• 제목/요약/키워드: Restorative design

검색결과 122건 처리시간 0.024초

도재소부용 18K 금합금의 미량원소의 첨가에 따른 물리적 성질의 변화에 관한 연구 (A Study on Change of Physical Property in Porcelain Fused to 18K Gold Alloy by Small Additional Elements)

  • 이기대
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.31-37
    • /
    • 2008
  • A variety of the porcelain fused to gold(PFG) have been developed to which porcelain can be fused. PFG alloys developed for this purposed have a high melting point and do not discolor when combined with porcelain. The design of the compositions of PFG is very important to esthetic restorative materials applying to porcelain. The purpose of this study is on the change of physical and mechanical characteristics in PFG 18K alloy by the small additional elements. Principal results are as follows. The high Au alloy containing 18Karat gold contents is respectively Au(75%), Pd(10%), Pt(4%), Ag(4%), In(2%), Sn(2%), Cu(2%), Ti(1%). These alloys are composed mainly of gold, platinum, silver and palladium with a few percent of the additional elements. By the addition of small amounts of elements such as In, Sn, Ti, the fine grain castings are produced in gold alloy and the small addition of platinum is very effective in increasing of hardness and strength. These gold alloys are representative of the changes to be expected as a result of heat treatment. These changes in strength and hardness values are sufficient to demonstrate a significant difference in performance between a as-casted and a heat-treated. These alloys have mechanical properties characteristics of Type and Type gold alloys. These alloys are useful to porcelain-metal restorations and dental laboratory. Also the porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory.

  • PDF

How to design in situ studies: an evaluation of experimental protocols

  • Sung, Young-Hye;Kim, Hae-Young;Son, Ho-Hyun;Chang, Juhea
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.164-171
    • /
    • 2014
  • Objectives: Designing in situ models for caries research is a demanding procedure, as both clinical and laboratory parameters need to be incorporated in a single study. This study aimed to construct an informative guideline for planning in situ models relevant to preexisting caries studies. Materials and Methods: An electronic literature search of the PubMed database was performed. A total 191 of full articles written in English were included and data were extracted from materials and methods. Multiple variables were analyzed in relation to the publication types, participant characteristics, specimen and appliance factors, and other conditions. Frequencies and percentages were displayed to summarize the data and the Pearson's chi-square test was used to assess a statistical significance (p < 0.05). Results: There were many parameters commonly included in the majority of in situ models such as inclusion criteria, sample sizes, sample allocation methods, tooth types, intraoral appliance types, sterilization methods, study periods, outcome measures, experimental interventions, etc. Interrelationships existed between the main research topics and some parameters (outcome measures and sample allocation methods) among the evaluated articles. Conclusions: It will be possible to establish standardized in situ protocols according to the research topics. Furthermore, data collaboration from comparable studies would be enhanced by homogeneous study designs.

CAD/CAM으로 제작된 Ceramic Inlay의 변연누출에 관한 비교연구 (A COMPARATIVE STUDY ON MARGINAL LEAKAGE OF CAD/CAM-FABRICATED CERAMIC INLAY)

  • 조병훈;이명종;임미경;이광원;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.702-709
    • /
    • 1997
  • To compare the marginal leakage of CAD/CAM-fabricated ceramic inlay, gold inlay and amalgam, forty extracted caries-free premolars were prepared with Class II MO cavity design. The teeth were divided into four groups of ten samples each. Group 1 was restored with CAD/CAM-fabricated ceramic inlays cemented with Scotchbond Resin Cement / Scotchbond Multi-purpose plus. Group 2 was restored with gold inlays cemented with Scotchbond Resin Cement / Scotchbond Multi-purpose plus. Group 3 was restored with gold inlays cemented with zinc phosphate cement. And, Group 4 was restored with amalgam. All samples were thermocycled, and stored in 1 % methylene blue. Marginal leakage was examined at four margins, that is, occlusal distal, priximal gingival, occlusal facial and occlusal lingual margins from sectioned samples under stereomicroscope(x15). The results were as follows : 1. Group 1 and 2 showed no statistically significant difference among marginal leakage at all four examined margins(p>0.05). 2. Group 3 and 4 showed significant marginal leakage at proximal gingival margin compared with other margins(p<0.05). 3. Significantly increased marginal leakage at priximal gingival, occlusal facial and occlusal lingual margins in group 3 were observed compared with other groups (p<0.05).

