• Title/Summary/Keyword: Response assessment

Search Result 2,042, Processing Time 0.023 seconds

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

A Comparison of Tiotropium 18㎍, Once Daily and Ipratropium 40㎍, 4 Times Daily in a Double-Blind, Double-Dummy, Efficacy and Safety Study in Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Tiotropium 1일 1회, 1회 18㎍ 요법과 Ipratropium 1일 4회, 1회 40㎍ 요법의 치료효과 및 안전성 비교)

  • Kim, Seung Joon;Kim, Myung Sook;Lee, Sang Haak;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Lee, Sang Yeub;In, Kwang Ho;Lee, Chang Youl;Kim, Young Sam;Kim, Hyung Jung;Ahn, Chul Min;Kim, Sung Kyu;Kim, Kyung Rok;Cha, Seung Ick;Jung, Tae Hoon;Kim, Mi Ok;Park, Sung Soo;Choi, Cheon Woong;Yoo, Jee Hong;Kang, Hong Mo;Koh, Won Jung;Ham, Hyoung Suk;Kang, Eun Hae;Kwon, O Jung;Lee, Yang Deok;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun;Shin, Won Hyuk;Kwon, Sung Yeon;Kim, Woo Jin;Yoo, Chul Gyu;Kim, Young Whan;Shim, Young Soo;Han, Sung Koo;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Mi Hye;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul;Choi, Byoung Whui;Oh, Yeon Mok;Lim, Chae Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Jung, Sung Soo;Kim, Ju Ock;Ko, Young Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.498-506
    • /
    • 2005
  • Background : This study compared the bronchodilator efficacy and safety of tiotropium inhalation capsules ($18{\mu}g$ once daily) with a ipratropium metered dose inhaler (2 puffs of $20{\mu}g$ q.i.d.) in patients with chronic obstructive pulmonary disease (COPD). Method : After the initial screening assessment and a two-week run-in period, patients received either tiotropium $18{\mu}g$ once daily or ipratropium $40{\mu}g$ four times daily over a period of 4 weeks in a double blind, double dummy, parallel group study. The outcome measures were the lung function, the daily records of the peak expiratory flow rate (PEFR), the patients' questionnaire, and the use of concomitant salbutamol. The forced expiratory volume in one second ($FEV_1$) and the forced vital capacity (FVC) were measured 5 minutes before inhalation, and 0.5, 1, 2 and 3 hours after inhaling the study drug on days 0, 14 and 28. Result : In 16 centers, 134 patients with a mean (SD) age of 66 (7) years and a predicted $FEV_1$ of 42 (12)% were analyzed. The trough $FEV_1$ response was significantly higher in the tiotropium group than in the ipratropium group after a four-week treatment period. The weekly mean morning PEFR of the tiotropium group was consistently higher than that of the ipratropium group during the 4-week treatment period with differences ranging from 12.52 to 13.88 l/min, which were statistically significant. Tiotropium was well tolerated by the COPD patients during the 4-week treatment period and had a similar safety profile to ipratropium. Conclusion : This study shows that tiotropium administrated once daily has a superior bronchodilator effect with a similar safety profile in treating COPD patients compared with ipratropium, inhaled four times daily.