• Title/Summary/Keyword: Respiratory rate check

Search Result 19, Processing Time 0.021 seconds

A Study on the morbid status of a rural area and comparison of its study methodology (일부(一部) 농촌주민(農村住民)의 상병현황조사(傷病現況調査)와 조사기법(調査技法)의 비교연구(比較硏究))

  • Lee, Eun-Il;Min, Jae-Gee;Song, Dong-Bin
    • Journal of agricultural medicine and community health
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 1984
  • This research was done to gain the health information in one of the target areas(rural area) of the Korea University Community Health Project, and to improve and standardize the methodology of the health interview survey. There were two types of questions;one was the simple open-ended question and the other was check list in the interview survey for a total of 1,406 inhabitants. And so the result obtained from the above survey was analysed. The results as follows; 1) The morbidity rate in general was 11.2% by simple open-ended question and 32.5% by check list during recent 20 days in interview method. 2) Women had higher morbidity rate in both kinds of method. 3) The most prevalent diseases in the interview method using check list were the ones of the musculo-skeletal system and connective tissue (22.5%), and diseases of the respiratory system (19.8%) and digestive system (13.7%) were in order of frequency. 4) By the position in the family, housewives had highest morbidity rate in the interview method unrespectedly, and the reason seemed that the respondents were houseweives themselves and the morbidity rate was the one by spell not by person. But morbidity rate by the socio-economic status had no significant difference in both methods. 5) The agreement rate on simple open-ended question and check list was 72.5%, but if limiting respondents themselves only, the rate was falled to 54%. 6) The morbidities were diverse in the review of the results of previous morbidity surveies, but the morbidity rate was higher and less variable in case of using check list and getting the replies individually than using simple open-ended question and proxy respondents.

  • PDF

Characteristics of Individuals Seeking Comprehensive Health Check-ups (종합 건강검진을 원하는 피검진자의 건강특성에 관한 연구)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.3
    • /
    • pp.563-576
    • /
    • 1997
  • This study was carried out to identify basic data for more efficient operation of comprehensive health check-up centers in the national health care system. The researcher reviewed and analyzed the main symptoms of the subjects according to sex, age, occupation and positive rate in the screening tests of a comprehensive health check-up, performed at one comprehensive health check-up center in located in a hospital. The subjects were 512 persons who had a check-up at the comprehensive health check-up, center in K university hospital in Seoul from October 2, 1996 to March 30, 1997. A questionaire developed by the researcher to obtain subject's general characteristics, main symptoms, medical examination, diagnosed disease was used as the tool for the study. The researcher analyzed the data with SPSS PC/sup +/ program. : the distribution of the subject's general characteristics and main symptoms was described with percentages and the difference between main symptoms and screening tests analyzed with X²-test, t-test, ANOVA. The result of this study are as follows : 1. For the distribution of diagnosis in males. liver disease was most frequent and hypertension was second : in females, hypertention and liver disease were not common in that order. 2. The most common complaints were indigestion in the digestive system, sputum in the respiratory system, irregular heart beat in the cardiovascular system, frequent urine in the urinary system vertigo in the hematologic system. 3. The main symptoms according to sex were for females, a statistically siguificant higher rate of complaints in the digestive system, cardiovascular system, urinary system, hematologic system, musculoskeletal, mental & nervous system as compared to males. 4. The main symptoms according to age were that in the the second decade there wara higher rate of complaints in the digestive system, and cardiovascular system than in the older age groups : and in the fifth decade more in the musculoskeletal system. 5. The main symptoms according to occupation were that formers and fishers had a higher rate of complaints in the mental and nervous system as compared to other occupation groups : and office workers, in gynecology. 6. The main symptoms according to diagnosis, were symptoms of the digestive system, frequent in liver disease : symptoms of the cardiovascular system in allergic disease. 7. The screening tests which showed the highest rates were UGI /FGS, PFT : In males a higher rate of abnormality was seen in abdominal ultrasono- graphy and in, females, in mammography. 8. In screening tests according to sex, males showed a higher positive rate for chest X-rays, and LFT, and females, in mammography, pap smear, CBC. 9. In screening tests according to age, higher positive rates of obesity, high blood pressure, chest X-ray, mammography, pap smear, FBS, CBC, urine test were seen in the fifth decade : PFT and abdominal ultrasonography in the third decade. The subjects who wanted comprehensive health check-up were not asymptomatic but had an illness with several symptoms. It is found that the most frequent diagnosed diseases were hypertention and liver disease. So proper observations must be done for them. Comprehensive health check-ups should be changed to a comprehensive examination including treatment beyond examination for those subjects with positive results.

  • PDF

Respiration and Heartbeat detection algorithm using UWB radar (UWB 레이더를 사용한 호흡 및 심박 감지 알고리즘)

  • Le, Minhhuy;Hwang, Lan-mi;Fedotov, Dmitry
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2019
  • Ultra Wideband (UWB) Radar is a high-resolution radar for short distance detection which uses signals transmitted and received by each antennas in order to detect a target. It is possible to detect the respiration and heartbeat of a person without contact It is getting more and more often utilized since it is not affected by physical environment. In this paper, we implement an algorithm to detect human respiration and heartbeat rate using UWB radar signal. We process radar signals reflected from human body using Median filter, Kalman filter, Band Pass filter and so on. We also use CZT to extract breathing and heart rate. ECG (Electrocardiogram) was used for comparison of heartbeat data and we confirm that each data of ECG and UWB Radar were more than 98% identical each other.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

Analysis of ROX Index, ROX-HR Index, and SpO2/FIO2 Ratio in Patients Who Received High-Flow Nasal Cannula Oxygen Therapy in Pediatric Intensive Care Unit (고유량 비강 캐뉼라 산소요법을 받은 소아중환자실 환아의 ROX Index와 ROX-HR Index 및 SpO2/FIO2 Ratio분석)

  • Choi, Sun Hee;Kim, Dong Yeon;Song, Byung Yun;Yoo, Yang Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.53 no.4
    • /
    • pp.468-479
    • /
    • 2023
  • Purpose: This study aimed to evaluate the use of the respiratory rate oxygenation (ROX) index, ROX-heart rate (ROX-HR) index, and saturation of percutaneous oxygen/fraction of inspired oxygen ratio (SF ratio) to predict weaning from high-flow nasal cannula (HFNC) in patients with respiratory distress in a pediatric intensive care unit. Methods: A total of 107 children admitted to the pediatric intensive care unit were enrolled in the study between January 1, 2017, and December 31, 2021. Data on clinical and personal information, ROX index, ROX-HR index, and SF ratio were collected from nursing records. The data were analyzed using an independent t-test, χ2 test, Mann-Whitney U test, and area under the curve (AUC). Results: Seventy-five (70.1%) patients were successfully weaned from HFNC, while 32 (29.9%) failed. Considering specificity and sensitivity, the optimal cut off points for predicting treatment success and failure of HFNC oxygen therapy were 6.88 and 10.16 (ROX index), 5.23 and 8.61 (ROX-HR index), and 198.75 and 353.15 (SF ratio), respectively. The measurement of time showed that the most significant AUC was 1 hour before HFNC interruption. Conclusion: The ROX index, ROX-HR index, and SF ratio appear to be promising tools for the early prediction of treatment success or failure in patients initiated on HFNC for acute hypoxemic respiratory failure. Nurses caring for critically ill pediatric patients should closely observe and periodically check their breathing patterns. It is important to continuously monitor three indexes to ensure that ventilation assistance therapy is started at the right time.

Inappropriate Peak Inspiratory Flow Rate in the Patients with Stable Chronic Obstructive Pulmonary Disease in Korea

  • Seong Hwan Youn;Hyun Jung Kim;Jae Seok Park;Sun Hyo Park;Yong Shik Kwon;Mi-Ae Kim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.4
    • /
    • pp.458-464
    • /
    • 2024
  • Background: While inhalation therapy efficacy hinges on attaining proper peak inspiratory flow rate (PIFR), the prevalence of inappropriate PIFR among patients with chronic obstructive pulmonary disease (COPD) remains unstudied in Korea. This study aimed to assess the prevalence of inappropriate PIFR, its correlation with COPD assessment test (CAT) scores, and factors associated with suboptimal PIFR. Methods: We enrolled 108 patients with COPD who had been using the same inhaler for at least 1 year without exacerbations. PIFR was measured using an inspiratory flow meter (In-Check DIAL G16). Demographic, clinical, pulmonary function, and CAT score data were collected. Inappropriate was defined as PIFR <60 L/min for dry power inhaler (DPI) users, and >90 L/min for aerosol device users. Results: The cohort comprised 87 (80.6%) men, mean age 71.0±8.5 years, with mean post-bronchodilator forced expiratory volume in 1 second of 69.1%±1.8% predicted. Twenty-nine (26.9%) used aerosol devices only, 76 (70.4%) used DPIs only, and three (2.8%) used both. Inappropriate PIFRs were found in 17.2% of aerosol device users, and 42.1% of DPI users. CAT scores were significantly higher in the inappropriate PIFR group than in the appropriate PIFR group (11.2±7.7 vs. 7.5±4.9, p=0.003). In DPI users, female, shorter height, lower body weight and maximal voluntary ventilation (MVV) were associated with inappropriate PIFR. Conclusion: The prevalence of inappropriate PIFR among patients with COPD is 17.2% for aerosol device users, and 42.1% for DPI users. Suboptimal PIFR correlates with female gender, shorter stature, lower weight and MVV in DPI users.