  • PDF

V 급 와동 변연부 형태 및 복합레진 종류에 따른 변연 누출에 관한 실험적 연구 (An Experimental Study on the Effects of the Margin Designs and Composite Resins on the Marginal Leakage of Class V Resin Restorations)

  • 신용필;이찬영;이승종;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.107-116
    • /
    • 1986
  • The primary aim of this study was to assess the effects of the margin designs and composite resins on the marginal leakage of Class V resin restorations. 60 Class V cavities with $90^{\circ}$ butt joint, 60 with $45^{\circ}$ bevel joint, and 60 with concave joint were prepared on the labial surfaces of 38 extracted anterior teeth and the buccal and lingual surfaces of 71 premolars, and classified as the butt group, bevel group and concave group, respectively. After completion of the cavity preparation, Heliosit${(R)}$ was filled in 20 butt joint cavities, 20 bevel joint cavities, and 20 concave cavities. And Hi-Pol$^{(R)}$ and Palfique$^{(R)}$ were filled in the same manner, respectively. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$, $37^{\circ}C$, and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours, and buccolingually sectioned with sectioning machine. The sectioned specimens were examined under the light microscope. The results indicated the following: 1. The bevel group showed the least amount of marginal leakage compared with the other two design groups, but the statistical analysis showed no significant difference at the 95% confidence level. 2. Hi-Pol$^{(R)}$ group showed the most severe marginal leakage compared with the other composite resin materials, but there was no significant difference in the groups. 3. The bevel-Heliosit$^{(R)}$ subgroup, which was filled with Heliosit$^{(R)}$ in the beveled cavities, showed the least amount of marginal leakage, but there was no significance in all the subgroups.

  • PDF

Antimicrobial efficacy of QMix on Enterococcus faecalis infected root canals: a systematic review of in vitro studies

  • Lim, Benjamin Syek Hur;Parolia, Abhishek;Chia, Margaret Soo Yee;Jayaraman, Jayakumar;Nagendrababu, Venkateshbabu
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.23.1-23.12
    • /
    • 2020
  • Objectives: This study aimed to summarize the outcome of in vitro studies comparing the antibacterial effectiveness of QMix with other irrigants against Enterococcus faecalis. Materials and Methods: The research question was developed by using population, intervention, comparison, outcome, and study design framework. The literature search was performed using 3 electronic databases: PubMed, Scopus, and EBSCOhost until October 2019. The additional hand search was performed from the reference list of the eligible studies. The risk of bias of the studies was independently appraised using the revised Cochrane Risk of Bias tool (RoB 2.0). Results: Fourteen studies were included in this systematic review. The overall risk of bias for the selected studies was moderate. QMix was found to have a higher antimicrobial activity compared to 2% sodium hypochlorite (NaOCl), 17% ethylenediaminetetraacetic acid (EDTA), 2% chlorhexidine (CHX), mixture of tetracycline isonomer, an acid and a detergent (MTAD), 0.2% Cetrimide, SilverSol/H2O2, HYBENX, and grape seed extract (GSE). QMix had higher antibacterial efficacy compared to NaOCl, only when used for a longer time (10 minutes) and with higher volume (above 3 mL). Conclusions: QMix has higher antibacterial activity than 17% EDTA, 2% CHX, MTAD, 0.2% Cetrimide, SilverSol/H2O2, HYBENX, GSE and NaOCl with lower concentration. To improve the effectiveness, QMix is to use for a longer time and at a higher volume.

Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review

  • Silva, Emmanuel Joao Nogueira Leal;Zanon, Mayara;Hecksher, Fernanda;Belladonna, Felipe Goncalves;de Vasconcelos, Rafaela Andrade;da Silva Fidalgo, Tatiana Kelly
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.25.1-25.12
    • /
    • 2020
  • Objectives: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. Materials and Methods: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. Results: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. Conclusions: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

복합레진 인레이 수복시 와동형태에 따른 치아파절에 관한 유한요소법적 연구 (A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS WITH CAVITY DESIGN ON FRACTURE OF COMPOSITE RESIN INLAY RESTORED TOOTH)

