• Title/Summary/Keyword: Response Threshold

Search Result 425, Processing Time 0.039 seconds

Electro-optical Properties of Twisted Nematic Liquid Crystal Displays Fabricated with TIPS-pentacene Doping

  • Lee, Jin-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.82-85
    • /
    • 2013
  • This paper introduces 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS pentacene) doped liquid crystal (LC) alignment properties on a rubbed polyimide (PI) layer as a function of the doping concentration of TIPS pentacene. Pretilt angles, photomicrographs, and electro-optical properties of TIPS pentacene doped LCs were comparable to those of pure LCs. However, TIPS pentacene in a LC medium supported twisted nematic-liquid crystal displays (TN-LCDs) to improve electro-optical properties. The threshold voltages observed in the TN cells decreased as the TIPS pentacene concentration increased. In addition, suitable response times were observed in TN cells.

Investigation of Electro-optical Characteristics in A-TN-LCD on Poly(vinyl)cinnamate Surfaces (Poly(vinyl)cinnamate막을 이용한 A-TN-LCD의 전기광학 특성)

  • 서대식;박지호;이보호
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.576-580
    • /
    • 1997
  • In this paper, the viewing angle characteristics of amorphous (a) - twisted nematic (TN)-liquid crystal display (LCD) on poly(vinyl)cinnamate (PVC) surface with UV (ultraviolet) light irradiation were investigated. It was found that the threshold voltage increases with increasing the polymerization of PVC surfaces. We observed that the domain size of a-TN-LCD decreases with increasing the photo polymerization by increasing UV light irradiation time on PVC films. Also, we observed that the viewing angle of a-TN-LCD increased with increasing the photo polymerization on PVC surfaces. Finally, we consider that the viewing angle of a-TN-LCD on PVC surfaces is large compared to a-TN-LCD on polyimide (PI) surface.

  • PDF

Evaluation of Optical Characteristics by Panel Current Analysis for Charged Particle Type Display (대전입자형 디스플레이의 패널전류 분석에 의한 광특성 평가)

  • Park, Sun-Woo;Kwon, Ki-Young;Chang, Sung-Keun;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.844-849
    • /
    • 2009
  • The moving behavior of particle with voltage biasing is studied by analyzing the displacement current generated in electrodes and the drift current by moving particles in cell gap. These currents are ascertained by optical reflectivity on the panel. We obtained the saturated current after a peak in threshold voltage which is coincide with reflectivity of 80%. These saturated optical reflectivity and its drift current offer optimum q/m of particles and driving voltage and can be analytically studied on grey scale methods. Especially regional analysis is useful to aging and driving voltage and the understanding of operating mechanism of charged particle type display.

An Optimized File System for SSD (SSD를 위한 최적화 파일시스템)

  • Park, Je-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2010
  • Recently increasing application of flash memory in mobile and ubiquitous related devices is due to its non-volatility, fast response time, shock resistance and low power consumption. Following this trend, SSD(Solid State Disk) using multiple flash chips, instead of hard-drive based storage system, started to widely used for its advantageous features. However, flash memory based storage subsystem should resolve the performance bottleneck for writing in perspective of speed and lifetime according to its disadvantageous physical property. In order to provide tangible performance, solutions are studied in aspect of reclaiming of invalid regions by decreasing the number of erasures and distributing the erasures uniformly over the whole memory space as much as possible. In this paper, we study flash memory recycling algorithms with multiple management units and demonstrate that the proposed algorithm provides feasible performance. The proposed method utilizes the partitions of the memory space by utilizing threshold values and reconfigures the management units if necessary. The performance of the proposed policies is evaluated through a number of simulation based experiments.

A scintillation detector configuration for pulse shape analysis

  • Van Chuan, Phan;Hoa, Nguyen Duc;Hai, Nguyen Xuan;Anh, Nguyen Ngoc;Dien, Nguyen Nhi;Khang, Pham Dinh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1426-1432
    • /
    • 2018
  • This paper presents a neutron detector configuration using EJ-301 scintillation liquid, a R9420 photo-multiplier and a homemade preamplifier. The detector qualities which include the energy linearity, efficiency response and neutron/gamma discrimination are guaranteed for neutron detection in the energy range from 0 to 3000 keVee. Regarding the neutron/gamma discrimination capability, four pulse shape discrimination (PSD) methods which are the threshold crossing time (TCT), pulse gradient analysis (PGA), charge comparison (CC) and correlation pattern recognition (CPR), were evaluated and discussed; among of these, the CPR method provides the best neutron/gamma discrimination.

