THE EFFECT OF THE RECIPIENT SITE DEPTH AND DIAMETER ON THE IMPLANT PRIMARY STABILITY IN PIG'S RIBS (돼지 늑골에서 임플란트 수용부 깊이와 직경이 임플란트 일차 안정성에 미치는 효과)

  • Lim, Jin-Su;Kim, Hyun-Syeob;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.301-308
    • /
    • 2007
  • Purpose: This study was performed to compare and evaluate the effect of recipient site depths and diameters of the drills on the primary stability of implant in pig's ribs. Materials and methods: An intact pig's rib larger than 8 mm in width and 20 mm in height; RBM(resorbable blasting media) surface blasted ${\phi}3.75mm$ and 8.0 mm long USII Osstem Implants (Osstem Co., Korea) were used. To measure the primary stability, $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used. They were divided into 6 groups according to its recipient site formation method: D3H3, D3H5, D3H7, D3.3H3, D3.3H5, D3.3H7. Each group had, as indicated, 10 implants placed, and total 60 implants were used. The mean value was obtained by 4-time measurements each on mesial, distal, buccal, and lingual side perpendicular to the long axis of the implant using $Periotest^{(R)}$ and $Osstell^{TM}$. For statistical analysis one-way ANOVA was used to compare the mean value of each group, and the correlation between placement depths and the primary stability, and that of measuring instruments was analyzed using SPSS 12.0. Results: The primary stability of the implants increased as the placement depths increased (p<0.05), and showed a proportional relationship (p<0.01). The primary stability increased when the diameter of the recipient site was smaller than that of the implant but with no statistical significance. There was a strong correlation between $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.01). Conclusion: These results suggest that increasing the placement depth of implants enhances the primary stability of implant.

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs (성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구)

  • Sun, Ki-Jong;Park, Jae-Young;Jung, Eun-Gyeong;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.209-221
    • /
    • 2007
  • Recently, immediately after losing teeth. implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materals, $STAGE-1^{(R)}$($4.1{\times}8mm$, Lifecore, USA), $SS-III^{(R)}$($4.0{\times}8mm$, OSSTEM, Korea) and $IFI^{(R)}$($4.0{\times}8mm$, Dio, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed $-2\;{\sim}\;-5$ and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among group(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%. respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.

PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION (사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성)

  • Sim, Jung-Woo;Cho, Jin-Yong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.