• Title/Summary/Keyword: Resonance condition

Search Result 625, Processing Time 0.03 seconds

Optical and Electrical Properties of Fluorine-Doped Tin Oxide Prepared by Chemical Vapor Deposition at Low Temperature (저온 증착된 불소도핑 주석 산화 박막의 광학적·전기적 특성)

  • Park, Ji Hun;Jeon, Bup Ju
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.517-524
    • /
    • 2013
  • The electrical and optical properties of fluorine-doped tin oxide films grown on polyethylene terephthalate film with a hardness of 3 using electron cyclotron resonance plasma with linear microwave of 2.45 GHz of high ionization energy were investigated. Fluorine-doped tin oxide films with a magnetic field of 875 Gauss and the highest resistance uniformity were obtained. In particular, the magnetic field could be controlled by varying the distribution in electron cyclotron deposition positions. The films were deposited at various gas flow rates of hydrogen and carrier gas of an organometallic source. The surface morphology, electrical resistivity, transmittance, and color in the visible range of the deposited film were examined using SEM, a four-point probe instrument, and a spectrophotometer. The electromagnetic field for electron cyclotron resonance condition was uniformly formed in at a position 16 cm from the center along the Z-axis. The plasma spatial distribution of magnetic current on the roll substrate surface in the film was considerably affected by the electron cyclotron systems. The relative resistance uniformity of electrical properties was obtained in film prepared with a magnetic field in the current range of 180~200A. SEM images showing the surface morphologies of a film deposited on PET with a width of 50 cm revealed that the grains were uniformly distributed with sizes in the range of 2~7 nm. In our experimental range, the electrical resistivity of film was able to observe from $1.0{\times}10^{-2}$ to $1.0{\times}10^{-1}{\Omega}cm$ where optical transmittance at 550 nm was 87~89 %. These properties were depended on the flow rate of the gas, hydrogen and carrier gas of the organometallic source, respectively.

Predicting the Frequency of Combustion Instability Using the Measured Reflection Coefficient through Acoustic Excitation

  • Bae, Jinhyun;Yoon, Jisu;Joo, Seongpil;Kim, Jeoungjin;Jeong, Chanyeong;Sohn, Chae Hoon;Borovik, Igor N.;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.797-806
    • /
    • 2017
  • In this study, the reflection coefficient (RC) and the flame transfer function (FTF) were measured by applying acoustic excitation to a duct-type model combustor and were used to predict the frequency of the combustion instability (CI). The RC is a value that varies with the excitation frequency and the geometry of the combustor as well as other factors. Therefore, in this study, an experimentally measured RC was used to improve the accuracy of prediction in the cases of 25% and 75% hydrogen in a mixture of hydrogen and methane as a fuel. When the measured RCs were used, an unstable condition was correctly predicted, which had not been predicted when the RCs had been assumed to be a certain value. The reason why the CI occurred at a specific frequency was also examined by comparing the peak of the FTF with the resonance frequency, which was calculated using Helmholtz's resonator analysis and a resonance frequency equation. As the CI occurred owing to the interaction between the perturbation in the rate of heat release and that in the pressure, the CI was frequent when the peak of the FTF was close to the resonance frequency such that constructive interference could occur.

Acute Disseminated Encephalomyelitis Presenting as Rhombencephalitis: An Atypical Case Presentation

  • Hwang, Joonseok;Lee, A Leum;Chang, Kee Hyun;Hong, Hyun Sook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.186-190
    • /
    • 2015
  • Acute disseminated encephalomyelitis (ADEM) is a demyelinating and inflammatory condition of the central nervous system, occurring predominantly in white matter. ADEM involving the rhombencephalon without affecting the white matter is very rare. Here, we present an unusual case of ADEM involving only the rhombencephalon in a 4-year-old Asian girl. The patient complained of pain in the right lower extremities, general weakness, ataxia, and dysarthria. The initial brain CT showed subtle ill-defined low-density lesions in the pons and medulla. On brain MRI, T2 high signal intensity (T2-HSI) lesions with mild swelling were present in the pons, both middle cerebellar peduncles, and the anterior medulla. The initial diagnosis was viral encephalitis involving the rhombencephalon. Curiously, a cerebrospinal fluid (CSF) study revealed no cellularity, and negative viral marker findings. Three weeks later, follow up brain MRI showed that the extent of the T2-HSI lesions in the brain stem had decreased. After reinvestigation, it was found that she had a prior history of upper respiratory infection. In this case, we report the very rare case of a patient showing isolated involvement of the rhombencephalon in ADEM, mimicking viral rhombencephalitis on CT and MR imaging. ADEM can involve unusual sites such as the rhombencephalon in isolation, without involvement of the white matter or deep gray matter and, therefore, should be considered even when it appears in unusual anatomical areas. Thorough history taking is important for making a correct diagnosis.

