• Title/Summary/Keyword: Reverse Osmotic Membrane

Search Result 29, Processing Time 0.024 seconds

A Study on the Ethanol Concentration by Osmotic Sink Reverse Osmosis Process (Osmotic Sink Reverse Osmosis Process를 이용한 에탄올의 농축특성에 관한 연구)

  • 이광현
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.04a
    • /
    • pp.1-4
    • /
    • 1992
  • 기존의 일반적인 에탄올 제조법으로는 1) ethylene의 가수분해, 2)전분이나 당분의 발효, 3)acetylene으로부터 얻은 acetaldehyde의 환원반응이 있다. 기존의 화석연로에 의존하지 않고 에탄올을 생성하는 방법은 발효에 의한 방법이다. 발효에 의해 생성되는 에탄올의 농도는 batch식 발효에서 13-14%, 고정화 발효방법에서 5-10%정도이다. 이를 고순도의 에탄올로 농축하기 위한 방법으로는 증류법, 투과증발법, 역삼투법등이 있으며 증류를 이용하여 농축하는 경우에는 상당히 큰 열에너지를 필요로 한다.

  • PDF

A Study on the Ethanol Concentration by Osmotic Sink Reverse Osmosis Process (Osmotic Sink Reverse Osmosis Process를 이용한 에탄올의 농축특성에 관한 연구)

  • 이광현;민병렬
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.33-48
    • /
    • 1992
  • OSRO process was developed and it was confirmed more effective in ethanol concentrating process comparing to reverse osmosis process. It may be industrialized if more effective membrane for OSRO and reverse osmosis, which indicate the value greater than zero, it was shown that OSRO process was more effective than reverse osmosis for the ethanol concentration process. The decrease of feed concentration and flow rate and the increase of applied pressure made more effective operating conditions in OSRO process to concentrate ethanol. From the numerical esults for the multi-plates, theoretical DC values of reverse osmosis and OSRO process was increased as the umber of stages increased. DC values were increased with the increase of applied pressure in same number of stages. The theoretical values of DC by numerical calculation were corresponded to the experimental values within 15% tolerance. DC value was increased proportional to applied pressure and osmotic sink solution flow rate but it was decreased proportional to feed concentration and flow rate. The numerical calculation over the wide ranges inclading experimental condition was proposed in this study.

  • PDF

Pilot-Scale Simulation of Desalination Process Using Water Integrated Forward Osmosis System (물통합형 정삼투 시스템을 이용한 파일럿 스케일 담수 공정 모사)

  • Kim, Bongchul;Hong, Seungkwan;Choi, Juneseok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.403-408
    • /
    • 2017
  • In these days, wastewater reclamation and seawater desalination play essential role in addressing the challenge of worldwide water scarcity. Particularly, reverse osmosis (RO) for seawater desalination process is commonly used due to less energy consumption than conventional thermodynamic systems. However, membrane fouling and electrical energy consumption during operation of RO system for seawater desalination haver continued to be a obstruction to its application. In this study, therefore, wastewater secondary effluent is used for osmotic dilution of seawater. Firstly, fouling behaviour of RO by simulating wastewater effluent in osmotic dilution process was measured and we calculated energy consumption of overall desalination process by theoretical equations and commercial program. Our results reveal that RO membrane fouling can be efficiently controlled by pre-treatment systems such as nano filtration (NF) or forward osmosis (FO) process. Especially FO system for osmotic dilution process is a non-pressurized membrane system and, therefore, the operating energy consumption of overall desalination system was the lowest. Moreover, fouling layer on FO membrane is comparatively weak and reversible enough to be disrupted by physical cleaning. Thus, RO system with low salinity feed water through FO process is possible as a less energy consuming desalination system with efficient membrane fouling control.

