillofac Implants. 2;15-22.1987   PUBMED
27 Branemark PI, Breine U, Johasson B, Roylance PJ, Rockert H, Yoffey JM: Regeneration of bone marrow. A clinical and experimental study following removal of bonemarrow by curettage.Acta Anat. 59:1-46,1964   DOI
28 Gotfredsen K, Rostrup E, Hhorting-Hansson E, Stoltze K, Budtz-Jorgensen E. Histological and histomorphometrical evaluation of tissue reactions adjacent endosteal implants in monkeys. Clin Oral Implants Res. 1991;2:30-37   DOI   ScienceOn
29 Buser D, Schenk RK, Stinemann S, Fiorelini JP, Fox CH, Stich H: Influence of surface charateristics on bone integration titanium implants, A histomorphometric study in miniature pigs. J Biomed Mater Res. 25:880-902,1991
30 Campbell AA, Fryxell GE, Linehau JC, Graff GL. Surface-in-duced mineralization: a new method for producing calcium phosphate coatings. J Biomed Mater Res 1996;32:111-8   DOI   ScienceOn
31 Wennerberg, A., Alberktsson, T., Johnansson, C. & Andersson, B. (1996a) Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effect of blasting material and surface topography. Biomaterials 17:15-22   DOI   ScienceOn
32 Caulier, H., Vercaigne, S., Naert, I., van der Waerden, J.P.C.M., Wolke, J.G.C., Kalk, W.& Jansen,J.A. (1997a) The effect of Ca-P plasmasprayed coatings on the initial bone healing of oral implants; an experimental study in the goat. J Biomed Mater Res. 34:121-128
33 Climens, J.A.M.(1995) Fluorapatite coatings for the osseointegration of orthopaedic implants. Thesis, University of Leiden, The Netherlands
34 Cheng Yang, Wuhan, The effect of calcium phosphate implant coating on osteoconduction. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001;92:606-9
35 Johansson CB, Albrektsson T. A removal torque and histomorphometric study of commercially pure niobium and titanuim implants in rabbit bone. Clin Oral Implants Res. 1991;2:24-29   DOI   ScienceOn
36 Branemark PI: Introduction to osseointegration. In Branemark PI, Zarb GA, Albrektsson T(eds): Tissue integrated prosthesis. Osseointegration in clinical dentistry. Chicago, Quintessence Publishing Co., pp11-76,1985
37 Gotfredsen K, WennerbergA, Johansson C, Skovgaard LT, Hjorting-Hansen E. Anchorage of TiO2-blasted HA-coated, and machined implants: An experimental study with rabbits. J Biomed Mater Res. 29:1223-1231,1995   DOI   ScienceOn
38 Meffert R, Block M, Kent J. What is osseointegration? Int J Periodontics Restorative Dent. 1987;7(4):9-21
39 Jansen JA, van de Waerden J, Wolke J, de Groot K. Histologic evalustion of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res. 1991;25:973-989   DOI   PUBMED
40 Deporter DA, Watson PA, Pilliar RM: A histological assessment of the initial healing response adjacent to porous-surface, titanium alloy dental implant system in dogs. J Dent Res. 65:1064-1070, 1986   DOI   ScienceOn
41 Wennerberg, A., Alberktsson, T. & Lausmaa, J. (1996b) Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25-and 75-${\mu}m$-sized particles of Al203. J Biomed Mater Res. 30:251-260.   DOI
42 van dijk, K., Schaeken, H.G., Wolke,J.G.C & Jansen, J.A. (1996) Influence of annealing kemperature on RF magnetron sputtered calcium phosphate coatings. Biomaterials 17:405-410   DOI   ScienceOn
43 Van Dijk, K., Schaeken, H.G. Wolke, J.G.C., Maree, C.H.M., Habraken, F.H.P.M., Verhoeven, J.& Jansen, J.A.(1995) Influence of discharge power level on the properties of hydroxyapatite films deposited on Ti6A14V with RF magnetron sputtering. J Biomed Mater Res. 29:269-276
44 Cotell CM. Pulsed laser deposition and processing of biocompatible hydoxylapatite thin films. Appl Surf Sci 1993;69:140-8   DOI   ScienceOn
45 Wennerberg, A., Alberktsson, T. Andersson, B & Krol, J.J. (1995b) A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clinical Oral Implants Research 6:24-30   DOI   ScienceOn
46 Wong, M., Eulenberger. J., Schenk, R. & Hunziker, E. (1995) Effect of surface topology on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res. 29(12):1567-1575
47 Hahn H, Palich W: Preliminary evaluation of porous metal surfaced titanium for orthopedic implants. J Biomed Mater Res. 4:571-577,1970
48 Adell R, Lekholm U,Rockler B, Branemark PI: A 15-year study of Osseointergrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 10:387-416,1981   DOI
49 Buser D, Weber HP, Lang NP: Tissue integration of a longitudinal study with ITI hollow-screw and hollow cylinder implants. Clin Oral Imp Res. 1: 33-40,1990   DOI   ScienceOn
50 Zueiqat H, Howlett CR. Titanium substrata composition influences osteoblastic phenotype: Invitro study. J Biomed Mater Res. 47:360-366,1999   DOI   ScienceOn
51 Wilke HJ, Class L, Steinemann S. The influence of various titanuim surfaces on the interface shear strength between implants and bone. In: Heimke G, Soltesz U, Lee AJC, eds. Advances in Biomaterials. vol. 9, Clinical Implant Materials. Amsterdam: Elsevier Science Publishers B.V.; 1990:309-314
