• Title/Summary/Keyword: Retention day

Search Result 462, Processing Time 0.027 seconds

Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale (현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

Effects of Nitrifying Bacterial Communities with Different HRTs and Backwashing Periods in Modified BAF Process (Modified BAF 공정에서 HRT 및 역세주기가 질산화 미생물의 군집에 미치는 영향)

  • Jung, Chul-Soo;Park, Jeung-Jin;Ju, Dong-Jin;Kwon, Soo-Youn;Choi, Won-Seok;Byun, Im-Gyu;Park, Tae-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.920-926
    • /
    • 2007
  • The upflow Biobead$^{(R)}$ process, one of biological aerated filters (BAF), which was used commercially, invented for removal of organic materials and nitrification. This process was modified to enhance the ability of denitrification through the induction of pre-anoxic tank. In this research, we investigated the effects of hydraulic retention time (HRT) and backwashing period in aerobic tank. The characteristics of nitrifying bacteria, which are composed of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB), also investigated using fluorescence in situ hybridization (FISH). Even though the HRT was shortened, the efficiency of nitrification was not decreased when the organic loading rate and ammonium-nitrogen loading rate were $2.10kg/m^3/day$ and $0.25kg/m^3/day$, respectively. And then the distribution ratios of AOB and NOB showed the similar patterns. However, when the backwashing period was lengthened from 12 hours to 24 hours in aerobic 1 tank, the nitrification efficiency was decreased to 63.9% from 89.2%. The results of FISH explained that this decrease of nitrification efficiency was caused by the decrease of distribution ratio of AOB in aerobic 1 tank. The nitrification efficiencies of aerobic 1 and aerobic 2 tank were increased when the backwashing period was lengthened because of relative high distribution ratios of nitrifying bacteria.

Tumoral Accumulation of Long-Circulating, Self-Assembled Nanoparticles and Its Visualization by Gamma Scintigraphy

  • Cho, Yong-Woo;Kim, Yoo-Shin;Kim, In-San;Park, Rang-Woon;Oh, Seung-Jun;Moon, Dae-Hyuk;Kim, Sang-Yoon;Kwon, Ick-Chan
    • Macromolecular Research
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • The enhanced permeability and retention (EPR) effect is used extensively for the passive targeting of many macromolecular drugs for tumors. Indeed, the EPR concept has been a gold standard in polymeric anticancer drug delivery systems. This study investigated the tumoral distribution of self-assembled nanoparticles based on the EPR effect using fluorescein and radio-labeled nanoparticles. Self-assembled nanoparticles were prepared from amphiphilic chitosan derivatives, and their tissue distribution was examined in tumor-bearing mice. The size of the nanoparticles was controlled to be 330 run, which is a size suited for opening between the defective endothelial cells in tumors. The long-circulating polymer nanoparticles were allowed to gradually accumulate in the tumors for 11 days. The amount of nanoparticles accumulated in the tumors was remarkably augmented from 3.4%ID/g tissue at 1 day to 25.9%ID/g tissue at 11 days after i.v. administration. The self-assembled nanoparticles were sustained at a high level throughout the 14 day experimental period, indicating their long systemic retention in the blood circulation. The ${\gamma}$-images provided clear evidence of selective tumor localization of the $^{131}I$-labeled nanoparticles. Confocal microscopy revealed the fluorescein-labeled nanoparticles to be preferentially localized in the perivascular regions, suggesting their extravasation to the tumors through the hyperpermeable angiogenic tumor vasculature. This highly selective tumoral accumulation of nanoparticles was attributed to the leakiness of the blood vessels in the tumors and their long residence time in the blood circulation.

A Basic Study on the Anaerobic Wastewater Treatment using Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조의 혐기성 폐수처리에 관한 기초연구)

  • Kim, Taek-Su;Bae, Min-Su;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.464-469
    • /
    • 2005
  • In the nonwoven fabric filter bioreactor (NFBR), both the construction and the operation costs could be saved because a high concentration of microorganism can be maintained in the reactor as in the membrane bioreactor. However, the NFBR process has been investigated only under aerobic and/or anoxic conditions, In this research, a basic anaerobic treatment experiment was performed at $35^{\circ}C$ by feeding an airtight NFBR with a concentrated synthetic organic wastewater. The organic loading rate (OLR) of the NFBR was increased stepwise from $0.25kg\;COD/m^3-day$ to $0.77kg\;COD/m^3-day$ by gradually decreasing the hydraulic retention time from 20 days to 13 days. The results of the research showed that the best COD removal efficiency achieved at the OLR of $0.67kg\;COD/m^3-day$ with a value of 99.3%. The methane content of the produced gas was highest with a value of 61.2% at the OLR of $0.33g\;COD/m^3-day$. The highest methane production rate was $0.89g\;COD/m^3-day$ at the same OLR. The operation was terminated at the OLR of $0.77kg\;COD/m^3-day$ because of the deterioration in COD removal efficiency, gas production rate, and the methane content of the gas. Further researches are recommended for the NFBR to be employed for anaerobic treatment of organic wastewaters.

