• 제목/요약/키워드: Resonant Inverter

Search Result 601, Processing Time 0.025 seconds

A CW $CO_2$ Laser Using a High Voltage Dc-dc Converter with Half-bridge Resonant Inverter and Cockroft-Walton Multiplier

  • Chung, Hyun-Ju;Joung, Jong-Han;Kim, Geun-Young;Min, Byoung-Dae;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.123-129
    • /
    • 2003
  • We propose a high voltage dc-dc converter for a CW (continuous wave) $CO_2$ laser system using a current resonant half-bridge inverter and a Cockcroft-Walton circuit. This high voltage power supply includes a 2-stage voltage multiplier driven by a regulated half-bridge series resonant inverter. The inverter drives a step-up transformer and the secondary transformer is applied to the voltage multiplier. It is highly efficient because of the reduced amount of switching losses by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up secondary transformer combined with the Cockroft-Walton circuit. We obtained a maximum laser output power of 44 W and a maximum system efficiency of over 16%.

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

Resonant-type Electronic Ballast for HID Lamp (HID 램프용 공진형 전자식 안정기)

  • Lee, Seong-Hui;Lee, Chi-Hwan;Gwon, U-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.530-535
    • /
    • 2001
  • Resonant-type electronic ballast for a metal halide discharge(MHD) lamp is proposed and implemented for 400W MHD lamp. HID lamps have good color rendition, long life and good focusing capability but they have flickers by acoustic resonance when driven at high frequency. A new control method is employed to remove acoustic resonance related instability in HID lamp. By using the amplitude modulation, a spread spectrum effect is employed on the ballast. The control loop of resonant inverter is analyzed and a current is designed. The ballast consists of a power factor controller, an half-bridge resonant inverter, a simple ignitor and an integrator with OP-amps. The experimental results show the good performance as PF 0.93, ballast loss 22W at output 400W and the conducted EMI level is below 60dBuV.

  • PDF

Characteristic analysis of the resonant current injection type high frequency resonant inverter using ZVS (ZVS를 이용한 공진전류 주입형 고주파 공진 인버터의 특성해석)

  • Won, Jae-Sun;Kim, Hae-Jun;Cho, Gyu-Pan;Kim, Dong-Hee;Bae, Young-Ho;Min, Byung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1038-1040
    • /
    • 2001
  • A half-bridge type resonant current injection type high frequency resonant inverter using ZVS(Zero-Voltage-Switching) used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency and load resistance. According to the calculated characteristics value, this paper proves the validity of theoretical analysis through the Pspice.

  • PDF

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

A Dimmable High Frequency Resonant Inverter for Electrodeless Lamps (조광제어형 무전극 램프용 고주파 공전형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.487-489
    • /
    • 2004
  • As the electrodes are not needed, the electrodeless lamps using the induction discharge have a long lifetime and are robust against the variable output condition of a ballast. This paper proposed a dimmable resonant inverter for the electrodeless lamps. The proposed resonant inverter formed a half bridge inverter adopted FWM to control the average output power of the inverter and the illumination of a lamp. In this paper, the proposed dimming algorithm was described and the prototype experimental setup for 100W electrodeless lamps was carried out to verify the validity of the proposed dimming method.

  • PDF

Auxiliary Resonant Commutated Leg Snubber Linked 3-Level 3-Phase Voltage Source Soft-Switching Inverter

  • Yamamoto, Masayoshi;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • This paper presents a performance analysis in steady-state of a novel type Auxiliary Resonant Commutation Snubber-linked 3-level 3-phase voltage source soft switching inverter suitable and acceptable for high-power applications in comparison with other three types of 3-level 3-phase voltage source soft switching inverters. This soft switching inverter operation which can operate under a condition of Zero Voltage Switching (ZVS). The practical steady -state performances of this inverter are illustrated and evaluated on the basis of the experimental results.

Characteristics analysis of time sharing type high frequencyinverter using serial-parallel resonant (직.병렬공진을 이용한 시분할형고주파 인버터의 특성해석)

  • 조규판;이경호;노채균;배영호;심광렬
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.173-178
    • /
    • 2000
  • The time sharing type high frequency inverter using serial-parallel resonant to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, according to the calculated characteristics value, a method of the circuit design and operating characteristics of the inverter is proposed. In addition, this paper proves the validity of theoretical analysis through Simulation. This proposed inverter show that it can be practically used in future as power source system for induction heating application, DC-DC converter etc.

  • PDF

ZCS-PFM Series Resonant High Frequency Inverter for Electromagnetic Induction Eddy Current-Heated Roller

  • Mun, Sang-Pil;Jung, Sang-Hwa;Kim, Chang-Il;Kim, Sang-Don;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.419-422
    • /
    • 2008
  • This paper presents a novel prototype of ZCS-PFM high frequency series resonant Inverter using IGBT power module for electromagnetic induction eddy current-heated roller in copy and printing machines. The operating principle and unique features of this voltage source half bridge inverter with two additional soft commutation inductor snubber are presented Including the transformer modeling of induction heated rolling drum. This soft switching inverter can achieve stable zero current soft commutation under a discontinuous and continuous resonant load current for a widely specified power regulation processing. The experimental results and computer-aided analysis of this inverter are discussed from a practical point of view.

  • PDF