• Title/Summary/Keyword: Respiration sensing

Search Result 33, Processing Time 0.021 seconds

A Study on the Possibility of Three-dimensional Wearable Respiration Rate Sensor based on Surface Area Changes (표면적 변화에 기반한 입체적 웨어러블 호흡수 센서의 가능성 탐색)

  • Lee, Seungpyo;Ban, Hyunsung;Lee, Joohyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.35-44
    • /
    • 2018
  • This study suggests the sensing method of the Three-dimensional respiration rate sensor based on surface area changes, and exploring the design direction of the three-dimensional breathing sensor and the design orientation of the garment. To achieve this, two types of three-dimensional respiration rate sensor were produced, and the study of the dummy and the subjects studied. The study I investigated the possibility of measurement of the three-dimensional respiration sensor by the study variables of the sensor type and speed of respiration. The study II proposes a suitable type of sensor for each of the three measuring positions in addition to the study variables in the study I. To evaluate accuracy, reproducibility, and reliability of the three-dimensional respiration rate sensor, the BIOPAC was used to measure the respiration rate simultaneously with the three-dimensional respiration rate sensor. Through all these results of the experiment, it explored the possibility of measurement of the three-dimensional respiration sensor for the dummy. It also proposed a suitable type of sensor by measuring the respiration rate for the human body.

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.

An Implementation of Mobile Respiration Detection Diagnostic System Using Ultrasound Sensing Method (초음파 센싱 방식의 이동형 호흡 측정 진단 시스템의 구현)

  • 김동학;김영길;정승호
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.514-517
    • /
    • 2003
  • Oxygen supply is one of the most basic things in human body. Breathing is controlled by the lungs' stationary function and the respiratory center which is in the mesulla oblongata. Nothing but, the external breathing that air movement between the lungs and atmosphere and the internal breathing that cellular air movement between the hemoglobin and a single cell. The adult's number of times of the respirations is about 15∼20 per 1 minute, but it depends ages, exercise, temperature, disease, etc. The important thing in detecting the respiration is that doing it in object person's resting time. Detecting the respiration have to be done without attracting any attention of object person. In present using method is detecting the pulse with catching an object person's wrist and observing the object person's movement. In this paper, we propose the mobile respiration detection diagnostic system using ultrasound sensing method that does not be influenced by the inertia error and the pressure error.

  • PDF

Miniaturized Sensor Interface Circuit for Respiration Detection System (호흡 검출 시스템을 위한 초소형 센서 인터페이스 회로)

  • Jo, Sung-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.8
    • /
    • pp.1130-1133
    • /
    • 2021
  • In this paper, a miniaturized sensor interface circuit for the respiration detection system is proposed. Respiratory diagnosis is one of the main ways to predict various diseases. The proposed system consists of respiration detection sensor, temperature sensor, and interface circuits. Electrochemical type gas sensor using solid electrolytes is adopted for respiration detection. Proposed system performs sensing, amplification, analog-to-digital conversion, digital signal processing, and i2c communication. And also proposed system has a small form factor and low-cost characteristics through optimization and miniaturization of the circuit structure. Moreover, technique for sensor degradation compensation is introduced to obtain high accuracy. The size of proposed system is about 1.36 cm2.

Application of a Textile-based Inductive Sensor for the Vital Sign Monitoring

  • Gi, Sun Ok;Lee, Young Jae;Koo, Hye Ran;Khang, Seonah;Kim, Kyung-Nam;Kang, Seung-Jin;Lee, Joo Hyeon;Lee, Jeong-Whan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.364-371
    • /
    • 2015
  • In this study, we developed a feasible structure of a textile-based inductive sensor using a machine embroidery method, and applied it to a non-contact type vital sign sensing device based on the principle of magnetic-induced conductivity. The mechanical heart activity signals acquired through the inductive sensor embroidered with conductive textile on fabric were compared with the Lead II ECG signals and with respiration signals, which were simultaneously measured in every case with five subjects. The analysis result showed that the locations of the R-peak in the ECG signal were highly associated with sharp peaks in the signals obtained through the textile-based inductive sensor (r=0.9681). Based on the results, we determined the feasibility of the developed textile-based inductive sensor as a measurement device for the heart rate and respiration characteristics.