  • 김철순;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.231-254
    • /
    • 1994
  • Fracture of cusp, on posterior teeth, especially those carious or restored, is major cause of tooth loss. Inappropriate treatments, such as unnecessarily wide cavity preparations, increase the potential of further trauma and possible fracture of the remaining tooth structures. Fracture potential may be directly related to the stresses exerted upon the tooth during masticatory function. The purpose of this study is to evaluate the fracture resistance of tooth, restored with composite resin inlay. In this study, MOD inlay cavity prepared on maxillary first premolar and restored with composite resin inlay. Three dimensional finite element models with eight nodes isoparametric solid element, developed by serial grinding-photographing technique. These models have various occlusal isthmus and depth of cavity, 1/2, 1/3 and 1/4 of isthmus width and 0.7, 0.85 and 1.0 of depth of cavity. The magnitude of load was 474 N and 172 N as presented to maximal biting force and normal chewing force. These loads applied onto ridges of buccal and lingual cusp. These models analyzed with three dimensional finite element method. The results of this study were as follows : 1. There is no difference of displacement between width of occlusal isthmus and depth of cavity. 2. The stress concentrated at bucco-mesial comer, bucco-disal comer, pulpal line angle and the interface area between internal slopes of cusp and resin inlay. 3. The vector of stress direct to buccal and lingual side from center of cavity, to tooth surface going on to enamel. The magnitude of vector increase from occlusal surface to cervix. 4. The crack of tooth start interface area, between internal slop of buccal cusp and resin inlay. It progresses through buccopulpal line angle to cervix at buccomesial and buccodistal comer. 5. The influence with depth of cavity to fracture of tooth was more than width of isthmus. 6. It would be favorable to make the isthmus width narrower than a third of the intercuspal distance and depth of cavity is below 1 : 0.7.

  • PDF

The effect of different fluoride application methods on the remineralization of initial carious lesions

  • Byeon, Seon Mi;Lee, Min Ho;Bae, Tae Sung
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.121-129
    • /
    • 2016
  • Objectives: The purpose of this study was to assess the effect of single and combined applications of fluoride on the amount of fluoride release, and the remineralization and physical properties of enamel. Materials and Methods: Each of four fluoride varnish and gel products (Fluor Protector, FP, Ivoclar Vivadent; Tooth Mousse Plus, TM, GC; 60 Second Gel, A, Germiphene; CavityShield, CS, 3M ESPE) and two fluoride solutions (2% sodium fluoride, N; 8% tin(ii) fluoride, S) were applied on bovine teeth using single and combined methods (10 per group), and then the amount of fluoride release was measured for 4 wk. The electron probe microanalysis and the Vickers microhardness measurements were conducted to assess the effect of fluoride application on the surface properties of bovine teeth. Results: The amount of fluoride release was higher in combined applications than in single application (p < 0.05). Microhardness values were higher after combined applications of N with FP, TM, and CS than single application of them, and these values were also higher after combined applications of S than single application of A (p < 0.05). Ca and P values were higher in combined applications of N with TM and CS than single application of them (p < 0.05). They were also increased after combined applications of the S with A than after single application (p < 0.05). Conclusions: Combined applications of fluoride could be used as a basis to design more effective methods of fluoride application to provide enhanced remineralization.

근관와동형태에 따른 근관치료된 하악절치의 파절강도 (THE INFLUENCE OF DIFFERENT ACCESS CAVITY DESIGNS ON THE FRACTURE STRENGTH IN ENDODONTICALLY TREATED MANDIBULAR ANTERIOR TEETH)

  • 이영균;신혜진;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.515-519
    • /
    • 2004
  • Straight access cavity design allows the operator to locate all canals, helps in proper cleaning and shaping, ultimately facilitates the obturation of the canal system. However, change in the fracture strength according to the access cavity designs was not clearly demonstrated yet. The purpose of this study was to determine the influence of different access cavity designs on the fracture strength in endodontically treated mandibular anterior teeth. Recently extracted mandibular anterior teeth that have no caries, cervical abrasion, and fracture were divided into three groups (Group 1 : conventional lingual access cavity, Group 2 : straight access cavity, Group 3 : extended straight access cavity) according to the cavity designs. After conventional endodontic treatment, cavities were filled with resin core material. Compressive loads parallel to the long axis of the teeth were applied at a crosshead speed of 2mm/min until the fracture occurred. The fracture strength analyzed with ANOV A and the Scheffe test at the 95% confidence level. The results of this study were as follows: 1. The mean fracture strength decrease in following sequence Group 1 (4558.90{\;}\pm{\;}77.40{\;}N$), Group 2 ($494.07{\;}\pm{\;}123.98{\;}N) and Group 3 ($267.33{\;}\pm{\;}27.02{\;}N). 2. There was significant difference between Group 3 and other groups (P = 0.00). Considering advantage of direct access to apical third and results of this study, straight access cavity is recommended for access cavity form of the mandibular anterior teeth.

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.