Micro Power Properties of Harvesting Devices as a Function of PZT cantilever length and gross area (PZT 캔틸레버의 길이와 면적에 따른 에너지 하베스팅 장치의 출력 특성)

  • Kim, I.S.;Joo, H.K.;Song, J.S.;Kim, M.S.;Jeong, S.J.;Lee, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1246-1247
    • /
    • 2008
  • With recent advanced in portable electric devices, wireless sensor, MEMS and bio-Mechanics device, the new typed power supply, not conventional battery but self-powered energy source is needed. Particularly, the system that harvests from their environments are interests for use in self powered devices. For very low powered devices, environmental energy may be enough to use power source. Therefore, in other to made piezoelectric energy harvesting device, PMN-PZT thick film was formed by the screen printing method on the Ag/Pd coated alumina substrate. The layer was 8 layers and slurry where a-terpineol, ethycellulose, ferro B-75001 as Vehicle, PMN-PZT powder used are fabricated by ball mill. The output power quality was be also investigated by changing the load resistance, weight and frequency. The made piezoelectric energy harvesting device was resulted from the conditions of 33$k{\Omega}$, 0.25g, 197Hz respectively. The thick film was prepared at the condition of 2.75Vrms, and its power was 230${\mu} W$ and its thickness was 56${mu}m$. The piezoelectric energy harvesting device output voltage was increased, when the load weight, load resistance was increasing and resonance frequency was diminishing. The other side, resonance frequency was diminished, when the weight was increasing. And output power was continuously it changed by load resistance, output voltage, weight and resonance frequency.

  • PDF

Simultaneous Bilateral Quadriceps Tendon Rupture in Patient with Secondary Hyperparathyroidism due to Chronic Renal Failure: A Case Report (만성신부전증에 의한 이차성 부갑상선기능항진증 환자에서 양쪽 대퇴사두건 동시 파열: 증례 보고)

  • Shim, Jong-Joon;Shim, Jae-Chan;Ha, Jeong-Ju;Lee, Kyoung-Eun;Lee, Ghi-Jai;Kim, Ho-Kyun;Suh, Jung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.169-172
    • /
    • 2012
  • Simultaneous bilateral spontaneous rupture of the quadriceps tendon is a very rare condition and only a few cases have been reported in the literature. The etiology is not clear yet. But it occurs infrequently in patients with chronic metabolic disorders, such as secondary hyperparathyroidism due to chronic renal failure. We describe a case of simultaneous spontaneous bilateral quadriceps tendon tupture in a 36-year-old male patient with secondary hyperaprathyroidism due to chronic renal failure.

pH Effect on the Structure of Reduced NifU-like Protein from Helicobacter pylori

  • Lee, Ki-Young;Kim, Ji-Hun;Bae, Ye-Ji;Lee, Bong-Jin
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.3
    • /
    • pp.106-111
    • /
    • 2015
  • Helicobacter pylori (H. pylori) survives in acidic and fluctuating pH conditions of the stomach. The pH effect on H. pylori proteins is important for the advanced understanding of its evolution and viability, although this bacterium has the molecular machinery that neutralizes the acidic condition. HP1492 is known as a conserved NifU-like protein from H. pylori. NifU is a nitrogen fixation protein that mediates the transfer of iron-sulfur (Fe-S) cluster to iron-sulfur proteins like ferredoxin. Commonly, the monomeric reduced state of NifU can be converted to the dimeric oxidized state by intermolecular disulfide bond formation. Because it remains unclear that HP1492 actually behaves as known NifU protein, we first found that this protein can adopt both oxidized and reduced forms using size exclusion chromatography. Circular dichroism experiment showed that HP1492 is relatively well-structured at pH 6.5, compared to other pH conditions. On the basis of the backbone resonance assignment of HP1492, we further characterized the residues that are sensitive to pH using NMR spectroscopy. These residues showing large chemical shift changes could be mapped onto the secondary structure of the protein. Our results could provide the foundation for structural and biophysical studies on a wide spectrum of NifU proteins.