52 Jansen, J.A., de Groot, K. (1993b) Application of magnetron sputtering for producing ceramic coatings on implant materials. Clinical Oral Implants Research 4:28-34   DOI   ScienceOn
53 Wolke, J.G.C., van der Waerden, J.P.C.M., de Groot, K. & Jansen, J.A. (1997) Stability of radiofrequency magnetron sputtered calcium phosphate coatings under cyclically loaded condition. Biomaterial. 18:483-488
54 Hulshoff, J.E.G., Hayakawa, T., van Dijk, K., Leijdekkers-Govers, A.F.M., van der Waerden, J,P.C.M. & Jansen, J.A.(1997) Mechanical and histological evaluation of Ca-P plasma-spray and magnetron sputter-coated implant' in trabecular bone of the goat'. J Biomed Mater Res. 36:75-83
55 Ducheyne P, Radin S, Heughebaert M, Heughebaert JC. Calcium phosphate ceramic coatings on porous titaniun: effect of structure and composition on edectrophoretic deposition, vacuum sintering and in vitro dissolution. Biomaterials 1990;11:244-54   DOI   ScienceOn
56 Cook S, Baffes G, Palafox A, Wolfe M, Burgess A. Torsional stability of HA-coated and grit-blasted titanium dintal implants. J Oral Implantol. 18:354-358,1992
57 Linkow LI: Endoosseous oral implantology: A 7-year progress report. Dent Clin North Am. 14: 185-200, 1970   PUBMED
58 Albrektsson T, Dahl E, Enbom L: Osseointegrated oral implants. A swedish multicenter study of 8139 consecutively inserted nobelpharma implants. J Peridontol. 59:287-296, 1988   DOI
59 Maggiolo. : 'Le manual de I art du dentiste, Nancy,1807. in Lew. I.: progress in implant dentistry- an elevation'. J. Am. Dent. Assoc. 59:478-492,1959   DOI
60 Babbush CA, Kent JN, Misiekm DJ Titanium plasma sprayed(TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg. 44:274-282,1986   DOI   ScienceOn
61 Albee FH, Morrison HF. Studies in bone growth-Triple calcium phosphate as a stimulus to osteo-genesis. Ann Surg, 1920;71:32-9
62 Jansen,J.A., van der Waerden,J.P.C.M., Wolke, J.G.C. & de Groot, K.(1991)Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res. 25: 973-989
63 Wennerberg, A., Alberktsson, T. & Andersson, B. (1995a) Ananimal study of c.p, titanium screws with different surface topographies. J Mater Sci: Materials in Medicine 6:302-309
64 Albrektsson, T: Osseointegrated titanium implants. Acta Orthop Scand. 52:155-170,1981   DOI
65 Gottlander M, Albektsson T, Carlsson L. Ahistomorphometric study of unthreaded hydroxyapatite-coated and titanium-coated implants in rabbit bone Int J Oral Maxillofac Implants. 1992;7:485-490
66 Nanci A, Wuest JD, Peru L,Brunet P,Shama V,Z Alzal S, Mckee MD. Chemical modificationof titanium surface s for covalent attachment of biologicalmolecules. J Biomed Mater Res 40:324-335,1998   DOI   ScienceOn
67 Cook S, Salkeid S, Gaisser D, Wagner W. The effect of surface macrotexture on the mechanical and histologic characteristics of hydroxylapatite-coated dental implants. J Oral Implantol. 14:288-294,1993
68 Buser D, Schenk RK, Steinmenn S, Fiorellini JP, Fox CH, Stich H, Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res. 1991;25:889-992   DOI   PUBMED
69 Albrektsson, T., Jansson,T., and Lekholm, U. :'Osseointegrated dental implants, Dent. Clin. North. Am. 30: 151-174, 1986   PUBMED
70 Ericsson I, Johansson CB, Bystedt H, Norton MR, A histomorphometric evaluation of bone-tobone implant contact on machine-prepared and roughened titanium dental implants: A pilot study in the dog. Clin Oral Implants Res. 5:202-206,1994   DOI   ScienceOn
71 Steinmann SG, Eulenberger J,Mausli PA, Schroeder A: Adhesion of bone to titanium. Advance in Biomaterials Vol 6. Amsterdam, Biological and AJC Lee Elsevier Science Publishers,.pp409-414,1986
72 Kangasniemi. I.M.O.., Verheyen, C.C.P.M., van der Velde, E.A. & de Groot, K.(1994) In vivo tensile testing of fluorapatite and hydroxylapatite plasma-sprayed coatings. J Biomed Mater Res. 28: 563-572
73 Klein, C.P.A.T., Wolke, .J.G.C., de Blieck-Hogervost, J.M.A. & de Groot, K.A. (1994a) Calcium phosphate plasma-sprayes coatings and their stability: An in vivo study. J Biomed Mater Res. 28:909-917
74 Jansen, J.A., van der Waerden, J.P.C.M. & Wolke J.G.C.(1993a) Histologic investigation of the bioligical bahavior of different hydroxyapatite plasma-sprayed coatings in rabbits. J Biomed Mater Res. 27:603-610
75 Kim HM, Miyaji F, Kokubo T, Nakamura T. Bonding stregth of bonelike apatite layer on Ti metal substrate. J Biomed Mater Res (Appl Biomater) 1997;38:121-7   DOI   ScienceOn
76 Gottlander M, Albrektsson T. Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants. 1991:6:399-404
77 Caulier, H.,van der Waerden, J.P.C.M., Wolke, J.G.C., Kalle, W., Naert, I. & Jansen,J.A. (1997b) A histological and histomorphometrical evaluation of the application of screw designed calciumphosphate(Ca-P) coated implants in the cancellous maxillary bone of the goat. J Biomed Mater Res. 35:19-30