The Treatment of Industrial Wastewater by the Fluidized-Bed Biofilm Reactor (미생물막 유동층 반응기를 이용한 산업폐수 처리에 관하여)

  • Suh, Myung-Gyo;Suh, Jung-Ho;Kang, Jun-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.69-77
    • /
    • 1993
  • Substrate removal efficiency of industrial wastewater from dye plant was investigated with fluidized-bed biofilm reactor(FBBR). Wastewater was diluted by 2, 3 and 6 times for experiment. When F/M ratio was increased 0.2 to 0.3, substrate removal efficiency of wastewater was rapidly decreased in all dilution ratio. Substrate removal efficiency was increased with dilution ratio in same F/M ratio, with hydraulic retention time. In case of 6 times diluted wastewater, below 0.2 F/M ratio, removal efficiency of BOD was $90{\sim}97%$. For reactor design, the parameters such as Y, $k_d$ and r was obtained as follows: $Y=0.3365\;k_d=0.03782\;day^{-1}\;r=0.997$ in 2 times diluted $Y=0.3341\;k_d=0.02750\;day^{-1}\;r=0.996$ in 3 times diluted $Y=0.3365\;k_d=0.03434\;day^{-1}\;r=0.998$ in 6 times diluted

  • PDF

The Treatment of Slurry-type Swine Waste using UASB Reactor (UASB 공정에 의한 슬러리형 돈사폐수의 처리)

  • Won, Chul-Hee;Kim, Byoung-Ug;Han, Dong-Joon;Rim, Jay-Myoung
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.583-588
    • /
    • 2004
  • This research examined the treatment efficiency and methane production rate in treating slurry-type swine waste using UASB (upflow anaerobic sludge blanket) reactor. The UASB reactor was operated at an organics volumetric loading rate (VLR) of $2.6-15.7kgCOD/m^3/day$. A stepwise increase of the VLR resulted in a temporary deterioration in the COD removal rate in UASB reactor but recovered quickly. The COD removal rate were 65-70% for VLR up to $5 kgCOD/m^3/day$. When organics VLR was $10kgCOD/m^3/day$, the COD removal rate decreased sharply and there was loss of 17.537g of the seeding biomass due to sludge washout. This result indicated that the UASB system cannot be adapted to more than $10kgCOD/m^3/day$ of VLR. As the organic load increased from 2.6 to $15.7kgCOD/m^3/d$, the biogas production rate varied from 3.2 to 10.8 L/d and the methane conversion rate of the organic matter varied from 0.30 to $0.23m^3CH_4/kg\;COD_{removed}$. The methane content showed the range of 70.1-81.5% during the experimental period. The volatile solids (VS) removal efficiency was similar at the low VLR (< $5 kgCOD/m^3/day$), but it decreased sharply at the high VLR (> $5 kgCOD/m^3/day$). The VS reduction rate was, moreover, large those of COD. The result shows that hydraulic retention time above 2 days is essential in case of treating wastewater containing 1% of solids.

The Rapid Determination of Gemcitabine by Reversed-phase Ultra-Performance Liquid Chromatography (역상 초고속액체크로마토그라피에 의한 gemcitabine의 빠른 농도 분석법)

  • Park, Dae-Jin;Kim, Woo-Mi
    • Journal of Life Science
    • /
    • v.19 no.12
    • /
    • pp.1698-1704
    • /
    • 2009
  • Gemcitabine is an anticancer drug used to treat a variety of solid tumors. The drug is rapidly inactivated by cytidine deaminase in plasma and its hydrophilicity restricts the extent of quantification that is possible using reversed-phase liquid chromatography. In this paper, we report a rapid and precise method to analyze velocity and peak efficiency using ultra-performance liquid chromatography (UPLC) with a reversed-phase column. The retention periods of gemcitabine and 2'-deoxycytidine at 283 nm were 3.2 and 2.1 min, respectively. The assay provided highly linear results in the range of $0.1{\sim}20{\mu}g/ml$ ($r^2$ > 0.999). The coefficients of variation of the intra-day and inter-day assays were less than 10.0%. We observed that the estimated average concentrations of the intra-day and inter-day assays ranged from 97.3 to 113.5% to verify the accuracy. These results suggest that this new reversed-phase UPLC method is a rapid and reliable way of determining gemcitabine levels.

