• Title/Summary/Keyword: Reticle

Search Result 31, Processing Time 0.023 seconds

A digital filter design applied to the manual tracking system to predict future position (차량의 미래위치 추정을 위한 수동추적 시스템의 디지털 필터 설계)

  • 박용운;강윤식;김상원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1332-1335
    • /
    • 1996
  • It is very important to predict the future position for the heavy vehicle with evasive maneuvering. In this paper, we considered for the manual image tracking system. The vehicle images are received from gyro stabilized mirror system, pass through the optical lens, processed, and displayed on the TV monitor. The operator try to lay the reticle to the center of vehicle image. When the vehicle is moving, the mirror platform (actually the line of sight) should follow the vehicle and the angular rate information is picked up from the mirror stabilized system. This rate signal should be used to predict the future vehicle position. The problem is that the visual system of the human operator is in the closed loop system. The rate signals are disturbed by the operator. In addition, there are some non linearities concerned with the control handle bar and the servo control system. The proposed Kalman filter, combined with some modifications for operator disturbance rejection, improved the predication of the future vehicle position when compared with the conventional passive filter used.

  • PDF

Automatic target-recognition technique using a neural network (신경회로망을 이용한 표적의 자동인식 기법)

  • Tahk, Min-Je;Rew, hyuk;Yoo, Inn-Eark;Lee, Won-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.430-435
    • /
    • 1992
  • This paper presents a real-time algorithm for an infrared seeker to find the real target automatically against various background noises without changing the reticle configuration. The modeling technique of infrared sources and analysis results of the various source types based on the FFT algorithm are included. Futhermore, a neural network is used to recognize the source type using the results of FFT analysis. The evaluation of target recognition for cases which can happen in real situation is also treated.

  • PDF

Droplet size measurement using image processing method (이미지프로세싱 기법을 이용한 액적크기 측정)

  • Lim Byoungjik;Jung Kihoon;Khil Taeock;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • Droplet size is one of the most important parameter which controls the performance of the combustion system using liquid fuel or oxidizer. Droplet formation and its size are mainly affected by the injection velocity and ambient gas density. Recently, droplet size measurement was conducted by PDPA or Malvern particle analyzer using laser light. But at this paper image processing method was developed to measure droplet size. And its validation was investigated with reticle.

  • PDF

Microlens Fabrication by Using Excimer Laser (엑사이머 레이저를 이용한 마이크로렌즈 제작)

  • 김철세;김재도;윤경구
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.33-39
    • /
    • 2003
  • A new microlens fabrication technique, the excimer laser lithography is developed. This bases on the pulsed laser irradiation and the transfer of a chromium-on-quartz reticle on to the polymer surface with a proper projection optics system. An excimer laser lithography system with 1/4 and 1/20 demagnification ratios was constructed first, and the photoablation characteristics of the PMMA and Polyimide were experimentally examined using this system. For two different shapes of microlenses, a spherical lens and a cylindrical lens, fabrication techniques were investigated. One for the spherical lens is a combination of the mask pattern projection and fraction effect. The other for the cylindrical lens is a combination of the mask pattern projection and the relative movement of a specimen. The result shows that various shapes of micro optical components can be easily fabricated by the excimer laser lithography.

Research on the Implementation of Infrared Threat Surrogate for DIRCM Performance Analysis (지향성 적외선 방해장치 성능분석을 위한 위협체모사기 구축에 관한 연구)

  • Chun, Seung-Woo;Kim, Joy;Cho, Soo-Hyung;Kim, Jae-Hyup;Yu, Hyun-Geun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.3
    • /
    • pp.97-106
    • /
    • 2015
  • In this paper, the development of infrared threat surrogate system is described and it can be used to verify the performance of DIRCM system. In this research, threat surrogates are manufactured using same F# and reflective optics used in 1st- and 2nd-Gen. real seeker so that the threat surrogate system can be used to develop code-based jamming techniques. Also the threat surrogate system can analyze the saturation jamming effect for image seeker using FPA detector. The result shows that 1st- and 2nd-generation threat surrogates have relatively precise tracking performance and jamming effect.

