• Title/Summary/Keyword: Reusing Sewage Treatment Water

Search Result 9, Processing Time 0.024 seconds

A study on the device introduction of wastewater reclamation system a treated sewage (하수처리수를 활용한 중수도의 도입방안 연구)

  • Park, Rho-Sam;Park, Sang-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.23-33
    • /
    • 1999
  • After studying several methods of the application a device of a treated sewage in anticipation of the future shortage of the duty of water, we could have some conclusion as the following : Advanced treatment systems arc essential prerequisites in reusing a treated sewage. And in a short term, the application of reusing a treated sewage should go first to new building areas near the sewage but for the long run, it should cover the whole area of Taegu, it is desirable that the pipe line networks which include dual water systems as well as water supply should be spread throughout the whole city. The city authorities have to make every effort to step up publicity activities on this plan to all the citizens and building owners to steadily carry out this project and encourage private constructors to participate with the help of SOC. And for the long run, it is desirable that the application of reusing a treated sewage should be obligatory.

  • PDF

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

An Ecological Restoration of Treatment Wetland and Urban Upper Stream for Reusing Sewage Treatment Water - In the case of Sustainable Structured Wetland Biotop System at Upper Part of Jaemin Stream in Gongju-si, Korea - (하수처리수의 재이용을 위한 처리습지 및 도시 상류하천 생태환경복원 - 공주시 제민천 생태적수질정화비오톱을 중심으로 -)

  • Byeon, Chan-Woo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.5
    • /
    • pp.65-77
    • /
    • 2014
  • The ecosystem of Jaemin stream, flowing into the center of Gongju-si, had been damaged by low water quality and lack of water quantity of the steam. However, after applying the SSB (Sustainable Structured wetland Biotop) system to the flood plain and the upstream of Jaemin stream, the efficiency of ecological water purification and ecological restoration are as follows. Through the constant maintenance and monitoring from year 2009 to year 2013 after restorative design and construction the average influent concentration of BOD5 was 4.2 mg/L, and the average effluent concentration was 1.8 mg/L, reaching ecological water purification rate of 57%. As for the T-N, the average influent concentration was 9.983 mg/L, and the average effluent concentration was 6.303 mg/L, showing the rate of 37%. For the T-P, the average influent concentration was 0.198 mg/L, and the average effluent concentration was 0.098 mg/L, being the rate of 51%. The vegetation of Jaemin stream monitored for 2 years after the restoration was composed of 51 species in 28 families which show high ratio of planted native species. As for the animals in the site, 5 species in 3 families of reptiles and amphibians, 34 species of 23 families of birds, and 3 species in 2 families of mammals were monitored, indicating that the bio-diversity of the site has improved, as well.

Reuse Methods of Treated Sewage for securing Water Resource in Busan (부산시 수자원 확보를 위한 하수처리수 재이용 방안)

  • Kim, Jung-Bae;Moon, Seung-Gun;Park, Yool
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1232-1237
    • /
    • 2009
  • Recently, we often encounter water shortage problem due to drought during dry season. Although we have built dams and expanded our tap water system greatly to meet the increasing demand of water, this approach has its inherent limitation including environmental destruction in the course of the dam construction. Therefore, this paper is aimed to analyze the water recycling models developed in other countries and modify them to fit into our system. Also the water recycling system in Busan municipal area was analyzed to propose an alternative method for reusing the recycled water from wastewater treatment area.

  • PDF

Research on composting of sewage sludge using dryer facility with indirect heating system (간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구)

  • Baik, Seon-Jai;Han, In-Sup;Choi, Ick-Hoon;Kang, Sung-Hyo;Hong, Seong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

Application of Ultra Rapid Coagulation for Securing Water Resource II: Study of CSO Treatment and Sludge Reuse (수자원 확보를 위한 URC공법의 적용 II: CSO의 처리와 슬러지 재활용에 관한 연구)

  • Park, Se Jin;Yoon, Tai Il;Cho, Kyung Chul;Kim, Chang Gyun
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.39-49
    • /
    • 2000
  • Ultra Rapid Coagulation (URC) can dramatically remove pollutants loaded in wastewater by adding weighted coagulation additives (WCA) and recycling sludge into the coagulation basin to increase settling velocity and surface adsorption ability of floc. Also settling chamber together with lamella plates offers the high rate settling velocity, which can economically treat a considerable amount of pollutants like as combined sewage overflow (CSO) during the heavy rainfall and reduce the pollutants load into the receiving water for securing water source. It was estimated optimal configuration of settling chamber by using fluent model and the possibilities of reusing the sludge generated in this system.

