• Title/Summary/Keyword: Retention of complete dentures

Search Result 50, Processing Time 0.021 seconds

각종 의치상재료가 상악총의치의 유지에 미치는 영향에 관한 실험적 연구

  • Lee, Eun-Ho
    • The Journal of the Korean dental association
    • /
    • v.12 no.9
    • /
    • pp.667-677
    • /
    • 1974
  • A testing machine was devised and constructed for the purpose of measuring the retentive forces of maxillary complete denture bases in subjects. Forth complete denture bases were made for ten subjects with three different denture base materials, following the usual denture construction technique. Retentive forces of the forty dentures were determined at seven locations. The tests on each base were repeated three times at intervals of 5 minutes. Differences in retention values were evaluated statistically. 1) Differences in retention values were found by the differences of the denture base materials, but acrylic resin was similar to chromium cobalt alloy. 2) The chromium cobalt alloy and acrylic resin bases from master models revealed the best retention values, the gold alloy base from master model was the poor second and the acrylic resin base from snap model was the third. 3) The retention values for hook-1 revealed higher than that for hook-2 and the retention values for hook-3 revealed the lowest value.

  • PDF

Complication rates and patient satisfaction with removable dentures

  • Bilhan, Hakan;Erdogan, Ozge;Ergin, Selen;Celik, Melahat;Ates, Gokcen;Geckili, Onur
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.109-115
    • /
    • 2012
  • PURPOSE. The purpose of this clinical study was to evaluate the frequency and type of prosthetic complications in relation to type and properties of removable dentures and to investigate the influence of these complications and several data about the existing dentures on patient satisfaction. MATERIALS AND METHODS. Ninety nine patients (44 males and 55 females) wearing removable dentures have been included in the study. The complications of the patients were recorded; patient satisfaction was determined with a Visual Analog Scale (VAS) and the relationship of complications and patient satisfaction with several data about the dentures such as denture age, type of denture, centric relation and vertical dimension was investigated. Kruskal Wallis, Mann Whitney U and Chi square tests were used for statistical analyses. The results were evaluated statistically at a significance level of $P$ <.05. RESULTS. Need for addition of artificial teeth for dentures with correct centric relations was found to be significantly lower than dentures with wrong centric relations ($P$ <.01). Loss of retention, ulcerations and high vertical dimension affected the VAS chewing ability scores negatively and ulcerations affected the VAS phonation scores negatively ($P$ <.05). CONCLUSION. Considering the results of this study, it can be concluded that loss of retention, ulcerations and high vertical dimension caused patient dissatisfaction. Additionally, dentures with wrong centric relations caused need for addition of artificial teeth.

3-step digital complete denture restoration using facialscan: a case report (안면 스캔을 이용한 3회 내원 디지털 총의치 수복: 증례보고)

  • Yeongseok Kwon;Seoung-Jin Hong;Janghyun Paek;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon;Kwantae Noh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.356-366
    • /
    • 2023
  • Support, retention, and stability of dentures are key factors in the use of complete dentures in edentulous patients. With the development of digital dentistry, attempts are being made to replace traditional treatment methods. Also, struggle to reduce the number of patient visits and to manufacture high-quality digitally fabricated dentures are ongoing. In this case, a digital denture was restored using a tray capable of obtaining centric relation through gothic arch tracing and a facial scan. By replacing the traditional complete denture restoration method, the number of patient visits was reduced and esthetic results with satisfactory denture support, retention, and stability were obtained.

Complete denture treatment using lingualized occlusion scheme at the edentulous patient with severely absorbed flat residual ridges: a case report (심한 치조골 흡수로 인해 편평한 치조제를 보이는 완전 무치악 환자에서 설측 교두 교합을 이용한 의치 수복 증례)

  • Choi, Bum-Shik;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.207-215
    • /
    • 2017
  • Many factors should be considered for successful denture treatment at edentulous patients: support, retention, stability, occlusion, esthetics, etc. The patient who has severely absorbed residual ridges, however, treatments are challenging to satisfy those factors. The dentures that use anatomic artificial teeth show good mastication efficiency and esthetics but, can easily lose stability at absorbed ridges. On the contrary, the dentures that use non-anatomic artificial teeth perform better stability but, lower masticatory efficiency and esthetics at absorbed ridges. The lingualized occlusion, using both anatomic and non-anatomic teeth, introduced for compromise those of the pros and cons. At lingualized occlusion, buccal cusps of the teeth do not contact on centric relation. Therefore, direction of the occlusal force towards lingually, then stability of dentures increases. This case report shows the results of the treatment flat residual ridges using complete dentures with ligualized occlusion to increase dentures stability and satisfactory of the patient.

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report (CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례)

  • Lee, Han-na;Shim, Ji-Suk;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.374-381
    • /
    • 2022
  • This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.

Complete denture made with closed-mouth impression technique on severely atrophied edentulous jaw (하악 치조골이 심하게 위축된 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Lee, Suk-Hwan;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.195-202
    • /
    • 2019
  • At the department of prosthodontics, the elderly patients with severely atrophied alveolar ridge who have been wearing complete dentures for a long period frequently visit the clinic. In general, the open-mouth impression technique for manufacturing a mandibular complete denture to secure primary support on buccal shelf area has been prevalent. In addition, for securing retention and stability of mandibular denture, we should consider diagnosis, oral function, denture border, occlusal plane, teeth arrangement, and patient training, etc.. But in edentulous patients with severe alveolar bone atrophy, it may hardly secure retention and stability of mandibular complete denture. To promote these, some of clinicians are making an attempt manufacturing the mandibular complete dentures using closed-mouth impression technique based on several reports that compare various impression techniques including open-mouth and closed-mouth impression technique. This case report suggests closed-mouth impression technique may promote retention and stability of mandibular complete denture and compares between the two impression techniques clinically.

Evaluation of suitability and stability in a skeletal Class III complete denture patient with flabby tissue: A case report (Flabby tissue를 동반하는 골격성 Class III 환자의 양악 총의치 수복 및 적합성/안정성 평가 증례)

  • Lee, Junsuk;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • To obtain denture retention, support, and stability in Class III edentulous cases with flat alveolar ridges and extensive flabby tissue is very difficult. The patient was a 72-year-old male who wore ill-fitting 20 year old dentures made by non-medical institutions. There was flabby tissue on the maxillary anterior ridge. The patient showed Angle Class III skeletal relationship with severe protruded mandible. First, temporary dentures were fabricated to restore the masticatory function, and final dentures were made through non- pressure impression technique and careful the arrangement of the posterior resin teeth. Improvement of the retention and stability of the denture during the occlusal force application is reported.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures

  • Esra Nur Avukat;Canan Akay;Emre Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.214-226
    • /
    • 2023
  • PURPOSE. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.

Complete denture rehabilitation in the edentulous patient with severe mandibular bone resorption and vascular malformation using closed mouth impression and monoplane occlusion: A case report (심한 하악골 흡수와 혈관기형을 보이는 무치악 환자에서 폐구인상법과 단일평면교합법을 이용한 총의치 수복 증례)

  • Kim, Jae-Hyun;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.220-227
    • /
    • 2021
  • A patient failed to use conventional complete dentures due to severe mandibular bone resorption and soft tissue hyperplasia on lips, tongue and oral vestibule from vascular malformation. The treatment of choice would be an implant-retained overdenture, however, he refused owing to high cost. The closed mouth impression technique using BPS principle, CR record registration with gothic arch tracing and monoplane occlusion using non-anatomic teeth were used to fabricate complete dentures for this patient. Patient satisfaction, the retention and the stability of complete dentures were highly improved as a result.