A Comparative Study of Insert Earphones and Circumaural Earphones in the Brainstem Auditory-Evoked Response Test of Dogs

  • Kim, Sang-Woo;Song, Joong-Hyun;An, Su-Jin;Yu, Do-Hyeon;Kim, Young Joo;Han, Donghyun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.123-129
    • /
    • 2020
  • We aimed to investigate the differences in the efficacy of insert and circumaural earphones when performing the brainstem auditory evoked response (BAER) test with dogs. Hearing loss may occur congenitally or secondarily in dogs. The BAER test, unlike the classical ethological method, is the most reliable diagnostic tool to assess canine auditory function. Furthermore, there are certain advantages of using insert earphones rather than the standard, circumaural earphones. We subjected eight dogs to the BAER test with insert earphones and circumaural earphones. The result revealed that the latency of waves was delayed with an insert earphone. The inter-peak latency did not show any significant differences between the two transducers, and the threshold was higher when using an insert earphone. Moreover, the circumaural headphones produced a greater degree of crossover effect than the insert earphones, and this cross-over effect could affect the outcomes of the BAER test. Considering these results, we concluded that insert earphones may be more appropriate when performing the canine BAER test.

Investigation of mode identifiability of a cable-stayed bridge: comparison from ambient vibration responses and from typhoon-induced dynamic responses

  • Ni, Y.Q.;Wang, Y.W.;Xia, Y.X.
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.447-468
    • /
    • 2015
  • Modal identification of civil engineering structures based on ambient vibration measurement has been widely investigated in the past decades, and a variety of output-only operational modal identification methods have been proposed. However, vibration modes, even fundamental low-order modes, are not always identifiable for large-scale structures under ambient vibration excitation. The identifiability of vibration modes, deficiency in modal identification, and criteria to evaluate robustness of the identified modes when applying output-only modal identification techniques to ambient vibration responses were scarcely studied. In this study, the mode identifiability of the cable-stayed Ting Kau Bridge using ambient vibration measurements and the influence of the excitation intensity on the deficiency and robustness in modal identification are investigated with long-term monitoring data of acceleration responses acquired from the bridge under different excitation conditions. It is observed that a few low-order modes, including the second global mode, are not identifiable by common output-only modal identification algorithms under normal ambient excitations due to traffic and monsoon. The deficient modes can be activated and identified only when the excitation intensity attains a certain level (e.g., during strong typhoons). The reason why a few low-order modes fail to be reliably identified under weak ambient vibration excitations and the relation between the mode identifiability and the excitation intensity are addressed through comparing the frequency-domain responses under normal ambient vibration excitations and under typhoon excitations and analyzing the wind speeds corresponding to different response data samples used in modal identification. The threshold value of wind speed (generalized excitation intensity) that makes the deficient modes identifiable is determined.

The Scalability and the Strategy for EMR Database Encryption Techniques

  • Shin, David;Sahama, Tony;Kim, Steve Jung-Tae;Kim, Ji-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.577-582
    • /
    • 2011
  • EMR(Electronic Medical Record) is an emerging technology that is highly-blended between non-IT and IT area. One of methodology to link non-IT and IT area is to construct databases. Nowadays, it supports before and after-treatment for patients and should satisfy all stakeholders such as practitioners, nurses, researchers, administrators and financial department and so on. In accordance with the database maintenance, DAS (Data as Service) model is one solution for outsourcing. However, there are some scalability and strategy issues when we need to plan to use DAS model properly. We constructed three kinds of databases such as plain-text, MS built-in encryption which is in-house model and custom AES (Advanced Encryption Standard) - DAS model scaling from 5K to 2560K records. To perform custom AES-DAS better, we also devised Bucket Index using Bloom Filter. The simulation showed the response times arithmetically increased in the beginning but after a certain threshold, exponentially increased in the end. In conclusion, if the database model is close to in-house model, then vendor technology is a good way to perform and get query response times in a consistent manner. If the model is DAS model, it is easy to outsource the database, however, some technique like Bucket Index enhances its utilization. To get faster query response times, designing database such as consideration of the field type is also important. This study suggests cloud computing would be a next DAS model to satisfy the scalability and the security issues.

