• Title/Summary/Keyword: Respiratory Sound Classification

Search Result 8, Processing Time 0.021 seconds

Parallel Network Model of Abnormal Respiratory Sound Classification with Stacking Ensemble

  • Nam, Myung-woo;Choi, Young-Jin;Choi, Hoe-Ryeon;Lee, Hong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.11
    • /
    • pp.21-31
    • /
    • 2021
  • As the COVID-19 pandemic rapidly changes healthcare around the globe, the need for smart healthcare that allows for remote diagnosis is increasing. The current classification of respiratory diseases cost high and requires a face-to-face visit with a skilled medical professional, thus the pandemic significantly hinders monitoring and early diagnosis. Therefore, the ability to accurately classify and diagnose respiratory sound using deep learning-based AI models is essential to modern medicine as a remote alternative to the current stethoscope. In this study, we propose a deep learning-based respiratory sound classification model using data collected from medical experts. The sound data were preprocessed with BandPassFilter, and the relevant respiratory audio features were extracted with Log-Mel Spectrogram and Mel Frequency Cepstral Coefficient (MFCC). Subsequently, a Parallel CNN network model was trained on these two inputs using stacking ensemble techniques combined with various machine learning classifiers to efficiently classify and detect abnormal respiratory sounds with high accuracy. The model proposed in this paper classified abnormal respiratory sounds with an accuracy of 96.9%, which is approximately 6.1% higher than the classification accuracy of baseline model.

Classification of Normal Subjects and Pulmonary Function Disease Patients using Tracheal Respiratory Sound Detection System (기관 호흡음 검출 시스템을 이용한 정상인과 폐기능 질환자의 분류)

  • Im, Jae-Jung;Lee, Yeong-Ju;Jeon, Yeong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.220-224
    • /
    • 2000
  • A new auscultation system for the detection of breath sound form trachea was developed in house. Small size microphone(panasonic pin microphone) was encapsuled in a housing for resonant effect, and hardware for the sound detection was fabricated. Pulmonary function test results were compared with the parameters extracted from frequency spectrum of breath sound obtained from the developed system. Results showed that the peak frequency and relative ratio of integral values between low(80∼400Hz) and high(400∼800Hz) frequency ranges revealed the significant differences. Developed system could be used for distinguishing normal subject and the patients who have pulmonary disease.

  • PDF

Noise-Robust Porcine Respiratory Diseases Classification Using Texture Analysis and CNN (질감 분석과 CNN을 이용한 잡음에 강인한 돼지 호흡기 질병 식별)

  • Choi, Yongju;Lee, Jonguk;Park, Daihee;Chung, Yongwha
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.3
    • /
    • pp.91-98
    • /
    • 2018
  • Automatic detection of pig wasting diseases is an important issue in the management of group-housed pigs. In particular, porcine respiratory diseases are one of the main causes of mortality among pigs and loss of productivity in intensive pig farming. In this paper, we propose a noise-robust system for the early detection and recognition of pig wasting diseases using sound data. In this method, first we convert one-dimensional sound signals to two-dimensional gray-level images by normalization, and extract texture images by means of dominant neighborhood structure technique. Lastly, the texture features are then used as inputs of convolutional neural networks as an early anomaly detector and a respiratory disease classifier. Our experimental results show that this new method can be used to detect pig wasting diseases both economically (low-cost sound sensor) and accurately (over 96% accuracy) even under noise-environmental conditions, either as a standalone solution or to complement known methods to obtain a more accurate solution.