THE REVERSE OSMOSIS PROCESS

  • Erickson, Steve
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.04a
    • /
    • pp.9-9
    • /
    • 1991
  • This paper will begin by describing osmosis and how reverse osmosis works. It will show how osmotic pressure affects reverse osmosis operations. It uill explain salt rejection, membrane flux, and recovery rates and the affect that salt built up has on membrane performance. It wil 1 explain the limitations of RO performance and why pretreatment is important. It will describe the two basic types of membrane, asymmetric and thin-film composite and explain the difference between these types plus compare cellulose acetate types to aromatic polyamide type membranes. It will discuss operating efficiences as it compares to feedwater pressure, concentration, temperature and pH. Finally, it will discuss the differences between tubular, plate and frame, hollow fiber and spiral wound element design. It will be a paper that talks about the basics of RO systems and should give a person who is unfamiliar with RO a basic introduction to this type of separation technology.

  • PDF

Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module (평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향)

  • Kim, Sun-Il;Lee, Bong-Woo;Yun, Young-Jae
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF

MXene Based Composite Membrane for Water Purification and Power Generation: A Review (정수 및 발전을 위한 맥신(MXene) 복합막에 관한 고찰)

  • Seohyun Kim;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.181-190
    • /
    • 2023
  • Wastewater purification is one of the most important techniques for controlling environmental pollution and fulfilling the demand for freshwater supply. Various technologies, such as different types of distillations and reverse osmosis processes, need higher energy input. Capacitive deionization (CDI) is an alternative method in which power consumption is deficient and works on the supercapacitor principle. Research is going on to improve the electrode materials to improve the efficiency of the process. A reverse electrodialysis (RED) is the most commonly used desalination technology and osmotic power generator. Among many studies conducted to enhance the efficiency of RED, MXene, as an ion exchange membrane (IEM) and 2D nanofluidic channels in IEM, is rising as a promising way to improve the physical and electrochemical properties of RED. It is used alone and other polymeric materials are mixed with MXene to enhance the performance of the membrane further. The maximum desalination performances of MXene with preconditioning, Ti3C2Tx, Nafion, and hetero-structures were respectively measured, proving the potential of MXene for a promising material in the desalination industry. In terms of osmotic power generating via RED, adopting MXene as asymmetric nanofluidic ion channels in IEM significantly improved the maximum osmotic output power density, most of them surpassing the commercialization benchmark, 5 Wm-2. By connecting the number of unit cells, the output voltage reaches the point where it can directly power the electronic devices without any intermediate aid. The studies around MXene have significantly increased in recent years, yet there is more to be revealed about the application of MXene in the membrane and osmotic power-generating industry. This review discusses the electrodialysis process based on MXene composite membrane.

Forward Osmotic Pressure-Free (△𝜋≤0) Reverse Osmosis and Osmotic Pressure Approximation of Concentrated NaCl Solutions (정삼투-무삼투압차(△𝜋≤0) 법 역삼투 해수 담수화 및 고농도 NaCl 용액의 삼투압 근사식)

  • Chang, Ho Nam;Choi, Kyung-Rok;Jung, Kwonsu;Park, Gwon Woo;Kim, Yeu-Chun;Suh, Charles;Kim, Nakjong;Kim, Do Hyun;Kim, Beom Su;Kim, Han Min;Chang, Yoon-Seok;Kim, Nam Uk;Kim, In Ho;Kim, Kunwoo;Lee, Habit;Qiang, Fei
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.235-252
    • /
    • 2022
  • Forward osmotic pressure-free reverse osmosis (Δ𝜋=0 RO) was invented in 2013. The first patent (US 9,950,297 B2) was registered on April 18, 2018. The "Osmotic Pressure of Concentrated Solutions" in JACS (1908) by G.N. Lewis of MIT was used for the estimation. The Chang's RO system differs from conventional RO (C-RO) in that two-chamber system of osmotic pressure equalizer and a low-pressure RO system while C-RO is based on a single chamber. Chang claimed that all aqueous solutions, including salt water, regardless of its osmotic pressure can be separated into water and salt. The second patent (US 10.953.367B2, March 23, 2021) showed that a low-pressure reverse osmosis is possible for 3.0% input at Δ𝜋 of 10 to 12 bar. Singularity ZERO reverse osmosis from his third patent (Korea patent 10-22322755, US-PCT/KR202003595) for a 3.0% NaCl input, 50% more water recovery, use of 1/3 RO membrane area, and 1/5th of theoretical energy. These numbers come from Chang's laboratory experiments and theoretical analysis. Relative residence time (RRT) of feed and OE chambers makes Δ𝜋 to zero or negative by recycling enriched feed flow. The construction cost by S-ZERO was estimated to be around 50~60% of the current RO system.