Risk Assessment of Escherichia coli Infection from Use of Interactive Waterscape Facilities (수경시설 물놀이에 따른 대장균 감염의 위해도 분석)

  • Zo, Young-Gun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.73-81
    • /
    • 2012
  • Objectives: With the goal of quantifying the risk of children contracting gastroenteritis while playing at interactive waterscape facilities and evaluating the adequacy of current water quality regulations, risk assessment was performed with Escherichia coli as pathogen. Methods: Abundances of E. coli in the waters of interactive water features in South Korea were acquired from survey reports. A gamma distribution describing the volume of water swallowed by children during swimming activities was adopted. Exposure rate and risk were calculated by Monte Carlo simulation and dose-response models for various pathogenic E. coli. Results: E. coli was detected in 25 out of 40 facilities, with range of ~1,600 CFU/100 ml. The abundance fitted an exponential distribution. Simulated exposures ranged ${\sim}1.9{\times}10^{10}$ CFU, varying greater along E. coli abundance than the volume of water. Risk of children being infected by enterohemorrhagic E. coli was high, with range of ~0.85. When E. coli abundance was <200 CFU/100 ml, which is the current government threshold, the risk decreased to <0.43. Although the guideline successfully reduced the risk of adults being infected by a less virulent E. coli strains (<0.03), the risk for children could not be quantified due to lack of dose-response models for those pathogens for children. Conclusions: Under the current guideline, children are at risk of being infected if water is contaminated with by enterohemorrhagic E. coli. For other E. coli strains, the risk appears to be considerably less. The result warrants need for developing dose-response models for children for each pathogenic E. coli strain.

The role background noise intensity on Physiological activity during performance of mental task (인지과제 수행시 배경 소음의 크기에 따른 생리적 반응차)

  • Sohn Jin-Hun;Sokhadze Estate M.;Min Yoon-Ki;Lee Kyung-Hwa;Choi Sangsup
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.269-273
    • /
    • 1999
  • Combination of mental stress task with noise background is a traditional tool employed in psychophysiology. However, intensity of background noise is a factor affecting both performance on test and psychophysiological responses associated with stress evoked by mental load in noisy environment. In the current study on 7 subjects we analyzed the influence of white noise (WN) intensity (55, 70, and 85 dB[A] ) on psychophysiological responses during word recognition test performed on noise background. There were recorded following physiological variables: electrodermal activity (EDA) , namely, skin conductance level (SCL), skin conductance response (SCR) amplitude (SCR-A), rise time and total number of SCRs (N-SCR); cardiovascular activity, e.g., heart rate (HR), respiratory sinus arrhythmia (RSA) index, pulse transit time (PTT), finger pulse volume (PV), skin temperature (SKT) and respiratory activity, such as respiration rate (RESP-R) and inspiration wane amplitude (RESP-A) during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different WN intensity (55, 70, and 85 dB). Electrodermal responses (SCR-A, SCL, N-SCR) demonstrated gradual increment with increased intensity of noise, and this increase of response magnitude with higher intensity of noise was typical also for r skin temperature (phasic SKT decrease) and pulse volume (phasic and tonic PV decrease). However, some cardiovascular and respiratory responses did not exhibit same tendency of gradual increase of reactivity , namely HR, as well as RESP-R and RESP-A showed decrement of response magnitudes. Important finding in terms of cardiovascular reactivity was that 55 and 70dB evoked similar profiles, while 85dB WN resulted in significantly different profile of reactions, suggesting that there exists a threshold level after which intensive auditory stimulation elicits psychophyslological responses pattern of different quality. There are discussed potential autonomic mechanism involved in mediation of observed physiological responses.

  • PDF