Browse > Article
http://dx.doi.org/10.9708/jksci.2022.27.02.163

A Method to Separate Respiration and Pulse Signals from BCG Sensing Data for Companion Animals  

Kwak, Ho-Young (Dept. of Computer Engineering, Jeju National University)
Chang, Jin-Wook (HRG Incorporated.)
Kim, Soo Kyun (Dept. of Computer Engineering, Jeju National University)
Song, Woo Jin (Dept. of Veterinary Medicine, Jeju National University)
Yun, Young-Min (Dept. of Veterinary Medicine, Jeju National University)
Abstract
Currently, as the number of families living with companion animals increases, the demand for information about the health status of companion animals has increased. As the demand for this increases, there is a need for a method to measure respiration and pulse in companion animals. Considering the characteristics of hairy companion animals, we want to measure respiration and pulse signals using BCG, which is different from adsorption ECG. Since this BCG method is made by mixing respiration and pulse signals into one signal, it is necessary to separate the respiration signal waveform and the pulse signal waveform from one signal waveform. In this paper, a wearable device for BCG measurement was implemented to measure the signal, and a method of separating the signal input from the BCG wearable device into a respiration signal and a pulse signal was proposed.
Keywords
BCG(ballistocardiogram); ECG(electrocardiogram); respiration; puls; signal separation;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 W. D. Cho, S. T. Choi, "Method and device for calculating heart rate using frequency analysis", Korean Patent, 10-2016-0053718, 2016.
2 Butterworth, S. "On the Theory of Filter Amplifiers", Experimental Wireless and the Wireless Engineer. 7:536-541, 1930.
3 Y.H. Noh, D.W. Jung, "Implementation and evaluation of the BCG measurement system for non-constrained health monitoring", JSST, Vol.19, No.1, pp.8-16, 2010. DOI:10.5369/JSST.2010.19.1.008   DOI
4 Y.G. Lim, "Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG", JISPS, Vol.19, No.3, pp.104-109, 2018. DOI:10.23087/jkicsp.2018.19.3. 003   DOI
5 Maxim integrated, "Max30102 High-Sensitive Pulse Oximeter and Heart-Rate Sensor for Wearable Health", https://www.maximintegrated.com, Oct. 2018.
6 https://en.wikipedia.org/wiki/Inflection_point
7 Y. G. Lim, K. K. Kim, and K. S. Park, "ECG measurement on a chair without conductive contact," IEEE Trans. Biomedical Engineering, vol. 53, no. 5, pp. 956-959, 2006. DOI:10.1109/TBME.2006.872823   DOI
8 B. Gribbin, A. Steptoe, and P. Sleight, "Pulse Wave Velocity as a Measure of Blood Pressure Change", Psychophysiology, Vol. 13, No.1, pp. 86-90, 1976. DOI:10.1111/j.1469-8986.1976.tb03344.x   DOI
9 Y. H. Noh, D. U. Jeonge, "Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System", Journal of Sensor Science and Technology, Vol.20, No.2, pp.118-123, 2011. DOI:10.5369/JSST.2011.20.2.118   DOI
10 S. K. Choi, G. L. Lee, "Heart rate monitoring and predictability of diabetes using ballistocardiogram(pilot study)", J. Digital Convergence, Vol.18, No.8, pp.231-242, 2020. https://doi.org/10.14400/ JDC.2020.18.8.231   DOI
11 https://en.wikipedia.org/wiki/Wavelet_transform
12 James W. Nilsson, Susan A. Riedel, "Electric Circuits (9th Edition)", Prentice Hall, 520p, 2011, ISBN 0136114997.
13 https://en.wikipedia.org/wiki/Ballistocardiography