Quantitation of Flurbiprofen in Isopropyl Myristate by High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 미리스틴산이소프로필증 플루르비프로펜의 정량)

  • Kim, Hyun;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.63-68
    • /
    • 1992
  • An HPLC procedure with UV detection has been developed for the quantitation of flurbiprofen released into isopropyl myristate used as the receptor phase in an in vitro membraneless drug diffusion cell. The drug and the internal standard (oxaprozin) were extracted from isopropyl myristate with a mixture of dimethylsulfoxide:methanol:water (2:1:1) and quantitated using a reverse phase $C_{18}$ column. The chromatograms were completely free from interfering peaks, and the relative retention times of flurbiprofen and the internal standard were 4.9 and 6.8 min, respectively. Calibration plots were linear over the concentration range of $1-200\;{\mu}g/ml$ of flurbiprofen with correlation coefficients, all higher than 0.99. The mean intra-day precision and accuracy among three replicate sets of the assay in a day were 4.26 and 4.52%, respectively, whereas the mean inter-day precision and accuracy were 3.35 and 3.64%, respectively. The mean recovery of the drug was 92.5% over the calibration range. The method was simple, reliable and accurate for the quantitation of flurbiprofen in unpurified isopropyl myristate.

  • PDF

THE EFFECT OF CANAL FILLING SEALER TO RESIN CEMENT IN POST CEMENTATION (근관충전용 sealer의 성분이 포스트 세멘트시 레진 세멘트에 미치는 영향)

  • Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of the canal filling sealer to resin cement When posts were cemented in the endodontically treated teeth, 86 incisors were used. The coronal portion of the teeth were removed at the cemento-enamel junction, every tooth was done treatment of canal. And the teeth was divided was into 12 groups. G : I a n : 7 Treatment : Z.P.C (1 day after Z.O.E. sealer) G : I b n : 7 Treatment : All-Bond (3 day after sealer) G : II a n : 8 Treatemt : Z.P.C (3 day after sealer) G : II b n : 7 Treatemt : All-Bond (3 day after sealer) G : III a n : 8 Treatemt : Z.P.C (7 day after sealer) G : III b n : 8 Treatemt : All-Bond (7 day after sealer) G : IV a n : 7 Treatemt : Z.P.C (1 day after Apexit sealer) G : IV b n : 7 Treatemt : All-Bond (1 day after sealer) G : V a n : 7 Treatemt : Z.P.C (3 day after sealer) G : V b n : 7 Treatemt : All-Bond (3 day after sealer) G : VI a n : 7 Treatemt : Z.P.C (7 day after sealer) G : VI a n : 7 Treatemt : All-Bond (7 day after sealer) Ready made stainless steel Para-post(PD-K-3) was cemented with Z.P.C. in subgroup a, and cemented with All-Bond & composite resin cement in subgroup b to depth 7mm. After 5 days at cementation of post, teeth with cemented posts were mounted on a retention jig and the failure loads of the specimens were measured by an Instron Universal Testing Machine. The results were as follows. 1. The results of failure loads were $15.5{\pm}7.1kg$ in group I b, $21.6{\pm}5.4kg$ in group II b and $20.1{\pm}18.1kg$ in group III b, and there was no statistically significant , difference between each group(p>0.05). 2. The results of failure loads were $19.0{\pm}6.7kg$ in group IV b, $17.3{\pm}6.5kg$ in group V b.and $18.9{\pm}7.9kg$ in group VI b and there was no significant difference between each other(p>0.05). 3. In same condition, the failure load of subgroup a was largely higher the subgroup b. But there was no significant difference between each other(p>0.05).

  • PDF

HPLC Method Validation of Naringin Determination in Goheung Yuzu Extract as a Functional Ingredient (건강기능식품 기능성 원료로서 고흥 유자 추출물의 지표성분 Naringin 분석법)

  • Moon, So-Hyun;Ko, Eun-Young;Assefa, Awraris Derbie;Park, Se-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1737-1741
    • /
    • 2014
  • An HPLC method for determination of naringin was developed to standardize it as a marker compound in Goheung yuzu extract as a functional health food. Optimum results were obtained by C-18 column chromatography using solvent mixtures (A: 0.5% acetic acid, B: acetonitrile) as the stationary phase and mobile phase. The method was fully validated and sensitive with a limit of detection (LOD) of 0.0218 mg/L and limit of quantification (LOQ) of 0.0661 mg/L. The method showed high linearity (coefficient of correlation=0.9986) and high accuracy, as recovery rates of naringin at concentrations of 1, 0.5, 0.1, 0.05 mg/mL were in the ranges of 95.74~98.25%, 97.67~101.01%, 97.33~104.64%, and 95.53~106.82%, respectively. Intra-day and inter-day variation, which are measures of method precision, were 1.39~1.95% and 0.17~1.49%, respectively. Therefore, the method could be used without modification for determination of naringin as a marker compound in Goheung yuzu extracts.