A Study on Classification of Halophytes-based Blue Carbon Cover and Estimation of Carbon Respiration Using Satellite Imagery - Targeting the Gwangseok-gil Area in Muan-gun, Jeollanam-do - (위성영상을 이용한 연안지역 염생식물 중심 블루카본 피복 분류 및 탄소호흡량 산정 연구 - 전남 무안군 광석길 일대를 대상으로 -)

  • Park, Jae-Chan;Nam, Jinvo;Kim, Jae-Uk
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.3
    • /
    • pp.1-9
    • /
    • 2024
  • This study aims to estimate the cover classification and carbon respiration of halophytes based on the issues of utilising blue carbon in recent context of climate change. To address the aims, the study classified halophytes(Triglochin maritimum L and Phragmites australis), Intertidal(non-vegetated tidal flats) and Supratidal(sandy tidal flats) to measure carbon respiration and classify cover. The results are revealed that first, the carbon respiration in vegetated areas was less than that in non-vegetated areas. Second, the cover classification could be divided into halophyte communities(Triglochin maritimum L, Phragmites australis), Intertidal and Supratidal by NDWI(Moisture Index, Normalized Difference Water Index) Third, the total carbon respiration of blue carbon was calculated to be -0.0121 Ton km2 hr-1 with halophyte communities at -0.0011 Ton km2 hr-1, Intertidal respiration at -0.0113 Ton km2 hr-1 and Supratidal respiration at 0.0003 Ton km2 hr-1. As this challenge is a fundamental study that calculates the quantitative net carbon storage based on the blue carbon-based marine ecosystem, contributing to firstly, measuring the carbon respiration of cordgrass communities, reed communities, and non-vegetated tidal flats, which are potential blue carbon candidates in the study area, to establish representative values for carbon respiration, secondly, verifying the reliability of cover classification of native halophytes extracted through image classification technology, and thirdly, challenging to create a thematic map of carbon respiration, calculating the area and carbon respiration for each classification category.

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.

A Method to Separate Respiration and Pulse Signals from BCG Sensing Data for Companion Animals

  • Kwak, Ho-Young;Chang, Jin-Wook;Kim, Soo Kyun;Song, Woo Jin;Yun, Young-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.2
    • /
    • pp.163-170
    • /
    • 2022
  • Currently, as the number of families living with companion animals increases, the demand for information about the health status of companion animals has increased. As the demand for this increases, there is a need for a method to measure respiration and pulse in companion animals. Considering the characteristics of hairy companion animals, we want to measure respiration and pulse signals using BCG, which is different from adsorption ECG. Since this BCG method is made by mixing respiration and pulse signals into one signal, it is necessary to separate the respiration signal waveform and the pulse signal waveform from one signal waveform. In this paper, a wearable device for BCG measurement was implemented to measure the signal, and a method of separating the signal input from the BCG wearable device into a respiration signal and a pulse signal was proposed.

Sleep Management Pillow System (수면 관리 베개 시스템)

  • Ahn, Dohyun;Tran, Minh;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.212-217
    • /
    • 2019
  • In this paper, a sleep management pillow system for snoring detection and respiration measurement is investigated. The sleep management pillow system consists of four force sensing resistor(FSR) sensors, two microphones(MIC), a pillow, a measurement system. Four FSR sensors attached at the bottom part of the pillow are used for respiration measurement and snoring detection. Two microphones located at the middle left and right of the pillow are utilized for only snoring detection. The respiration and the snoring of ten young people were measured using the sleep management pillow system composed of a data acquisition board, interface circuit, and personal computer. The measurement accuracy of the respiration was about 98% and the measurement accuracy of the snoring was about 97%. The experiment results show that the sleep management pillow system can be used for snoring detection and respiration rate measurement during sleeping.