저온 증착된 불소도핑 주석 산화 박막의 광학적·전기적 특성 (Optical and Electrical Properties of Fluorine-Doped Tin Oxide Prepared by Chemical Vapor Deposition at Low Temperature)

  • 박지훈;전법주
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.517-524
    • /
    • 2013
  • The electrical and optical properties of fluorine-doped tin oxide films grown on polyethylene terephthalate film with a hardness of 3 using electron cyclotron resonance plasma with linear microwave of 2.45 GHz of high ionization energy were investigated. Fluorine-doped tin oxide films with a magnetic field of 875 Gauss and the highest resistance uniformity were obtained. In particular, the magnetic field could be controlled by varying the distribution in electron cyclotron deposition positions. The films were deposited at various gas flow rates of hydrogen and carrier gas of an organometallic source. The surface morphology, electrical resistivity, transmittance, and color in the visible range of the deposited film were examined using SEM, a four-point probe instrument, and a spectrophotometer. The electromagnetic field for electron cyclotron resonance condition was uniformly formed in at a position 16 cm from the center along the Z-axis. The plasma spatial distribution of magnetic current on the roll substrate surface in the film was considerably affected by the electron cyclotron systems. The relative resistance uniformity of electrical properties was obtained in film prepared with a magnetic field in the current range of 180~200A. SEM images showing the surface morphologies of a film deposited on PET with a width of 50 cm revealed that the grains were uniformly distributed with sizes in the range of 2~7 nm. In our experimental range, the electrical resistivity of film was able to observe from $1.0{\times}10^{-2}$ to $1.0{\times}10^{-1}{\Omega}cm$ where optical transmittance at 550 nm was 87~89 %. These properties were depended on the flow rate of the gas, hydrogen and carrier gas of the organometallic source, respectively.

Predicting the Frequency of Combustion Instability Using the Measured Reflection Coefficient through Acoustic Excitation

  • Bae, Jinhyun;Yoon, Jisu;Joo, Seongpil;Kim, Jeoungjin;Jeong, Chanyeong;Sohn, Chae Hoon;Borovik, Igor N.;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권4호
    • /
    • pp.797-806
    • /
    • 2017
  • In this study, the reflection coefficient (RC) and the flame transfer function (FTF) were measured by applying acoustic excitation to a duct-type model combustor and were used to predict the frequency of the combustion instability (CI). The RC is a value that varies with the excitation frequency and the geometry of the combustor as well as other factors. Therefore, in this study, an experimentally measured RC was used to improve the accuracy of prediction in the cases of 25% and 75% hydrogen in a mixture of hydrogen and methane as a fuel. When the measured RCs were used, an unstable condition was correctly predicted, which had not been predicted when the RCs had been assumed to be a certain value. The reason why the CI occurred at a specific frequency was also examined by comparing the peak of the FTF with the resonance frequency, which was calculated using Helmholtz's resonator analysis and a resonance frequency equation. As the CI occurred owing to the interaction between the perturbation in the rate of heat release and that in the pressure, the CI was frequent when the peak of the FTF was close to the resonance frequency such that constructive interference could occur.

Acute Disseminated Encephalomyelitis Presenting as Rhombencephalitis: An Atypical Case Presentation

  • Hwang, Joonseok;Lee, A Leum;Chang, Kee Hyun;Hong, Hyun Sook
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권3호
    • /
    • pp.186-190
    • /
    • 2015
  • Acute disseminated encephalomyelitis (ADEM) is a demyelinating and inflammatory condition of the central nervous system, occurring predominantly in white matter. ADEM involving the rhombencephalon without affecting the white matter is very rare. Here, we present an unusual case of ADEM involving only the rhombencephalon in a 4-year-old Asian girl. The patient complained of pain in the right lower extremities, general weakness, ataxia, and dysarthria. The initial brain CT showed subtle ill-defined low-density lesions in the pons and medulla. On brain MRI, T2 high signal intensity (T2-HSI) lesions with mild swelling were present in the pons, both middle cerebellar peduncles, and the anterior medulla. The initial diagnosis was viral encephalitis involving the rhombencephalon. Curiously, a cerebrospinal fluid (CSF) study revealed no cellularity, and negative viral marker findings. Three weeks later, follow up brain MRI showed that the extent of the T2-HSI lesions in the brain stem had decreased. After reinvestigation, it was found that she had a prior history of upper respiratory infection. In this case, we report the very rare case of a patient showing isolated involvement of the rhombencephalon in ADEM, mimicking viral rhombencephalitis on CT and MR imaging. ADEM can involve unusual sites such as the rhombencephalon in isolation, without involvement of the white matter or deep gray matter and, therefore, should be considered even when it appears in unusual anatomical areas. Thorough history taking is important for making a correct diagnosis.

PZT 캔틸레버의 길이와 면적에 따른 에너지 하베스팅 장치의 출력 특성 (Micro Power Properties of Harvesting Devices as a Function of PZT cantilever length and gross area)

  • 김인성;주현규;송재성;김민수;정순종;이대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1246-1247
    • /
    • 2008
  • With recent advanced in portable electric devices, wireless sensor, MEMS and bio-Mechanics device, the new typed power supply, not conventional battery but self-powered energy source is needed. Particularly, the system that harvests from their environments are interests for use in self powered devices. For very low powered devices, environmental energy may be enough to use power source. Therefore, in other to made piezoelectric energy harvesting device, PMN-PZT thick film was formed by the screen printing method on the Ag/Pd coated alumina substrate. The layer was 8 layers and slurry where a-terpineol, ethycellulose, ferro B-75001 as Vehicle, PMN-PZT powder used are fabricated by ball mill. The output power quality was be also investigated by changing the load resistance, weight and frequency. The made piezoelectric energy harvesting device was resulted from the conditions of 33$k{\Omega}$, 0.25g, 197Hz respectively. The thick film was prepared at the condition of 2.75Vrms, and its power was 230${\mu} W$ and its thickness was 56${mu}m$. The piezoelectric energy harvesting device output voltage was increased, when the load weight, load resistance was increasing and resonance frequency was diminishing. The other side, resonance frequency was diminished, when the weight was increasing. And output power was continuously it changed by load resistance, output voltage, weight and resonance frequency.

  • PDF

만성신부전증에 의한 이차성 부갑상선기능항진증 환자에서 양쪽 대퇴사두건 동시 파열: 증례 보고 (Simultaneous Bilateral Quadriceps Tendon Rupture in Patient with Secondary Hyperparathyroidism due to Chronic Renal Failure: A Case Report)

  • 심종준;심재찬;하정구;이경은;이기재;김호균;서정호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.169-172
    • /
    • 2012
  • 양측 대퇴사두건의 동시성 파열은 매우 드물며 몇 개의 증례만이 문헌에 보고되어 있다. 정확한 병인은 아직까지 알려지지 않았다. 그러나 만성신부전에 의한 이차성 부갑상선기능항진증과 같은 만성 대사성 질환을 앓고 있는 환자들에게 드물게 발생한다. 저자들은 만성신부전에 의한 이차성부갑상선기능항진증 환자에서 대퇴사두건이 양측 동시 파열된 1예를 경험하였기에 문헌고찰과 함께 보고하고자 한다.

pH Effect on the Structure of Reduced NifU-like Protein from Helicobacter pylori

  • Lee, Ki-Young;Kim, Ji-Hun;Bae, Ye-Ji;Lee, Bong-Jin
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.106-111
    • /
    • 2015
  • Helicobacter pylori (H. pylori) survives in acidic and fluctuating pH conditions of the stomach. The pH effect on H. pylori proteins is important for the advanced understanding of its evolution and viability, although this bacterium has the molecular machinery that neutralizes the acidic condition. HP1492 is known as a conserved NifU-like protein from H. pylori. NifU is a nitrogen fixation protein that mediates the transfer of iron-sulfur (Fe-S) cluster to iron-sulfur proteins like ferredoxin. Commonly, the monomeric reduced state of NifU can be converted to the dimeric oxidized state by intermolecular disulfide bond formation. Because it remains unclear that HP1492 actually behaves as known NifU protein, we first found that this protein can adopt both oxidized and reduced forms using size exclusion chromatography. Circular dichroism experiment showed that HP1492 is relatively well-structured at pH 6.5, compared to other pH conditions. On the basis of the backbone resonance assignment of HP1492, we further characterized the residues that are sensitive to pH using NMR spectroscopy. These residues showing large chemical shift changes could be mapped onto the secondary structure of the protein. Our results could provide the foundation for structural and biophysical studies on a wide spectrum of NifU proteins.

장 회전 이상과 함께 발생한 부유비장 경색의 자기공명영상에서의 소견: 증례 보고 (MR Images of Infarction of Wandering Spleen Associated with Intestinal Non-rotation)

  • 김유진;김미영;김여주;김윤정;김우철;서창해;최석진;조재성
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권3호
    • /
    • pp.253-257
    • /
    • 2014
  • 부유비장은 희귀한 임상질환으로서 느슨한 비장현수인대에 의해 발생하며 이는 비장혈관줄기의 비틀림을 유발한다. 복통이 있는 7세 여자 환아의 전산화 단층촬영에서 하복부에 조영증강되지 않는 종괴 소견이 있었고 소장은 우측 복부에 대장은 좌측 복부에 위치하였다. 자기공명영상 스캔에서 비틀린 비장혈관줄기와 함께 조영증강 되지 않는 불균질 신호강도의 종괴가 있었다. 지금까지 자기공명영상으로 진단된 부유비장의 증례 보고는 매우 드물게 보고되어 있다.

Membrane을 이용한 박막센서 특성 분석 (The Characteristic Analysis of Thin Film Sensor using The Membrane)

  • 이순우;김상훈;안진호
    • 마이크로전자및패키징학회지
    • /
    • 제9권3호
    • /
    • pp.37-41
    • /
    • 2002
  • 본 연구에서는 자기 공명 특성을 이용한 박막 센서의 멤브레인 및 박막 센서의 특성을 알아보았다. 멤브레인으로 유망한 물질로 $Si_xN_y$과 SiC가 있으며, 최적의 멤브레인 형성 조건을 알고자 박막의 잔류 응력 및 물성을 비교 분석하였다. 그 중에서 박막 센서에 적용 가능한 멤브레인으로 SiC보다 적절한 인장응력과 낮은 열팽창 계수를 가지는 $Si_xN_y$이 센서의 구조층으로 우수하였으며, $Si_xN_y$위에 박막 센서 물질을 증착 및 패턴닝(patterning)을 함으로써 센서의 자기 이력 곡선 및 자기 공진 주파수를 분석하였다. 센서에 인가되는 외부 자기장을 제거하면 자장에 의해 형성된 자화(magnetization)가 탄성 모드로 바뀌면서 에너지 방출에 의해 센서에서 전압이 발생하는데 이때 전압 발생 구간이 길어지면 기계적 진동이 야기되어 신호가 발생한다. 그리고 센서의 길이 및 폭이 증가할수록 자기공명 주파수가 감소하는 것을 볼 수 있다.

  • PDF

족부 족관절 골좌상에서 자기공명영상 분류에 따른 통증의 호전 (Improvement of Pain according to Magnetic Resonance Imaging Classification in Bone Contusion around Foot and Ankle)

  • 김형직;이광복
    • 대한족부족관절학회지
    • /
    • 제23권4호
    • /
    • pp.183-188
    • /
    • 2019
  • Purpose: Bone contusion is usually treated with conservative therapy for 3 months. Bone contusion around knee and hip joints has been extensively reported on, but there are scant reports on this condition in foot and ankle joints. This study evaluated the nature, characteristics and location of bone contusion around foot and ankle joints to enlighten clinicians on how to better treat this disease entity. Materials and Methods: We classified bone contusion of the 76 patients into three types (102 sites; 47 ankle sprains, 18 traffic accidents, 11 falls) according to the Costa-Paz system with employing magnetic resonance imaging (MRI), and the study then analyzed the common sites and areas of occurrence according to the mechanism of injury and duration of pain after first conducting conservative therapy. Results: Of the 76 patients (102 sites) on the MRI, 43 case (42.2%) for talus, 19 cases for distal tibia, and 12 cases for calcaneus were involved. The classification, according to the Costa-Paz system, was Type I, 51 cases; Type II, 32 cases; and Type III, 19 cases. The duration of pain after conservative treatment was 12.15±2.17 weeks for Type I, 14.5±2.15 weeks for Type II, and 21.0±3.8 weeks for Type III. Conclusion: The most common location of post-traumatic bone contusion around both the foot and ankle is the talus, distal tibia, and calcaneus. The most common type of injury noted on MRI is a diffuse signal with change of the medullary component (Type I), In cases of bone contusion extending to a subjacent articular surface or disruption or depression of the normal contour of the cortical surface (Types II, III), the patients' pain appears to last longer. Thus, it is necessary to consider a longer period of conservative treatment in cases of Types II and III bone contusion because the patients' pain may last longer than 3 months.

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.