Classification of Porcine Wasting Diseases Using Sound Analysis

  • Gutierrez, W.M.;Kim, S.;Kim, D.H.;Yeon, S.C.;Chang, H.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.8
    • /
    • pp.1096-1104
    • /
    • 2010
  • This bio-acoustic study was aimed at classifying the different porcine wasting diseases through sound analysis with emphasis given to differences in the acoustic footprints of coughs in porcine circo virus type 2 (PCV2), porcine reproductive and respiratory syndrome (PRRS) virus and Mycoplasma hyopneumoniae (MH) - infected pigs from a normal cough. A total of 36 pigs (Yorkshire${\times}$Landrace${\times}$Duroc) with average weight ranging between 25-30 kg were studied, and blood samples of the suspected infected pigs were collected and subjected to serological analysis to determine PCV2, PRRS and MH. Sounds emitted by coughing pigs were recorded individually for 30 minutes depending on cough attacks by a digital camcorder placed within a meter distance from the animal. Recorded signals were digitalized in a PC using the Cool Edit Program, classified through labeling method, and analyzed by one-way analysis of variance and discriminant analysis. Input features after classification showed that normal cough had the highest pitch level compared to other infectious diseases (p<0.002) but not statistically different from PRRS and MH. PCV2 differed statistically (p<0.002) from the normal cough and PRRS but not from MH. MH had the highest intensity and all coughs differed statistically from each other (p<0.0001). PCV2 was statistically different from others (p<0.0001) in formants 1, 2, 3 and 4. There was no statistical difference in duration between different porcine diseases and the normal cough (p>0.6863). Mechanisms of cough sound creation in the airway could be used to explain these observed acoustic differences and these findings indicated that the existence of acoustically different cough patterns depend on causes or the animals' respiratory system conditions. Conclusively, differences in the status of lungs results in different cough sounds. Finally, this study could be useful in supporting an early detection method based on the on-line cough counter algorithm for the initial diagnosis of sick animals in breeding farms.

Development of KPCS(Korean Patient Classification System for Nurses) Based on Nursing Needs (간호요구 정도에 기초한 한국형 환자분류도구(KPCS)의 개발)

  • Song, Kyung Ja;Kim, Eun Hye;Yoo, Cheong Suk;Park, Hae Ok;Park, Kwang Ok
    • Journal of Korean Clinical Nursing Research
    • /
    • v.15 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • Purpose: This study was to develop a factor-type patient classification system for general nursing unit based on nursing needs (KPCS; Korean patient classification system for nurses). Method: We reviewed workload management system for nurses(WMSN) of Walter Reed Medical Center, Korean patient classification system for ICU, and nursing activities in nursing records and developed the first version of KPCS. The final version KPCS was evaluated via validity and reliability verifications based on panel discussions and data from 800 patient classifications. Content validity was performed by Delphi method and concurrent validity was verified by the correlation of two tools (r=.71). Construct validity was also tested by medical department (p<.001), patient type (p<.001), and nurse intuition (p<.001). These verifications were performed from April to October, 2008. Results: The KPCS has 75 items in classifying 50 nursing activities, and categorized into 12 different nursing area (measuring vital sign, monitoring, respiratory treatment, hygiene, diet, excretion, movement, examination, medication, treatment, special treatment, and education/emotional support). Conclusion: The findings of the study showed sound reliability and validity of KPCS based on nursing needs. Further study is mandated to refine the system and to develop index score to estimate the necessary number of nurses for adequate care.

Validity of Nursing Diagnoses Related to Difficulty in Respiratory Function (호흡기능장애와 관련된 간호진단의 타당도 조사)