Adsorption Properties of Cellular Light-weight Concrete using Rice Husks (왕겨숯을 이용한 경량기포콘크리트의 흡착 특성)

  • Lee, Chang-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.146-147
    • /
    • 2021
  • An increase in carbon emissions leads to the problem of global warming and is an issue to be solved in other countries. The problem of carbon dioxide has many effects not only on global warming but also on people. According to the World Health Organization (WHO), 4.3 million people have died because harmful substances generated indoors cannot be discharged to the outside and accumulate in the human body through the respiratory tract. In response to this situation, in order to reduce the generation of pollutants in the building itself, soak into lightweight bubble concrete to adsorb and purify indoor pollutants, mix charcoal, investigate the appropriate amount and physical characteristics, and check carbon dioxide This is an experiment for grasping the adsorption capacity, and the results are as follows. As the replacement rate of rice husk charcoal increased, the compressive strength tended to decrease, and the carbon dioxide reduction rate tended to increase. It is judged that the charcoal of rice husks shows a low density and the physical adsorption is smooth due to the porous structure. Since it is excellent in the basic physical properties and carbon dioxide adsorption surface of this experiment, it is judged that it has sufficient potential for use as an indoor finishing material.

  • PDF

Health Problem of the Middle-Aged Women (종합 건강검진 과정에서 나타난 일부 중년기 여성의 건강문제)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.258-270
    • /
    • 1999
  • This study was carried out to offer the basic data for more qualitative lives of the middle-aged women through their health maintenance and control. So, the researcher reviewed and analyzed the health problems of the middle-aged women, the differences of main symptoms in each subject, positive ratcs in screening tests, the difference of screening tests with age and the correlation of obesity and blood pressure with screening tests. All subjects were 218 women(40-59years) who had a check-up at a comprehensive health check-up center in K University Hospital in Seoul from July 1, 1998 to August 31. 1998. Questionaires were developed to get subjects, general characteristics. main symptoms, medical examination and diagnosed disease by the researcher referring through the questionaires of comprehensive health check-up center and the medical recorders were used as a tool of study. The researcher analyzed the data with SPSS PC+ ; the distribution of the subjects, general characteristics and main symptoms with percentage : the difference between main symptoms and screening tests with X$^2$-test, ANOVA. The results are as follows. 1) Among the age distribution, most were 40-45 years old and unemployed. 2) The most common complaints were indigestion in digestive system, cough in respiratory system, heart beat in cardiovascular system, general sweat in endocrine system. edema in urinary system, easy bruise in hematologic system, backache in musculoskeletal system, headache in psychoneurologic system, lochia in gynecology, itch in dermatology system, eye ball pain in visual system and tinnitus in auditory system. 3) In main symptoms according to age, the 40-45 age group had a higher rate of complaints in digestive system and gynecology than other age group ; the 46-49 age group in endocrine system. 4) The main symptoms according to diagnosis had no difference statistically. 5) The screening tests which showed high rates of abnormality were mammography(the highest), abdominal ultrasonography, upper gastrointestinal series/gastrofiberscopy, PFT. In all age group the highest rate of abnormality was seen in mammography. 6) In screening tests according to age. the 46-49 age group showed higher positive rates of pap smear, blood sugar test, urine test than any other age group ; the 50-55 age group showerd higher positive rates of obesity, BP, chest X-ray, abdominal ultrasonography, ESR, SGOT, CRP and urine micro. 7) In correlation of obesity with screening test, the obesity group showed higher positive rates of blood pressure, chest X-ray, abdominal ultrasonography, HCT and CRP than the normal weight group. 8) In correlation of blood pressure with screening test, the hypertension group showed higher positive rate of obesity, chest X-ray, abdominal ultrasonography, pap smear and blood sugar than the normal blood pressure group. In conculusion, the middle-aged women have various physical symptoms and affected by age. The obesity and BP have an important effect on the health of the middle aged women. Therefore, this study is considered significant as data for qualitative lives of the middle-aged women playing an important part of family health care by catching of their health problem complaints for prevention of disease and promotion of health.

  • PDF

A Remote Rehabilitation System using Kinect Stereo Camera (키넥트 스테레오 영상을 이용한 원격 재활 시스템)

  • Kim, Kyungah;Chung, Wan-Young;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.196-201
    • /
    • 2016
  • Rehabilitation exercises are the treatments designed to help patients who are in the process of recovery from injury or illness to restore their body functions back to the original status. However, many patients suffering from chronic diseases have found difficulties visiting hospitals for the rehabilitation program due to lack of transportation, cost of the program, their own busy schedules, etc. Also, the program usually contains a few medical check-ups which can cause patients to feel uncomfortable. In this paper, we develop a remote rehabilitation system with bio-signals by a stereo camera. A Kinect stereo camera manufactured by Microsoft corporation was used to recognize the body movement of a patient by using its infrared(IR) camera. Also, we detect the chest area of a user from the skeleton data and process to gain respiratory status. ROI coordinates are created on a user's face to detect photoplethysmography(PPG) signals to calculate heart rate values from its color sensor. Finally, rehabilitation exercises and bio-signal detecting features are combined into a Windows application for the cost effective and high performance remote rehabilitation system.