• Title/Summary/Keyword: Response Rate

Search Result 5,493, Processing Time 0.028 seconds

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

Assessment of Corrosion Rate of Reinforcing Steel in Concrete Using Galvanostatic Pulse Transient Technique

  • So, Hyoung-Seok;Millard, Stephen Geoffrey
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.83-88
    • /
    • 2007
  • This paper discusses a method of measuring transient potential response of a corrosion interface to a small galvanostatic pulse perturbation for a rapid assessment of the corrosion rate of reinforcing steel in concrete structures. Measurements were taken on 100 mm sections of steel bars which were subjected to a wide range of corrosion conditions, from passive steel to actively corroding steel. The duration of the applied galvanostatic pulse was varied between 5s and 180s, and the lateral distance of the point of measurement on the steel bar varied from zero to 400 mm. The result of the electrochemical transient response was investigated using a typical sampling rate of 1 kHz. Analysis of the transient potential response to the applied galvanostatic pulse has enabled the separation of equivalent electronic components so that the components of a series of capacitances and resistances, whose values are dependent on the corrosion condition of the reinforcing steel, could be isolated. The corrosion rate was calculated from a summation of the separate resistive components, which were associated with the corrosion interface, and was compared with the corrosion rate obtained from linear polarization resistance (LPR) method. The results show that the galvanostatic pulse transient technique enables the components of the polarization resistance to be evaluated separately so as to give more reliable corrosion rate values than those obtained from the LPR method. Additionally, this paper shows how the galvanostatic pulse transient response technique can be implemented. An appropriate measurement time for passive and actively corroding reinforcing steel is suggested for the galvanostatic pulse transient response measurements in the field site.

A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head (용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구)

  • 이병곤;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

A LAN System Based on the Buffer Insertion Protocol (버퍼 삽입 프로토콜에 의한 LAN시스템에 관한 연구)

  • 권영수;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.1
    • /
    • pp.16-24
    • /
    • 1986
  • The queueing delay and the response time of model of the buffer insertion LAN have been derived and its performance has been analyzed in terms of the throughput rate-response time characteristic. The results show that the response time can be improved by increasing the medium data rate, and that it can be reduced by 0.7 msec by transmitting the acknowledgement signal at the network interface unit(NIU) rather than at the hose, when the channel utilization is approximately 0.8. Also, implementation of the buffer insertion protocol has been studied.

  • PDF

Compaction and Sintering Behaviour of Zirconia Powders: I. Compaction Response (지르코니아 분말의 치밀화와 소결거동 : I. 가압에 따른 치밀화 응답)

  • ;Frank L. Riley
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.6
    • /
    • pp.489-495
    • /
    • 1992
  • The continuous compaction response of zirconia powders prepared by different processing treatments was investigated. Though the yield point could be or not below 1 MPa, the change of slope was always observed at high pressure range around 60 MPa. Powder compaction was mainly governed by second compaction stage and compaction rate was decreased with increasing forming pressure. Rotary vacuum dried powder favored a high compaction density, whereas freeze dried and calcined powders favored an increase in the pressing efficiency. In order to extract more reliable information about powder compaction, it was necessary to use not only compaction response diagram but also compaction rate diagram.

  • PDF

Effects of stimuli and reaction methods on error rate and time of choice reaction (자극의 종류와 반응방법이 선택반응에 미치는 영향에 관한 연구)

  • 장성록
    • Journal of the Ergonomics Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.27-35
    • /
    • 1994
  • Automation and mechanization of work make people put the machine into operation and control the state of operation. In the process of those works they are apt to have accidents caused by their carelessness. To reduce such accidents, we can practice "TOUCH '||'&'||' CALL", which is to indicate and ascertain the dangerous parts at every process before performing tasks. The objectives of this study are to examine the effects of S-R compatibility and to show quantitatively the efficiency of TOUCH '||'&'||' CALL. The results show that: 1. Reaction time in case of indicating with fingers and shouting is slightly longer (0.138sec. .approx. 0.279sec. ) than that of responding only visually. However, the error rate decreases by 1/3.3 .approx. 1/4.2 times. Frome this, it is considered to verify quantitative estimation on multiple feedback of TOUCH '||'&'||' CALL. 2. In the stimulus-response relation aspect, numeric numeric stimulus-numeric response shows lower error rate (0.033% .approx. 0.133%) than any other stimulus-response relation, ahd shorter reaction time is proven ( 0.556sec. .approx. 0.835sec. ). These data suggest that having the order of stimulus-response arranged in accordance with the experimental knowledges and conceptional compatibility can bring down the error rate considerably.