  • PDF

A Study on the Stability and Sludge Energy Efficiency Evaluation of Torrefied Wood Flour Natural Material Based Coagulant (반탄화목분 천연재료 혼합응집제의 안정성 및 슬러지 에너지화 가능성 평가에 관한 연구)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.271-282
    • /
    • 2020
  • Sewage treatment plants are social infrastructure of cities. The sewage distribution rate in Korea is reaching 94% based on the sewage statistics based in the year of 2017. In Korean sewage treatment plants, use of PAC (Poly Aluminum Chloride) accounts for 58%. It contains a large amount of impurities (heavy metal) according to the quality standards, however, there have been insufficient efforts to reinforce the standards or technically improve the quality, which resulted in secondary pollution problems from injecting excessive coagulant. Also, the increase in the use of chemicals is leading to the increases in the annual amount of sewage sludge generated in 2017 and the need to reuse sludge. As such, this study aims to verify the possibility of reusing sludge by evaluating the stability of heavy metals based on the injection of coagulant mixture during water treatment which uses the torrefield wood powder and natural materials, and evaluating the sedimentation and heating value of sewage sludge. As a result of analyzing heavy metals (Cr, Fe, Zn, Cu, Cd, As, Pb, and Ni) from the coagulant mixture and PAC (10%), Cr, Cd, Pb, Ni, and Hg were not detected. As for Zn, while its concentration notified in the quality standards for drinking water is 3 mg/L, only a small amount of 0.007 mg/L was detected in the coagulant mixture. Maximum amounts of over double amounts of Fe, Cu, and As were found with PAC (10%) compared to the coagulant mixture. Also, an analysis of sludge sedimentation found that the coagulant mixture showed a better performance of up to double the speed of the conventional coagulant, PAC (10%). The dry-basis lower heating value of sewage sludge produced by injecting the coagulant mixture was 3,378 kcal/kg, while that of sewage sludge generated due to PAC (10%) was 3,171 kcal/kg; although both coagulants met the requirements to be used as auxiliary fuel at thermal power plants, the coagulant mixture developed in this study could secure heating values 200 kal/kg higher than the counterpart. Therefore, utilization of the coagulant mixture for water treatment rather than PAC (10%) is expected to be more environmentally stable and effective, as it helps generating sludge with better stability against heavy metals, having a faster sludge sedimentation, and higher heating value.

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

A Study on Efficiency of Water Purification of Korean Village Bangjuk[dike] as a Means of Ecological Watershed Management (생태적 유역관리 도구로써 마을방죽의 수질정화 효율성 고찰)

  • An, Byung-Chul
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.90-100
    • /
    • 2012
  • This study centering on 10 village - Bangjuks analyzed multifunctionality value of village Bangjuks which have been main water treatment system in Korean traditional villages. On the basis of understanding the structure and character of components such as the well, common spring, village waterway and others which making water-flow and consisting of aquatic system in Korean traditional village Bangjuk, the conclusion as the instrumental device of social and ecological role and ecological watershed management, securing the ecosystem soundness of the damaged or deteriated aquatic ecosystem due to the industrialization and urbanization is as below; 1. The traditional village Bangjuk was environmentally friendly hydraulic system which gathers waterways of village into a point including sewage water, retains and flows out to village through agricultural waterway. Through this Bangjuk, they have managed sewage and rainfall runoff flowed out village efficiently. It is not only a detention system of water but a kind of eco-friendly system that flow out water into the rivers after reusing and filtering it. 2. Around five traditional villages and five villages after modernization, this study classified the types of village Bangjuk as three types considering geographic location, size, etc; marsh type of low swamp, high water -low rice field type of natural flow stucture, low water - high rice field type requiring artificial irrigation facility. All the five traditional villages were turned out to be marsh type of low swamp. Geoji, Sanjeri, Ma-am, Yangchon of the agricultural villages were high water-low rice filed type, and Sangchoenri village was classified low water-high rice field type. 3. This study checked up the function of water purification of village Bangjuk. In Wonteo and Geji villages affected by discharge of village sewer and domestic sewage, the efficiency of ammonia nitrogen($NH_3-N$) and total phosphorus(T-P) was 56~95%, which was high. In Sangcheonri and Sanjeri villages strongly affected by stall and farmland, the efficiency of suspended solids(SS) was 70~85%, and that of total nitrogen(T-N) and total phosphorus(T-P) was 5.3~65%. 4. A water purification system can be found out in the system of village Bangjuk that filter out village sewage and rainfall runoff flowed through the settle and filter of pollution source and denitrification of plants. Through this system of village Bangjuk, it must be used as the basic facilities for the ecological watershed management. The sewage management system of village Bangjuk as a eco-filter must be used and studied as an eco-friendly facility for the ecological watershed management around the subwatershed and catchment.