Understanding on TDS Creep Phenomena of Reverse Osmosis Membranes in Water Purifiers (역삼투막 정수기에서 발생하는 총용존고형물 크리프 현상의 이해)

  • Kang, Sanghyeon;Yun, Sunghan
    • Membrane Journal
    • /
    • v.32 no.2
    • /
    • pp.126-132
    • /
    • 2022
  • Water purifiers have a quite different characteristic in comparison with general membrane water treatment processes in which the running and resting are repeated dozens of times a day. In the case of water purifiers using reverse osmosis membranes, this characteristic makes a phenomenon that the total dissolved solids (TDS) of permeate in water purifiers at the beginning of running shows a higher value than a normal value (TDS reduction is lower than a normal value). It is called "TDS creep". The effects of resting times and feed concentrations on the TDS creep were investigated. The feed flushing, the volume increase in permeate side and the flushing with purified water were applied to reduce TDS creep and the effectiveness were observed. Among these trials, the minimization of concentration between feed and permeate side of reverse osmosis membrane like the flushing with purified water can be an ultimate solution to reduce the TDS creep.

Analysis of the Salt Separation and Concentration Using Counter-current Reverse Osmosis Spiral Wound Module (향류식 역삼투 나권형 모듈을 이용한 염분리농축 특성 해석)

  • 조한욱;민병렬;최광호
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.142-151
    • /
    • 1994
  • Counter-current type reverse osmosis spiral wound module was manufactured for the separation and concentration of salf solution. The ratio of permeate volumetric flow rate vs. brine volumetric flow rate was effective parameter between rejection and degree of cocentration. The reflection coefficient was correspondent to the relation between rejection and degree of cocentration by Spiegler-Kedem model. Counter-current reverse osmosis process had more osmotic pressure drop effect and more degree of concentration than general reverse osmosis process. As a result of computer calculation, the extension of module length than module diameter was more effective for the increase of degree of concentration.

  • PDF

Potassium Pentane-1,3,3,5-tetracarboxylate Draw Solute Synthesis and Application of Forward Osmosis Process (Potassium Pentane-1,3,3,5-tetracarboxylate 유도용질 합성 및 이를 이용한 정삼투 공정 응용)

  • Lee, Hye-Jin;Choi, Jin-Il;Kwon, Sei;Kim, In-Chul
    • Membrane Journal
    • /
    • v.29 no.2
    • /
    • pp.111-121
    • /
    • 2019
  • An organic citrate series draw solute was synthesized using diethyl malonate for forward osmosis. The structure of the final compound potassium pentane-1,3,3,5-tetracarboxylate was confirmed by $^1H-NMR$ and $^{13}C-NMR$ analysis. Osmotic pressure, solubility, water permeability and reverse salt flux were measured for the properties of the draw solute. Forward osmosis results showed that the draw solute exhibited higher water flux than other draw solutes of trisodium citrate and tripotassium citrate. Reverse salt flux of all the organic daw solutes was much lower than that of NaCl. The osmotic pressure of the synthesized draw solute was 25% lower than that of NaCl. The solubility of the draw solute was 317 g/ 100 g water, which is 8.8 times higher than that of NaCl. A commercialized nanofiltration membrane was used for the recovery of the draw solute. The draw solute could be effectively recovered at low pressure.