  • 김조자;이원희;유지수;허혜경;김창희;홍성경
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.569-584
    • /
    • 1993
  • This study was done to verify validity of nursing diagnoses related to difficulty in respiratory function. First, content validity was examined by an expert group considering the etiology and the signs / symptoms of three nursing diagnoses - ineffective airway clearance, ineffective breathing pattern, impaired gas exchange. Second, clinical validity was examined by comparing the frequencies of the etiologies and signs / symptoms of the three nursing diagnoses in clinical case studies with the results of the content validity. This study was a descriptive study. The sample consisted of 23 experts (professors, head nurses and clinical instructors) who had had a variety of experiences using nursing diagnoses in clinical practice, and 102 case reports done by senior student nurses of the college of nursing of Y-university. These reports were part of their clinical practice in the ICU. The instrument used for this study was a checklist for etiologies and signs and symptoms based on the literature, Doenges and Moorhouse (1988), Kim, McFarland, McLane (1991), Lee Won Hee et al. (1987), Kim Cho Ja et at. (1988). The data was collected over four month period from May 1992 to Aug. 1992. Data were analyzed using frequencies done with the SPSS / PC+ package. The results of this study are summarized as follows : 1. General Characteristics of the Expert Group A bachelor degree was held by 43.5% and a master or doctoral degree by 56.5% of the expert group. The average age of the expert group was 35.3 years. Their average clinical experience was 9.3 years and their average experience in clinical practice was 5.9 years. The general characteristics of the patients showed that there were more women than men, that the age range was from 1 to over 80. Most of their medical diagnoses were diagnoses related to the respiratory. system, circulation or neurologic system, and 50% or more of them had a ventilator with intubation or a tracheostomy. The number of cases for each nursing diagnoses was : · Ineffective airway clearance, 92 cases. · Ineffective breathing pattern, 18 cases. · Impaired gas exchange, 22 cases. 2. The opinion of the expert group as to the classification of the etiology, and signs and symptoms of the three nursing diagnoses was as follows : · In 31.8% of the cases the classification of etiology was clear. · In 22.7%, the classification of signs and symptoms was clear. · In 17.4%, the classification of nursing interventions was clear. 3. In the expert group 80% or mere agreed to ‘dysp-nea’as a common sign and symptom of the three nursing diagnoses. The distinguishing signs and symptoms of (Ineffective airway clearance) were ‘sputum’, ‘cough’, ‘abnormal respiratory sounds : rales’. The distinguishing sings and symptoms of (Ineffective breathing pattern) were ‘tachypnea’, ‘use of accessory muscle of respiration’, ‘orthopnea’ and for (Impaired gas exchange) it was ‘abnormal arterial blood gas’, 4. The distribution of etiology, and signs and symptoms of the three nursing diagnoses was as follows : · There was a high frequency of ‘increased secretion from the bronchus and trachea’ in both the expert group and the case reports as the etiology of ineffective airway clearance. · For the etiologies for ineffective breathing pat-tern, ‘rain’, ‘anxiety’, ‘fear’, ‘obstructions of the tract, ca and bronchus’ had a high ratio in the ex-pert group and ‘decreased expansion of lung’ in the case reports. · For the etiologies for impaired gas exchanges, ‘altered oxygen -carrying capacity of the blood’ and ‘excess accumulation of interstitial fluid in lung’ had a high ratio in the expert group and ‘altered oxygen supply’ in the case reports. · For signs and symptoms for ineffective airway clearance, ‘dyspnea’, ‘altered amount and character of sputum’ were included by 100% of the expert group. ‘Abnormal respiratory. sound(rate, rhonchi)’ were included by a high ratio of the expert group. · For the signs and symptoms for ineffective breathing pattern. ‘dyspnea’, ‘shortness of breath’ were included by 100% of the expert group. In the case reports, ‘dyspnea’ and ‘tachypnea’ were reported as signs and symptoms. · For the sign and symptoms for impaired gas exchange, ‘hypoxia’ and ‘cyanosis’ had a high ratio in the expert group. In the case report, ‘hypercapnia’, ‘hypoxia’ and ‘inability to remove secretions’ were reported as signs and symptoms. In summary, the similarity of the etiologies and signs and symptoms of the three nursing diagnoses related to difficulty in respiratory function makes it difficult to distinguish among them But the clinical validity of three nursing diagnoses was established through this study, and at last one sign and symp-tom was defined for each diagnosis.

  • PDF

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF

Surgical Repair for Ebstein's Anomaly (Ebstein 기형의 수술 -2례 보고-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.289-296
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF