• 제목/요약/키워드: Resonance sensitivity

검색결과 464건 처리시간 0.022초

주파수 영역 민감도 방법을 이용한 집중 질량 구조물의 응답 해석 (Analysis of Response of Lumped Mass System Using Sensitivity Method in Frequency Domain)

  • 백문열;기창두
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.164-169
    • /
    • 1997
  • The aim of this paper is to present some results of sensitivity analysis in frequency domain. The sensitivity fonctions in frequency domain is not depend on the external excitation but depend on the frequency of the system's resonance. The sensitivity functions are determined as function of partial derivatives of system transfer functions taken with respect to system design parameters. The logarithmic sensitivity function is the dimensionless sensitivity funciton available, making it useful to compare the influence of various parameters on system variables. Two degree of fredom system is used to illustrate the procedure for sensitivity analysis proposed in this paper.

  • PDF

Sensitivity simulation on isotopic fissile measurement using neutron resonances

  • Lee, YongDeok;Ahn, Seong-Kyu;Choi, Woo-Seok
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.637-643
    • /
    • 2022
  • Uranium and plutonium are required to be accounted in spent fuel head-end and major recovery area in pyro-process for safeguards purpose. The possibility of neutron resonance technique, as a nondestructive analysis, was simulated on isotopic fissile analysis for large scale process. Neutron resonance technique has advantage to distinguish uranium from plutonium directly in mixture. Simulation was performed on U235 and Pu239 assay in spent fuel and for scoping examination of assembly type. The resonance energies were determined for U235 and Pu239. The linearity in the neutron transmission was examined for the selected resonance energies. In addition, the limit for detection was examined by changing sample density, thickness and content for actual application. Several factors were proposed for neutron production and the moderated neutron source was simulated for effective and efficient transmission measurement. From the simulation results, neutron resonance technique is promising to analyze U235 and Pu239 for spent fuel assembly. An accurate fissile assay will contribute to an increased safeguards for the pyro-processing system and international credibility on the reuse of fissile materials in the fuel cycle.

Enhancement of Antibacterial Activity of Short Tryptophan-rich Antimicrobial Peptide Pac-525 by Replacing Trp with His(chx)

  • Ahn, Mija;Rajasekaran, Ganesan;Gunasekaran, P.;Ryu, Eun Kyoung;Lee, Ga-Hyang;Hyun, Jae-Kyung;Cheong, Chaejoon;Kim, Nam-Hyung;Shin, Song Yub;Bang, Jeong-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2818-2824
    • /
    • 2014
  • Trp residue is considered as one of the important constituents in antimicrobial peptides (AMPs) as it presence secured good activities in many cases. However, it is preferable to be changed because of their sensitivity towards light. We have synthesized the short Trp-rich AMP Pac-525 and its analogues to investigate the possibility of His(chx) as possible replacement analogue for Trp in AMPs. Based on the assay result of the antibacterial activity including anti-MRSA activity, His(chx) is considered as good candidate for the Trp replacement. Through these study, we found that His(chx) had several merits to design therapeutic antimicrobial agents compare to Trp in terms of i) increasing antibacterial activity without hemolytic activity, ii) successful in designing the short peptide (only four residues), iii) having anti-MRSA activity, iv) overcoming the light sensitivity. Furthermore, transmission electron microscopy (TEM) and dye leakage experiments suggested that P11 and P16 containing His(chx) kill bacteria via forming pore/ion channels on bacterial cell membranes.

광-유체링공진기(OFRR) 바이오센서에 관한 공진이동과 양호도의 시뮬레이션 (Simulation of Resonance Shift and Quality Factor for Opto-fluidic Ring Resonator (OFRR) Biosensors)

  • 조한근;한진우;양길모
    • Journal of Biosystems Engineering
    • /
    • 제36권1호
    • /
    • pp.23-32
    • /
    • 2011
  • In this work, the finite element method was used to investigate the shifts of resonance frequencies and quality factor of whispering-gallery-mode (WGM) for an opto-fluidic ring resonator (OFRR) biosensor. To describe the near-field radiation transfer, the time-domain Maxwell's equations were employed and solved by using the in-plane TE wave application mode of the COMSOL Multiphysics with RF module. The OFRR biosensor model under current study includes a glass capillary with a diameter of 100 mm and wall thickness of 3.0 mm. The resonance energy spectrum curves in the wavelength range from 1545 nm to 1560 nm were examined under different biosensing conditions. We mainly studied the sensitivity of resonance shifts affected by changes in the effective thickness of the sensor resonator ring with a 3.0 mm thick wall, as well as changes in the refractive index (RI) of the medium inside ring resonators with both 2.5 mm and 3.0 mm thick walls. In the bulk RI detection, a sensitivity of 23.1 nm/refractive index units (RIU) is achieved for a 2.5 mm thick ring. In small molecule detection, a sensitivity of 26.4 pm/nm is achieved with a maximum Q-factor of $6.3{\times}10^3$. These results compare favorably with those obtained by other researchers.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

Combination of Magnetic Resonance Spectroscopy and 11C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma

  • Nijiati Kudulaiti;Tianming Qiu;Junfeng Lu;Huiwei Zhang;Zhengwei Zhang;Yihui Guan;Dongxiao Zhuang;Jinsong Wu
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.967-975
    • /
    • 2019
  • Objective: To evaluate whether the combination of magnetic resonance spectroscopy (MRS) and 11C-methionine positron emission tomography (11C-MET PET) could increase accurate diagnostic sensitivity for non-enhancing supratentorial gliomas. Materials and Methods: Between February 2012 and December 2017, 109 patients with non-enhanced supratentorial lesions on contrast-enhanced MRI were enrolled. Each patient underwent MRS and 11C-MET PET before treatment. A lesion was considered to be a glioma when either the MRS or 11C-MET PET results reached the diagnostic threshold. The radiological diagnosis was compared with the pathological diagnosis or medical diagnostic criteria. Results: The sensitivity and specificity were 60.0% and 50.0% for MRS and 75.8% and 50.0% for 11C-MET PET, respectively. Upon combining the two modalities, the sensitivity and specificity of the imaging-based diagnosis prior to surgery reached 89.5% and 42.9%, respectively. Statistically significant differences in the sensitivities were observed between the combined and individual approaches (MRS alone, 89.5% vs. 60.0%, p < 0.001; 11C-MET PET alone, 89.5% vs. 75.8%, p = 0.001). However, no significant differences in specificity were observed between the combined and individual modalities. Conclusion: The combination of MRS and 11C-MET PET findings significantly increases accurate diagnostic sensitivity for non-enhancing supratentorial gliomas without significantly lowering the specificity. This finding suggests the potential of the combined MRS and 11C-MET PET approach in clinical applications.

Comparison between Computer Tomography and Magnetic Resonance Imaging in the Diagnosis of Small Hepatocellular Carcinoma

  • Lertpipopmetha, Korn;Tubtawee, Teeravut;Piratvisuth, Teerha;Chamroonkul, Naichaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권11호
    • /
    • pp.4805-4811
    • /
    • 2016
  • Background: Hepatocellular carcinomas (HCCs) less than 2 cm in diameter generally demonstrate a good outcome after curative therapy. However, the diagnosis of small HCC can be problematic and requires one or more dynamic imaging modalities. This study aimed to compare the sensitivity and agreement between CT and MRI for the diagnosis of small HCCs. Methods: CT and/or MRI scans of HCCs (1-2 cm) diagnosed by histopathology or typical vascular pattern according to the 2005 AASLD criteria were blindly reviewed by an abdominal radiologist. The reports were defined as conclusive/typical when arterial enhancement and washout during the portal/delayed phases were observed and as inconclusive when typical vascular patterns were not observed. The sensitivity and Cohen's kappa (k) for agreement were calculated. Results: In 27 patients, 27 HCC nodules (1-2 cm) were included. Diagnosis with a single-imaging modality (CT or MRI) was 81 % versus 48 % (p = 0.01). The CT sensitivity was significantly higher than MRI (78 % versus 52 %, p = 0.04). Among 27 nodules that underwent both CT and MRI, a discordance in typical enhancement patterns was found (k = 0.319, p = 0.05). In cases with inconclusive CT results, MRI gave only an additional 3.7 % sensitivity to reach a diagnosis. In contrast, further CT imaging following inconclusive MRI results gave an additional 29.6 % sensitivity.Conclusions: A single typical imaging modality is sufficient to diagnose small HCCs. Compared with MRI, multiphasic CT has a higher sensitivity. The limitations of MRI could be explained by the greater need for patient cooperation and the types of MRI contrast agent.

산화아연을 이용한 나노격자 구조의 표면 플라즈몬 공명 (Surface Plasmon Resonance Based on ZnO Nano-grating Structure)

  • 김두근;김선훈;기현철;김회종;오금윤;최영완
    • 전기학회논문지
    • /
    • 제59권5호
    • /
    • pp.922-926
    • /
    • 2010
  • We have investigated the grating coupled surface plasmon resonance (GC-SPR) sensors using ZnO nano-grating structures to enhance the sensitivity of an SPR sensor. The GC-SPR sensors were analyzed using the finite-difference time-domain method. The optimum resonance angles of 49 degrees are obtained in the 150 nm wide grating structure with a period of 300 nm for the ZnO thickness of 30 nm. Then, the ZnO nano-grating patterns were fabricated by using laser interference lithography. The measured resonance angle of nano-grating patterns was around 49 degrees. Here, an enhanced evanescent field is obtained due to the surface plasmon on the edge of the bandgap when the ZnO grating structures are used to excite the surface palsmon.

원통형 수직 펌프의 공진회피를 위한 접수진동해석 (Fluid-Structure Interaction (FSI) Modal Analysis to Avoid Resonance of Cylinder Type Vertical Pump at Power Plant)

  • 이재환;왕즈텅;아코마링
    • 대한조선학회논문집
    • /
    • 제55권4호
    • /
    • pp.321-329
    • /
    • 2018
  • Resonance phenomena occurs at large vertical pump which is operating to cool down the hot steam using sea water in the power plant. To avoid the resonance, the natural frequency needs to be isolated about 20% from motor operating speed. Yet, excessive vibration occurs especially at low tide. At first, natural frequency of the whole pump system and each part is calculated using ANSYS. As it is revealed in the previous journal papers that only circular pipe part is related to resonance, the FSI technique is applied for free vibration analysis. The natural frequency is reduced to 60% (compared to that) of the frequency measured in air as it is similar to other published results. And the frequency obtained by finite element analysis is almost same to that obtained from modal test. Based on the accurate finite element model and analysis, design change is tried to avoid the resonance by changing the thickness of pipe and base supporting plate. In stead of doing optimization process, design sensitivity is computed and used to find such designs to avoid resonance.

감온 페라이트를 이용한 비접촉 온도측정시스템의 감도특성 (Sensitivity of non-contact Temperature Measurement Using Temperature Sensitive Ferrite)

  • 신광호;김영학
    • 한국자기학회지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2004
  • 비접촉 온도측정 시스템을 구현하기 위하여 감온페라이트를 이용하여 제작한 인던턴스소자와 캐피시터를 접속하여 LC공진형 센서를 구성하고, 비접촉 온도계측성능에 대하여 조사하였고, 송수신기 사이의 거리에 대한 측정감도에 대하여 검토하였다. 감온 페라이트가 가지는 투자율의 온도의존성에 의해서 제작한 센서의 인덕턴스와 공진주파수가 변화함을 알 수 있었고, 공진주파수의 변화를 비접촉으로 검출함으로써 비접촉으로 온도를 검출할 수 있음을 알 수 있었다. 또한 비접촉 측정 감도는 송 $.$수신기 사이 거리의 6승에 비례하는 감소하는 것을 알 수 있었다.