  • PDF

Effect of Acupuncture ST36 on Skin Temperature, Galvanic Skin Response and Heart Rate in Humans (족삼리(足三里) 침자(鍼刺)가 인체(人體)의 Skin temperature, Galvanic skin response 및 Heart rate에 미치는 영향(影響))

  • Youn Dae-Hwan;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.20 no.3
    • /
    • pp.29-34
    • /
    • 2003
  • Objectives : The purpose of this study was to investigate the Effect of Acupuncture Chok-samni(ST36) on Skin temperature(ST), Galvanic skin response(GSR) and Heart rate(HR) in humans. ST36 is used in uneasiness, high fever, stroke, paralysis on oriental medicine. Methods : Subjects were 18 healthy oriental medical students volunteers(15male, 3female, mean age-28). Under sequence of ST36 acupuncture, the first group was observed ST, the second group was observed GSR and the third group was observed HR. Skin temperature was measured on Haegye acupoint(ST41) before and after acupuncture stimulation. Each test took 15minutes. This test was performed twice in order to increase the statistical authenticity. Results : Our result indicates that acupuncture stimulation of ST36 statistically decreased skin temperature on ST41. Also statistically decreased in HR. The change of GSR after ST36 acupuncture was decreased, but there is no statistical. Conclusions : These results suggested that acupuncture stimulation of ST 36 has effect on ST and HR in human body, and may be used by treatment as control the nerve system.

  • PDF

A Study on Flow Rate Characteristic and Dynamic Performance on Diaphragm Solenoid Valve (다이어프램형 밸브의 유량특성과 동적성능에 관한 연구)

  • Jeong, C.S.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.3
    • /
    • pp.27-33
    • /
    • 2013
  • Solenoid valve has used in various industrial field extensively. A solenoid valve has different size, shape and method of operation accordantly to industrial field. Many researchers study on kinds of solenoid valve such as flow rate, dynamic, magnetic field, valve shape and operating method. But the flow rate characteristic and dynamic response time performance on the diaphragm valve are not studied. This paper describes the flow rate characteristic and dynamic response time performance on the diaphragm valve. At first, the diaphragm valve is simulated in AMESim simulation tool. AMESim model found that an effect of valve performance depends on parameter. The parameter is the diaphragm orifice area. And the performance test bench confirms the effect in this parameter. Finally, it finds out the flow rate characteristic and dynamic response time performance on the diaphragm valve.

Yaw Moment Control for Modification of Steering Characteristic in Rear-driven Vehicle with Front In-wheel Motors (전륜 인휠모터 후륜구동 차량의 선회 특성 변형을 위한 요모멘트 제어)

  • Cha, Hyunsoo;Joa, Eunhyek;Park, Kwanwoo;Yi, Kyongsu;Park, Jaeyong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.1
    • /
    • pp.6-13
    • /
    • 2021
  • This paper presents yaw moment control for modification of steering characteristic in rear-driven vehicle with front in-wheel motors (IWMs). The proposed control algorithm is designed to modify yaw rate response of the test vehicle. General approach for modification of steering characteristic is to define the desired yaw rate and track the yaw rate. This yaw rate tracking method can cause the chattering problem because of the IWM actuator response. Large overshoot and settling time in IWM torque response can amplify the oscillation in control input and yaw rate. To resolve these problems, open-loop IWM controller for cornering agility was designed to modify the understeer gradient of the vehicle. The proposed algorithm has been investigated via the computer simulations and the vehicle tests. The performance evaluation has been conducted on dry asphalt using E-segment test vehicle. The performance of the proposed algorithm has been compared to general yaw rate tracking algorithm in the vehicle tests. It has been shown that the proposed control law improved the cornering agility without chattering problem.

Trans-arterial Chemo-Embolization in Treating Elderly Patients with Hepatocellular Carcinoma

  • Zhang, Jian-Feng;Liu, Jun-Mao;Zhang, Nin;Du, Chao;Zheng, Qin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7201-7204
    • /
    • 2015
  • Background: This analysis was conducted to evaluate the efficacy and safety of Trans-arterial Chemo-Embolization (TACE) in treating Elderly patients with Hepatocellular Carcinoma (EHPC). Methods: Clinical studies evaluating the efficacy and safety of TACE on response and safety for patients with EHPC were identified by using a predefined search strategy. Pooled response rate of treatment were calculated. Results: In TACE based regimen, clinical studies which including patients with EHPC were considered eligible for the evaluation of response. And, in these TACE based treatments, pooled analysis suggested that, in all 288 patients whose response could be assessed, the pooled reponse rate was 29.5%(85/288) in TACE based treatment. The most commonly encountered TACE-related morbidity was liver function impairment. No grade III or IV renal or liver toxicity were observed. No treatment related death occurred in EHPC patients with TACE based treatments. Conclusion: This evidence based analysis suggests that TACE based treatments are associated with mild response rate and accepted toxicities for treating patients with EHPC.