MR Images of Infarction of Wandering Spleen Associated with Intestinal Non-rotation (장 회전 이상과 함께 발생한 부유비장 경색의 자기공명영상에서의 소견: 증례 보고)

  • Kim, Eugene;Kim, Mi Young;Kim, Yeo Ju;Kim, Youn Jeong;Kim, Woo Chul;Suh, Chang Hae;Choi, Suk Jin;Cho, Jae Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.253-257
    • /
    • 2014
  • Wandering spleen is a rare clinical condition caused by lax splenic suspensory ligaments. The laxity of ligaments causes torsion of splenic vascular pedicle. CT scan of a 7-year-old girl with abdominal pain showed a non-enhancing lobular mass in lower abdomen. Small bowel loops were located at the right-sided abdomen and colonic loops at the left-sided abdomen. MRI scan showed non-enhancing heterogeneous mass with twisted vascular pedicle. To our knowledge, only a few cases have been reported about wandering spleen diagnosed on MRI.

The Characteristic Analysis of Thin Film Sensor using The Membrane (Membrane을 이용한 박막센서 특성 분석)

  • 이순우;김상훈;안진호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.37-41
    • /
    • 2002
  • In this research, we investigate the properties of membrane and thin film sensor which is using magnetic resonance properties. we expect to $Si_xN_y$ and SiC materials as membrane materials, we measured thin film stress and properties to find the best membrane fabrication condition. Of the two membrane, $Si_xN_y$ thin film is the better than SiC thin film. because of an adequate tensile stress and lower thermal expansion coefficient as sensor structure layer. After performing deposition and patterning thin film sensor material on $Si_xN_y$, we analyzed the magnetic hysteresis and magnetic resonance frequency of sensor. If the magnetic field which is applied in sensor material is removed, magnetization made by magnetic field is transited to elastic mode. moreover. energy radiation is induced during the transition and voltage generates in sensor by energy radiation. At this moment, If voltage generation period is longer, mechanical vibration is induced and signal is generated by mechanical vibration. we also see that as the increase of thin film sensor' length and width, magnetic resonance frequency is decreased.

  • PDF

Improvement of Pain according to Magnetic Resonance Imaging Classification in Bone Contusion around Foot and Ankle (족부 족관절 골좌상에서 자기공명영상 분류에 따른 통증의 호전)

  • Kim, Hyeong-Jik;Lee, Kwang-Bok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.183-188
    • /
    • 2019
  • Purpose: Bone contusion is usually treated with conservative therapy for 3 months. Bone contusion around knee and hip joints has been extensively reported on, but there are scant reports on this condition in foot and ankle joints. This study evaluated the nature, characteristics and location of bone contusion around foot and ankle joints to enlighten clinicians on how to better treat this disease entity. Materials and Methods: We classified bone contusion of the 76 patients into three types (102 sites; 47 ankle sprains, 18 traffic accidents, 11 falls) according to the Costa-Paz system with employing magnetic resonance imaging (MRI), and the study then analyzed the common sites and areas of occurrence according to the mechanism of injury and duration of pain after first conducting conservative therapy. Results: Of the 76 patients (102 sites) on the MRI, 43 case (42.2%) for talus, 19 cases for distal tibia, and 12 cases for calcaneus were involved. The classification, according to the Costa-Paz system, was Type I, 51 cases; Type II, 32 cases; and Type III, 19 cases. The duration of pain after conservative treatment was 12.15±2.17 weeks for Type I, 14.5±2.15 weeks for Type II, and 21.0±3.8 weeks for Type III. Conclusion: The most common location of post-traumatic bone contusion around both the foot and ankle is the talus, distal tibia, and calcaneus. The most common type of injury noted on MRI is a diffuse signal with change of the medullary component (Type I), In cases of bone contusion extending to a subjacent articular surface or disruption or depression of the normal contour of the cortical surface (Types II, III), the patients' pain appears to last longer. Thus, it is necessary to consider a longer period of conservative treatment in cases of Types II and III bone contusion because the patients' pain may last longer than 3 months.

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.3
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.