• 제목/요약/키워드: Respirable suspended particles (RSP)

검색결과 5건 처리시간 0.018초

도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 - (Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles -)

  • 백성옥;박상곤
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정 (Simultaneous NO2 and RSP Measurements Using Filtration Method)

  • 양원호;임성국;김문현
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화 (Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room)

  • 황건중;이문수;나도영
    • 한국연초학회지
    • /
    • 제20권1호
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Characterization of Respirable Suspended Particles and Polycyclic Aromatic Hydrocarbons associated with Environmental Tobacco Smoke

  • Baek, Sung-Ok;Park, Jin-Soo;Kim, Mi-Hyun;Roger A, Jenkins
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E호
    • /
    • pp.1-17
    • /
    • 2000
  • In this study, the concentrations of particulate organic constituents of environmental tobacco smoke(ETS) were determined using an environmental smog chamber, where ETS is the sole source of target compounds. ETS was generated in a 30 ㎥ environmental chamber by a number of different cigarettes, including the Kentucky 1R4F reference cigarette and eight commercial brands. A total of 12 experimental runs was conducted, and target analytes included a group of ETS markers both in vapor and particulate phase and a class of polycylic aromatic hydrocarbos(PAHs) associated with ETS particles. The mass concentrations of PAH in ETS particles were also determined. The average contents of benzo(a) pyrene and benzo(a) anthracene in ETS particles for the commercial brands were 12.8 and 21.5$\mu\textrm{g}$/g, respectively, There values are all somewhat higher than those determined previously by other studies. Results form the chamber study are further used to estimate the average and variability of cigarette yields for target compounds associated with ETS. Finally, ratios of RSP to the surrogate standards of UVPM, FPM and solanesol were calculated for each sample. The average conversion factors factors for the eight commercial brands were 7.3, 38, and 41 for UVPM, EPM, and solanesol, respectively. The UVPM and FPM factors are in good agreement with the recently published values. Whereas there might be a substantial difference in the solanesol content among cigarettes produced in different countries, the variability is somewhat greater than those of UVPM and FPM, Unfortunately, comparison of the PAH yield data from this study with literature values was complicated by a lack of consistency in cigarette smoke generating methodology. Validation of the PAH yields was also difficult due to a lack of information on the ETS related PAH in the literature. From and engineering viewpoint , however, these data on the cigarette yields of ETS components may still provide useful information to studies on the mathematical modeling of indoor air quality management regarding tobacco smoke as a source of interest, or to studies on the assessment of human exposure to ETS.

  • PDF

도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로- (Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants -)

  • 백성옥;김윤신
    • 한국대기환경학회지
    • /
    • 제14권4호
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF