• Title/Summary/Keyword: Respiration, Artificial

Search Result 76, Processing Time 0.033 seconds

Characteristics of accumulated soil carbon and soil respiration in temperate deciduous forest and alpine pastureland

  • Jeong, Seok-Hee;Eom, Ji-Young;Park, Ju-Yeon;Lee, Jae-Ho;Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • v.42 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • Background: For various reasons such as agricultural and economical purposes, land-use changes are rapidly increasing not only in Korea but also in the world, leading to shifts in the characteristics of local carbon cycle. Therefore, in order to understand the large-scale ecosystem carbon cycle, it is necessary first to understand vegetation on this local scale. As a result, it is essential to comprehend change of the carbon balance attributed by the land-use changes. In this study, we attempt to understand accumulated soil carbon (ASC) and soil respiration (Rs) related to carbon cycle in two ecosystems, artificially turned forest into pastureland from forest and a native deciduous temperate forest, resulted from different land-use in the same area. Results: Rs were shown typical seasonal changes in the alpine pastureland (AP) and temperate deciduous forest (TDF). The annual average Rs was $160.5mg\;CO_2\;m^{-2}h^{-1}$ in the AP, but it was $405.1mg\;CO_2\;m^{-2}h^{-1}$ in the TDF, indicating that the Rs in the AP was lower about 54% than that in the TDF. Also, ASC in the AP was $124.49Mg\;C\;ha^{-1}$ from litter layer to 30-cm soil depth. The ASC was about $88.9Mg\;C\;ha^{-1}$, and it was 71.5% of that of the AP. The temperature factors in the AP was high about $4^{\circ}C$ on average compared to the TDF. In AP, it was observed high amount of sunlight entering near the soil surface which is related to high soil temperature is due to low canopy structure. This tendency is due to the smaller emission of organic carbon that is accumulated in the soil, which means a higher ASC in the AP compared to the TDF. Conclusions: The artificial transformation of natural ecosystems into different ecosystems is proceeding widely in the world as well as Korea. The change in land-use type is caused to make the different characteristics of carbon cycle and storage in same region. For evaluating and predicting the carbon cycle in the vegetation modified by the human activity, it is necessary to understand the carbon cycle and storage characteristics of natural ecosystems and converted ecosystems. In this study, we studied the characteristics of ecosystem carbon cycle using different forms in the same region. The land-use changes from a TDF to AP leads to changes in dominant vegetation. Removal of canopy increased light and temperature conditions and slightly decreased SMC during the growing season. Also, land-use change led to an increase of ASC and decrease of Rs in AP. In terms of ecosystem carbon sequestration, AP showed a greater amount of carbon stored in the soil due to sustained supply of above-ground liters and lower degradation rate (soil respiration) than TDF in the high mountains. This shows that TDF and AP do not have much difference in terms of storage and circulation of carbon because the amount of carbon in the forest biomass is stored in the soil in the AP.

Survival Prediction of Rats with Hemorrhagic Shocks Using Support Vector Machine (지원벡터기계를 이용한 출혈을 일으킨 흰쥐에서의 생존 예측)

  • Jang, K.H.;Choi, J.L.;Yoo, T.K.;Kwon, M.K.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Hemorrhagic shock is a common cause of death in emergency rooms. Early diagnosis of hemorrhagic shock makes it possible for physicians to treat patients successfully. Therefore, the purpose of this study was to select an optimal survival prediction model using physiological parameters for the two analyzed periods: two and five minutes before and after the bleeding end. We obtained heart rates, mean arterial pressures, respiration rates and temperatures from 45 rats. These physiological parameters were used for the training and testing data sets of survival prediction models using an artificial neural network (ANN) and support vector machine (SVM). We applied a 5-fold cross validation method to avoid over-fitting and to select the optimal survival prediction model. In conclusion, SVM model showed slightly better accuracy than ANN model for survival prediction during the entire analysis period.

Sedation in the Critically Ill Patients (중환자에서의 진정 진통 치료)

  • Kim, Tae-Hyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • Optimal level of sedation and analgesia is important for the comfort and safety of critically ill patients. However, suboptimal sedation is relatively common in the intensive care unit (ICU) and it could cause prolonged mechanical ventilation and ICU stay, also increase delirium and ICU acquired weakness and resultant decreased survival. Therefore, accurate assessment of the level of sedation and analgesia, maintaining adequate level of sedation, and daily evaluation of each patient and following adjustment could be important treatment strategy in critically ill patients. Recently, the strategy for sedation in the ICU is changing toward the direction of lowering sedation level or even "no sedation" with concurrent use of analgesics and the use of ultra short acting analgesics could be helpful in some patients. Clinicians should be aware of the importance of algorithmic approach including daily interruption of sedative and assessment of sedation level and especially in the patients under mechanical ventilation, organizational approaches such as the 'ABCDE' bundle could improve the management of critically ill patients.

The Aneurysmal Subarachnoid Hemorrhage following Stellate Ganglion Block -A case report- (성상신경절 차단후 발생한 동맥류성 지주막하출혈 -증례 보고-)

  • Choi, In-Joo;Chang, Won-Young;Yoon, So-Young;Kim, Kyung-Bae
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.121-123
    • /
    • 1997
  • Stellate ganglion block(SGB) is frequently performed to relieve a patient from headache of various. We experienced a rare case of subarachnoid hemorrhage by aneurysmal rupture after SGB. A 46-year-old female patient diagnosed with tension headache, and normal MRI finding consulted our pain clinic. We performed right SGB in combination with greater occipital nerve block. The next day, we performed left SGB with 6 ml of 0.25% bupivacaine. She had no evidence of subarachnoid block or intravascular injection. 15 minutes after injection, she abruptly developed convulsion and loss of consciousness. She was given artificial respiration with oxygen. The diagnosis of ruptured left posterior communicating aneurysm was confirmed by 4-vessels angiography.

  • PDF

Bacterial Abundances and Enzymatic Activities under Artificial Vegetation Island in Lake Paldang (팔당호에 설치된 인공식물섬에서의 세균 수와 체외효소 활성도의 변화)

  • Byeon, Myeong-Seop;Yoo, Jae-Jun;Kim, Ok-Sun;Choi, Seung-Ik;Ahn, Tae-Seok
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.4 s.100
    • /
    • pp.266-272
    • /
    • 2002
  • For analyzing function of a microbial ecosystem which was created under the artificial vegetation island (AVI) installed at Lake Paldang, zooplankton and bacterial numbers and exoenzyme activities (${\beta}$-glucosidase and phosphatase) were measured biweekly from 3 November 2()()1 to 20 April 2002 at AVI site and control site. Under the AVI, the water quality was worse than control site in term of comparing the environmental parameters. But, zooplankton number of AVI site was 25 times higher than that of control site. Respiratory active bacterial numbers were 3-8 times higher at AVI site. In addition, enzymatic activities were higher at AVI site than those of control site. These results suggest that the zooplankton-phytoplankton-bacteria relationships are closely coupled with each other and organic materials are eliminated by respiration of zooplankton and bacterial activities.

Changes of [A-a] gas Gradient in Rabbits with Oxygen Toxicity (산소중독시 가토의 [A-a] gas Gradient 의 변화)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 1987
  • Respiratory care with oxygen inhalation is often a necessity to maintain life, and it is one of the important therapeutic adjuncts in respiratory disease and in intensive care after surgery. However, it has been reported that oxygen toxicity occurs after prolonged exposure to 100% 0, [Smith, 1899; Kistler et al. 1967; Schaffner et al. 1967; Rowland and Newman, 1969. Subjective symptoms of oxygen toxicity include tracheal irritation, frequent cough, some burning sensation in the trachea, tachypnea, severe dyspnea, etc. [Welch, 1963; Fisher et al, 1968; Milier et al, 1970; Clark and Lambertsen, 1971; Sackner, 1975]. Pathologic findings are atelectasis, injuries to the pulmonary capillaries and hemorrhage in the alveoli in gross specimens. There can be inflammation, proliferation of fibrin, thickening of alveolar membranes, degeneration of collagen fibers and interstitial edema in the microscopic findings. [Penrod, 1956; Cedergren, 1959; Bean, 1965; Schaffner, 1967]. Dubois and colleagues [1961] found that the amount of pulmonary surfactant was decreased in oxygen toxicity and atelectasis followed by the decreased pulmonary surfactant. Many authors reported that vital capacity, inspiratory force, pulmonary compliance, pulmonary capillary blood flow and pulmonary elasticity were deceased and arteriovenous shunting increased. [Comroe et al, 1945; Fuson et al, 1965; Kistler et al, 1966; Knowles and Blenner-hassett, 1967; Barber et al, 1978]. Many human volunteers were examined after prolonged exposure in a high oxygenated chamber and there were a few reports on animals with oxygen toxicity, subjects including rabbits. Gas partial pressures of alveoli and arteries were measured in rabbits exposed to 100% $O_2$ and the alveolar-arterial gas gradients were analyzed, which is the basis for the study of oxygen toxicity. These rabbits were divided into two groups; rabbits under natural respiration, and second group under artificial respiration with a respirator. The alveolar $PO_2$ [$P]AO_2$] and $PCO_2$ [$PACO_2$], and the arterial $PO_2$ [$PaO_2$] were measured under varying $O_2$ pressures; 15% $O_2$, 21% $O_2$ and 100% $O_2$.

  • PDF

Thermoregulatory Responses of Swamp Buffaloes and Friesian Cows to Diurnal Changes in Temperature

  • Koga, A.;Kurata, K.;Furukawa, R.;Nakajima, M.;Kanai, Y.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.8
    • /
    • pp.1273-1276
    • /
    • 1999
  • Several reports have indicated that a rectal temperature of buffaloes is easily influenced by their surroundings. To clarify an effect of changing environmental temperature on thermoregulatory responses of buffaloes, an environment with diurnal temperature changes of $25^{\circ}C$ to $35^{\circ}C$ was created using an artificial climate laboratory. Three swamp buffaloes and three Friesian cows were exposed to three different experimental periods as follows: Period 1 (constant temperature of $30^{\circ}C$, Period 2 (diurnally changing temperature) and Period 3 (diurnally changing temperature and fasting). Heat production, rectal temperature, respiration rate, heart rate and respiration volume were measured during each period. Rectal temperature of the buffaloes fluctuated diurnally with the changing temperature (Periods 2 and 3), but remained constant in cows. Mean heat production was significantly lower in buffaloes than in cows in Period 2 and 3. However, the maximum rectal temperature and the increment of heat production were not always lower in buffaloes than in cows during Period 2. These results show that a rectal temperature and heat production in buffaloes are markedly influenced by the diurnal changes in temperature. Compared with Bos Taurus cows, the differences may be attributed to the physiological features of buffaloes including a high heat conductivity of their bodies and an lower heat production.

Air flow transducer with turbulence chamber (와류 챔버를 사용하는 호흡기류 센서)

  • Lee, In-Kwang;Choi, Sung-Su;Kim, Goon-Jin;Jang, Jong-Chan;Kim, Sung-Sik;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1971-1972
    • /
    • 2008
  • Cardiopulmonary resuscitation(CPR) is an important clinical technique performing artificial ventilation and chest compression on a patient under emergent situation before arriving in hospital. Since the quality of CPR significantly affects the survival rate, it would be of great advantage to monitor respiration in real time during CPR. However, currently applied respiratory air flow transducers are difficult to apply with sensing elements in the middle of the flow axis. The present study developed a new turbulent air flow transducer conveniently applicable to CPR. Abrupt changes in diameter of the flow tube generated turbulence in air flow, thereby pressure difference was obtained to estimate the air flow rate, with no physical object on the flow plane. Expiration and inspiration were separated by the direction of the pressure difference, resulting in good symmetry. Pressure-flow relationship was tested on a quadratic model, which provided accurate enough estimation results. Therefore, the present turbulent air flow transducer seemed appropriate to monitor respiration during CPR.

  • PDF

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.