• Title/Summary/Keyword: Resonance Type

Search Result 1,096, Processing Time 0.029 seconds

Comparison of initial implant stability measured by Resonance Frequency Analysis between different implant systems (Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교)

  • Oh, Jun-Ho;Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.529-534
    • /
    • 2008
  • Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i $Osseotite^{(R)}$, Type B: $Replace^{(R)}$ select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period.

$^2D$ NMR Probe Development for Investigation of Biosupramolecular Systems

  • Kim, Andre;Kang, Shin-Won;Park, Jang-Su
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.8 no.1
    • /
    • pp.55-61
    • /
    • 2004
  • Biosupramolecular systems such as biological membranes usually fluid under physiological conditions$^1$. Therefore, solid-state NMR has been used to investigate biosupramolecular systems. But solid-state NMR spectra contain a large number of overlapping resonances and are rather difficult to analyze. These problem has to be overcome by selective isotope labeling. We constructed a deuterium NMR probe for AM400 NMR spectrometer, which is mainly used for liquid samples. To overcome the fluidity problem, a saddle type coil was designed. The efficiency was systematically investigated for two kinds of coil geometry, solenoid and saddle types. Our results suggest that solenoids are superior to saddle type coils in the sensitivity. However, the letter fits better to fluid samples such as biosupramolecular systems.

  • PDF

The analysis of the resonance characteristics of a traveling wave type ultrasonic motor by applying the normal force and driving voltage (진행파 회전형 초음파 모터의 가압력과 구동전압에 따른 공진특성의 변화 분석)

  • Oh, Jin-Heon;Park, Cheol-Hyeon;Lim, Kee-Joe;Kim, Hyeon-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.324-324
    • /
    • 2008
  • Piezoelectric ceramics is an active element that makes stator to vibrate to generate rotational force in ultrasonic motors. In drive of ultrasonic motors, many factors that affect to the resonance characteristics of piezoelectric ceramics exist. For example, those factors are bonding condition with elastic body, the magnitude of electric field, the normal force for frictional drive and the emission of heat due to vibration and friction and so on. Therefore, it is important to research the inclination of property variation of piezoelectric ceramics in circumstance that has complex elements. In this paper, we focused and analyzed the resonance characteristics of ultrasonic motor due to the magnitude of the driving voltage and normal force.

  • PDF

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

The Vibration Characteristic Analysis by Mode Variation of Ring Type Ultrasonic Motor (링형 초음파모터의 모드선정에 따른 진동특성 해석)

  • 윤신용;백수현;김현일
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.309-317
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, this paper was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], knew the fact that the vibration displacement at 0.5[mm] is an high value too. From such result, this paper was manufactured the ultrasonic motor of outer diameter 5O[mm] , inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHzl The propriety of this paper was established though comparison. investigation of simulation and experiment result.

Development of induction heating superheater system using new heat exchanging method (새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발)

  • Sul, Yong-Tae;Lee, Eui-Yong;Kwon, Hyuk-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.740-746
    • /
    • 2009
  • Two step serial load induction superheater has been proposed using resonance type induction heat method in this paper. Heat method is a type of flowing the electron induction and current to special alloy heater in body from external heat coil with non-contact method. Inverter was a full bridge serial load resonance type and inductor was used as load in LC resonance design to maximize the efficiency. The developed system is a new heat exchanging method combined with electromagnetic induction heater and fluid movement, ana very accurate to control of heating the gas, liquid and evaporated mass, so on without combustion process.

A Study on Generating Characteristics of Circular Unimorph-Type Piezoelectric Transducer (원판형 유니몰프타입 압전 트랜스듀서의 발전특성 연구)

  • Park, Choong-Hyo;Kim, Jong-Wook;Jeong, Seong-Su;Chong, Hyon-Ho;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.22-26
    • /
    • 2011
  • On this paper, a circular unimorph-type piezoelectric transducer was proposed and studied. The transducer was fabricated by attaching a circular-shaped PZT ceramic to a circular plate of brass and output characteristics of the fabricated transducer were then analyzed and measured by changing driving points where the mechanical vibrations were applied. Two conditions depending on the location of vibration were respectively defined as a center forced model and an edge forced model. The resonance frequency and output voltage of the models were simulated by using ANSYS, a FEM(finite element method) program. Based on the results of the analyses, the vibration experiment was conducted and the output characteristics then measured through measurement equipment. As a result, the maximum output characteristics of two models were respectively generated at each resonance frequency and the resonance frequency of the center forced model was lower than the edge forced model.

Development of serodiagnostic surface plasmon resonance imaging assay for the detection of antibodies to porcine circovirus type 2

  • Park, Chul;Kim, Bum-Seok;Kim, Yong-Hwan;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • A surface plasmon resonance imaging (SPRI) assay was developed for measuring porcine circovirus type 2 (PCV2) antibody using a recombinant capsid protein as an antigen. The diagnostic potential of SPRI for detecting antibodies to the PCV2 capsid protein was compared with that of a conventional enzyme-linked immunosorbent assay (ELISA) using 70 pig serum samples taken from 6 pig farms. There was a strong positive correlation between the SPRI and ELISA (n = 70, r = 0.911, P<0.01). Therefore, this recombinant capsid protein can be used as an antigen for serological studies, and the SPRI, a label-free and high-throughput method, is expected to be a valuable tool in the serodiagnosis of PCV2 infection.

Comparison of the Net Inflow Rates of Seawater Exchange Breakwater of Different Shapes (해수교환방파제의 형상별 순유입유량 특성 비교)

  • Lee, Dal-Soo;Lee, Chang-Hoon;Oh, Young-Min;Chun, In-Sik;Kim, Chang-Il
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.393-397
    • /
    • 2003
  • The seawater exchange breakwaters can be effectively employed to conserve or enhance the water quality inside harbors by transmitting the exterior water into the harbor. In the present study, three shapes of the breakwater, that is, the flow conduit embedded type, the wave chamber type and the oscillating water channel type are compared far their water exchanging capability through regular wave experiments. The results show that the net influx of water appears differently depending on wave period for each breakwater type. The net influx of the wave chamber type is much greater than that of the flow conduit embedded type. It is also ascertained that the influx of the oscillating water channel type can be greatly enhanced by attaining the resonance condition inside the channel at the wave periods frequently occurring at the fields where the breakwaters are to be installed.