Development of Dot Sight with Prism Beam Splitter (빔분리프리즘 도트사이트 장치의 개발)

  • Lee, Dong-Hee;Jung, Bo-Seon;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.519-524
    • /
    • 2013
  • Purpose: This study relates to the development of dot-sight device, whose length is reduced, with a prism beam splitter. Methods: We developed a new dot-sight device whose length was reduced by eliminating the optical axis tilt of the doublet reflector to reduce the occurrence of the parallax and by redesigning the doublet reflector to use a prism beam splitter. Results: We could develop the new type dot-sight device having a prism beam splitter and the dot reticle generator and the doublet reflector, of which optical axises showed a T-letter type with the optical axis of the observer's eye. Conclusions: In this study, we designed and developed a new type dot sight employing a prism beam splitter that could be able to further enhance the accuracy of the fire in comparison with the traditional dot sight, thereby reducing the overall optical length of system. The new designed dot sight was able to be reduced 2.2 times on the overall optical length, and could be improved more than three times on the accuracy of shooting in the horizontal direction, than the traditional dot sight.

An Experimental Study on the Spray Characteristics by Twin-Fluid Atomizer for Wide Band Spray (광폭면 분무를 위한 2유체 노즐의 분무 특성에 관한 연구)

  • Lee, Joong-Soon
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.212-219
    • /
    • 2008
  • To develop the twin-fluid atomizer having the excellent performance of painting, the spray characteristics of how a wide area can be painted efficiently by one time spraying were studied in this paper. Spray phenomena are affected by the many factors determining the spray field such as the spraying pressure of gas, the spraying pressure and viscosity of liquid paints, the opening duration of needle valve, the design dimension of nozzle, and so on. As the results of experiments, these factors affecting on spray characteristics were suggested as followings; 1) The optimum spraying pressure of gas was $0.015{\sim}0.02\;kPa$, and the appropriate spraying pressure of liquid paint was 0.01kPa, In these situations, the setting up pressures must be compensated as much as the losing amount of pressure because a decompression occurred when operating valves. 2) The duration of opening the needle valve must be sustained for $1{\sim}2$ seconds to inject gas after spraying the liquid paint. This operating of the needle valve was necessary to avoid the affect on the changing of liquid column length, and to prevent the droplet deposit at the initial time of spraying. 3) The spray tip penetration was gained form the experimental equation, and the effective spraying angle was $85^{\circ}{\pm}5^{\circ}$ just at he appropriate spraying pressure of gas. The distribution of the area sprayed had the variation in $350{\pm}50\;mm$ because of the spraying pressure of gas, the its distance from the spray tip, and the lift of the needle valve.

  • PDF

Development on a Roofed Pechan Prism Type Scope with Long Eye Relief (긴 안점거리를 갖는 지붕형 페찬 프리즘 타입 스코프 개발)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.247-255
    • /
    • 2010
  • Purpose: Developing a roofed Pechan prism type scope with long eye relief. Methods: To reduce the overall length and to lengthen the eye relief of scope, the objective part was designed by adopting the roofed Pechan prism and also the eyepiece part was designed by adopting the field lens with minus refractive power in front of reticle, respectively. Finally, by integrating above two parts, the roofed Pechan prism type scope with 90 mm eye relief was developed. Results: The characteristics of the developed and fabricated scope with 90 mm eye relief by integrating the objective part with the roofed Pechan prism and the eyepiece part with minus refractive power had the magnification of $+3.0{\times}$, the length from the 1st lens to the last lens of about 121 mm, the barrel diameter of 28 mm, and the effective objective-diameter of 17 mm. Also it was found that the line width of resolution was about 900 cycles/rad at the 50% MTF value criterion. Conclusions: We could design and manufacture the roofed Pechan prism type scope with 90 mm eye relief, the characteristics of which had the magnification of $3.0{\times}$, the MTF above 50% at 900 cycles/rad, and the length from the 1st lens to the last lens of about 121 mm.

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF